Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a 60° angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student’s t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the ‘Adaptive motion’ significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.
Abstract
Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a 60° angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student’s t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the ‘Adaptive motion’ significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.
참고문헌 (21)
- Pruett JP, "Cyclic fatigue testing of nickel-titanium endodontic instruments", J Endod, 23, pp.77~85 (1997)
- Arens FC, "Evaluation of single-use rotary nickel-titanium instruments", J Endod, 29, pp.664~666 (2003)
- Berutti E, "Canal shaping with WaveOne Primary reciprocating files and ProTaper system: a comparative study", J Endod, 38, pp.505~509 (2012)
- Gambarini G, "The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment", Ann Stomatol (Roma), 4, pp.152~155 (2013)
- Giuliani V, "Efficacy of ProTaper universal retreatment files in removing filling materials during root canal retreatment", J Endod, 34, pp.1381~1384 (2008)
- Gambarini G, "In vitro analysis of efficiency and safety of a new motion for endodontic instrumentation: TF Adaptive", Roots, 3, pp.12~15 (2013)
- Higuera O, "Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals", J Endod, 41, pp.913~915 (2015)
- Li UM, "Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests", J Endod, 28, pp.448~451 (2002)
- Lopes HP, "Cyclic fatigue resistance of ProTaper Universal instruments when subjected to static and dynamic tests", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 110, pp.401~404 (2010)
- Lopes HP, "Fatigue life of Reciproc and Mtwo instruments subjected to static and dynamic tests", J Endod, 39, pp.693~696 (2013)
- Rodrigues RC, "Influence of different manufacturing methods on the cyclic fatigue of rotary nickel-titanium endodontic instruments", J Endod, 37, pp.1553~1557 (2011)
- Elnaghy AM, "Torsion and bending properties of OneShape and WaveOne instruments", J Endod, 41, pp.544~547 (2015)
- Pedullà E, "Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining", J Endod, 42, pp.156~159 (2016)
- Topçuoğlu HS, "Comparative evaluation of cyclic fatigue resistance of D‐RaCe and ProTaper retreatment instruments in curved artificial canals", Int Endod J, 49, pp.604~609 (2016)
- Inan U, "Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment", J Endod, 38, pp.108~111 (2012)
- Hussne RP, "Flexibility and torsional resistance of three nickeltitanium retreatment instrument systems", Int Endod J, 44, pp.731~738 (2011)
- Gambarini G, "Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion", Int Endod J, 45, pp.802~806 (2012)
- Gavini G, "Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement", J Endod, 38, pp.684~687 (2012)
- Shin CS, "Fatigue life enhancement of NiTi rotary endodontic instruments by progressive reciprocating operation", Int Endod J, 47, pp.882~888 (2014)
- Gambarini G, "Influence of different angles of reciprocation on the cyclic fatigue of nickel-titanium endodontic instruments", J Endod, 38, pp.1408~1411 (2012)
- De‐Deus G, "Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement", Int Endod J, 43, pp.1063~1068 (2010)
