본문 바로가기
KERD
논문KCI 등재

Effect of surface treatment on the mechanical properties of nickel-titanium files with a similar cross-section

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: The aim of this study was to compare the mechanical properties of various nickel-titanium (NiTi) files with similar tapers and cross-sectional areas depending on whether they were surface-treated. Materials and Methods: Three NiTi file systems with a similar convex triangular cross-section and the same ISO #25 tip size were selected for this study: G6 (G6), ProTaper Universal (PTU), and Dia-PT (DPT). To test torsional resistance, 5 mm of the straightened file's tip was fixed between polycarbonate blocks (n = 15/group) and continuous clockwise rotation until fracture was conducted using a customized device. To evaluate cyclic fatigue resistance, files were rotated in an artificial curved canal until fracture in a dynamic mode (n = 15/group). The torsional data were analyzed using 1-way analysis of variance and the Tukey post-hoc comparison test, while the cyclic fatigue data were analyzed using the Mann-Whitney U test at a significance level of 95%. Results: PTU showed significantly greater toughness, followed by DPT and G6 (p < 0.05). G6 showed the lowest resistance in ultimate torsional strength, while it showed a higher fracture angle than the other files (p < 0.05). In the cyclic fatigue test, DPT showed a significantly higher number of cycles to failure than PTU or G6 (p < 0.05). Conclusions: Within the limitations of this study, it can be concluded that the torsional resistance of NiTi files was affected by the cross-sectional area, while the cyclic fatigue resistance of NiTi files was influenced by the surface treatment.

Abstract

Objectives: The aim of this study was to compare the mechanical properties of various nickel-titanium (NiTi) files with similar tapers and cross-sectional areas depending on whether they were surface-treated. Materials and Methods: Three NiTi file systems with a similar convex triangular cross-section and the same ISO #25 tip size were selected for this study: G6 (G6), ProTaper Universal (PTU), and Dia-PT (DPT). To test torsional resistance, 5 mm of the straightened file's tip was fixed between polycarbonate blocks (n = 15/group) and continuous clockwise rotation until fracture was conducted using a customized device. To evaluate cyclic fatigue resistance, files were rotated in an artificial curved canal until fracture in a dynamic mode (n = 15/group). The torsional data were analyzed using 1-way analysis of variance and the Tukey post-hoc comparison test, while the cyclic fatigue data were analyzed using the Mann-Whitney U test at a significance level of 95%. Results: PTU showed significantly greater toughness, followed by DPT and G6 (p < 0.05). G6 showed the lowest resistance in ultimate torsional strength, while it showed a higher fracture angle than the other files (p < 0.05). In the cyclic fatigue test, DPT showed a significantly higher number of cycles to failure than PTU or G6 (p < 0.05). Conclusions: Within the limitations of this study, it can be concluded that the torsional resistance of NiTi files was affected by the cross-sectional area, while the cyclic fatigue resistance of NiTi files was influenced by the surface treatment.

참고문헌 (30)

  1. Schäfer E, "Comparison of hand stainless steel and nickel titanium rotary instrumentation: a clinical study", J Endod, 30, pp.432~435 (2004)
  2. Peters OA, "Current challenges and concepts in the preparation of root canal systems: a review", J Endod, 30, pp.559~567 (2004)
  3. Cheung GS, "A retrospective study of endodontic treatment outcome between nickel-titanium rotary and stainless steel hand filing techniques", J Endod, 35, pp.938~943 (2009)
  4. Sonntag D, "Root canal shaping with manual stainless steel files and rotary Ni-Ti files performed by students", Int Endod J, 36, pp.246~255 (2003)
  5. Glossen CR, "A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments", J Endod, 21, pp.146~151 (1995)
  6. Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
  7. Alapati SB, "SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use", J Endod, 31, pp.40~43 (2005)
  8. 조옥인, "Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions", Restorative Dentistry and Endodontics, 38(1), pp.31~35 (2013), 대한치과보존학회[DOI]
  9. Cheung GS, "Instrument fracture: mechanisms, removal of fragments, and clinical outcomes", Endod Topics, 16, pp.1~26 (2007)
  10. Tsujimoto M, "Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties", J Endod, 40, pp.1824~1829 (2014)
  11. Kim HC, "Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals", Int Endod J, 42, pp.593~602 (2009)
  12. Kwak SW, "Effects of pitch length and heat treatment on the mechanical properties of the glide path preparation instruments", J Endod, 42, pp.788~792 (2016)
  13. Shen Y, "Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments", J Endod, 39, pp.163~172 (2013)
  14. Kuhn G, "Influence of structure on nickel-titanium endodontic instruments failure", J Endod, 27, pp.516~520 (2001)
  15. Yum J, "Torsional strength and toughness of nickel-titanium rotary files", J Endod, 37, pp.382~386 (2011)
  16. Schneider SW, "A comparison of canal preparations in straight and curved root canals", Oral Surg Oral Med Oral Pathol, 32, pp.271~275 (1971)
  17. Pruett JP, "Cyclic fatigue testing of nickel-titanium endodontic instruments", J Endod, 23, pp.77~85 (1997)
  18. Panitvisai P, "Impact of a retained instrument on treatment outcome: a systematic review and meta-analysis", J Endod, 36, pp.775~780 (2010)
  19. McGuigan MB, "The impact of fractured endodontic instruments on treatment outcome", Br Dent J, 214, pp.285~289 (2013)
  20. Xu X, "Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections", J Endod, 32, pp.372~375 (2006)
  21. Park SY, "Dynamic torsional resistance of nickel-titanium rotary instruments", J Endod, 36, pp.1200~1204 (2010)
  22. Wycoff RC, "An in vitro comparison of torsional stress properties of three different rotary nickel-titanium files with a similar cross-sectional design", J Endod, 38, pp.1118~1120 (2012)
  23. Baek SH, "Comparison of torsional stiffness of nickel-titanium rotary files with different geometric characteristics", J Endod, 37, pp.1283~1286 (2011)
  24. Yao JH, "Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model", J Endod, 32, pp.55~57 (2006)
  25. Li UM, "Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests", J Endod, 28, pp.448~451 (2002)
  26. Ray JJ, "Cyclic fatigue of EndoSequence and K3 rotary files in a dynamic model", J Endod, 33, pp.1469~1472 (2007)
  27. Cheung GS, "Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?", J Endod, 33, pp.1217~1221 (2007)
  28. Kim HC, "Cyclic fatigue and fracture characteristics of ground and twisted nickel-titanium rotary files", J Endod, 36, pp.147~152 (2010)
  29. Kim BH, "Effect from surface treatment of nickel-titanium rotary files on the fracture resistance", Scanning, 37, pp.82~87 (2015)
  30. Anderson ME, "Fracture resistance of electropolished rotary nickel-titanium endodontic instruments", J Endod, 33, pp.1212~1216 (2007)

관련 논문AI추천

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS이윤, 금기연, 오소람, 임상민, 황수연대한치과보존학회 · Restorative Dentistry and Endodontics2009 · 제34권 제5호Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatmentKoray Yılmaz and Gülşah Uslu, Taha Özyürek대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제1호Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic filesArbab-Chirani Reza, Arbab-Chirani Shabnam, Chevalier Valérie, Gouédard Charlotte, Pino Laurent대한치과보존학회 · Restorative Dentistry and Endodontics2022 · 제47권 제2호Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro studyHadeer Mostafa El Feky, Khalid Mohammed Ezzat, Marwa Mahmoud Ali Bedier대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제4호Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvatureWafaa A. Khalil, Zuhair S. Natto대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제2호Isolating design variables by assessing the impact of cross-section geometry on the mechanical performance of nickel-titanium rotary instruments: a comparative in vitro studyAlcalde Murilo Priori, Amorim João Vitor Oliveira de, Duarte Marco Antonio Hungaro, Lima Thaine Oliveira, Neto Raimundo Sales de Oliveira, Silva Emmanuel João Nogueira Leal da, Silva Guilherme Ferreira da, Vieira Anne Rafaella Tenório, Vivan Rodrigo Ricci대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제3호