Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

In theory, the sharp dose falloff at the distal end of a proton beam allows for high conformal dose to the target. However, conformity has not been fully achieved in practice, primarily due to beam range uncertainty, which is approximately 4% and varies slightly across institutions. To address this issue, we developed a new range verification system prototype: a multi-slit prompt-gamma camera (MSPGC). This system features high prompt-gamma detection sensitivity, an advanced range estimation algorithm, and a precise camera positioning system. We evaluated the range measurement precision of the prototype for single spot beams with varying energies, proton quantities, and positions, as well as for spot-scanning proton beams in a simulated SSPT treatment using a phantom. Our results demonstrated high accuracy (<0.4 mm) in range measurement for the tested beam energies and positions. Measurement precision increased significantly with the number of protons, achieving 1% precision with 5  108 protons. For spot-scanning proton beams, the prototype ensured more than 5  108 protons per spot with a 7 mm or larger spot aggregation, achieving 1% range measurement precision. Based on these findings, we anticipate that the clinical application of the new prototype will reduce range uncertainty (currently approximately 4%) to 1% or less.

Abstract

In theory, the sharp dose falloff at the distal end of a proton beam allows for high conformal dose to the target. However, conformity has not been fully achieved in practice, primarily due to beam range uncertainty, which is approximately 4% and varies slightly across institutions. To address this issue, we developed a new range verification system prototype: a multi-slit prompt-gamma camera (MSPGC). This system features high prompt-gamma detection sensitivity, an advanced range estimation algorithm, and a precise camera positioning system. We evaluated the range measurement precision of the prototype for single spot beams with varying energies, proton quantities, and positions, as well as for spot-scanning proton beams in a simulated SSPT treatment using a phantom. Our results demonstrated high accuracy (<0.4 mm) in range measurement for the tested beam energies and positions. Measurement precision increased significantly with the number of protons, achieving 1% precision with 5  108 protons. For spot-scanning proton beams, the prototype ensured more than 5  108 protons per spot with a 7 mm or larger spot aggregation, achieving 1% range measurement precision. Based on these findings, we anticipate that the clinical application of the new prototype will reduce range uncertainty (currently approximately 4%) to 1% or less.

참고문헌 (41)

  1. Robert R. Wilson, "Radiological Use of Fast Protons", Radiology, 47(5), pp.487~491 (1946), Radiological Society of North America (RSNA)[DOI]
  2. Harald Paganetti, "Range uncertainties in proton therapy and the role of Monte Carlo simulations", Physics in Medicine and Biology, 57(11), pp.R99~R117 (2012), IOP Publishing[DOI]
  3. Albin Fredriksson, "A critical evaluation of worst case optimization methods for robust intensity‐modulated proton therapy planning", Medical Physics, 41(8Part1) (2014), Wiley[DOI]
  4. D Pflugfelder, "Worst case optimization: a method to account for uncertainties in the optimization of intensity modulated proton therapy", Physics in Medicine and Biology, 53(6), pp.1689~1700 (2008), IOP Publishing[DOI]
  5. Jan Unkelbach, "Robust radiotherapy planning", Physics in Medicine &amp; Biology, 63(22), pp.22TR02~ (2018), IOP Publishing[DOI]
  6. Jan Unkelbach, "Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning", Medical Physics, 36(1), pp.149~163 (2008), Wiley[DOI]
  7. Wei Liu, "Robust optimization of intensity modulated proton therapy", Medical Physics, 39(2), pp.1079~1091 (2012), Wiley[DOI]
  8. Antje-Christin Knopf, "<i>In vivo<", i>proton range verification: a review, 2013, pp.58(15), R131~R160[DOI]
  9. Sebastian Tattenberg, "Proton range uncertainty reduction benefits for skull base tumors in terms of normal tissue complication probability (NTCP) and healthy tissue doses", Medical Physics, 48(9), pp.5356~5366 (2021), Wiley[DOI]
  10. J. Krimmer, "Prompt-gamma monitoring in hadrontherapy: A review", Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 878, pp.58~73 (2018), Elsevier BV[DOI]
  11. F. Stichelbaut, "Verification of the proton beam position in the patient by the detection of prompt gamma rays emission", 39th Meet. Part, San Fr., pp.1~5 (2003)
  12. Chul-Hee Min, "Prompt gamma measurements for locating the dose falloff region in the proton therapy", Applied Physics Letters, 89(18), pp.2~5 (2006), AIP Publishing[DOI]
  13. M Moteabbed, "Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy", Physics in Medicine and Biology, 56(4), pp.1063~1082 (2011), IOP Publishing[DOI]
  14. Lena Nenoff, "Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification", Radiotherapy and Oncology, 125(3), pp.534~540 (2017), Elsevier BV[DOI]
  15. Yunhe Xie, "Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy", International Journal of Radiation Oncology*Biology*Physics, 99(1), pp.210~218 (2017), Elsevier BV[DOI]
  16. M Priegnitz, "Towards clinical application: prompt gamma imaging of passively scattered proton fields with a knife-edge slit camera", Physics in Medicine and Biology, 61(22), pp.7881~7905 (2016), IOP Publishing[DOI]
  17. 박종훈, "Multi-slit Prompt-gamma Camera for Locating of Distal Dose Falloff in Proton Therapy", Nuclear Engineering and Technology, 51(5), pp.1406~1416 (2019), 한국원자력학회[DOI]
  18. 김성훈, "Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy", Nuclear Engineering and Technology, 54(6), pp.2213~2220 (2022), 한국원자력학회[DOI]
  19. Chan Hyeong Kim, "Gamma electron vertex imaging and application to beam range verification in proton therapy", Medical Physics, 39(2), pp.1001~1005 (2012), Wiley[DOI]
  20. Han Rim Lee, "Prototype system for proton beam range measurement based on gamma electron vertex imaging", Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 857, pp.82~97 (2017), Elsevier BV[DOI]
  21. 김성훈, "Upgrade of gamma electron vertex imaging system for high-performance range verifi cation in pencil beam scanning proton therapy", Nuclear Engineering and Technology, 54(3), pp.1016~1023 (2022), 한국원자력학회[DOI]
  22. Chan Hyeong Kim, "Gamma electron vertex imaging for in-vivo beam-range measurement in proton therapy:experimental results", Applied Physics Letters, 113(11) (2018), AIP Publishing[DOI]
  23. F. Roellinghoff, "Design of a Compton camera for 3D prompt- imaging during ion beam therapy", Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 648, pp.S20~S23 (2011), Elsevier BV[DOI]
  24. Mirela Frandes, "A Tracking Compton-Scattering Imaging System for Hadron Therapy Monitoring", IEEE Transactions on Nuclear Science, 57(1), pp.144~150 (2010), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
  25. Jerimy C Polf, "Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification", Physics in Medicine and Biology, 60(18), pp.7085~7099 (2015), IOP Publishing[DOI]
  26. J. Krimmer, "Development of a Compton camera for medical applications based on silicon strip and scintillation detectors", Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 787, pp.98~101 (2015), Elsevier BV[DOI]
  27. Dennis Mackin, "Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy", Physics in Medicine and Biology, 57(11), pp.3537~3553 (2012), IOP Publishing[DOI]
  28. E Draeger, "3D prompt gamma imaging for proton beam range verification", Physics in Medicine &amp; Biology, 63(3), pp.035019~ (2018), IOP Publishing[DOI]
  29. Christian Richter, "First clinical application of a prompt gamma based in vivo proton range verification system", Radiotherapy and Oncology, 118(2), pp.232~237 (2016), Elsevier BV[DOI]
  30. 박종훈, "Comparison of Knife-edge and Multi-slit Camera for Proton Beam Range Verification by Monte Carlo Simulation", Nuclear Engineering and Technology, 51(2), pp.533~538 (2019), 한국원자력학회[DOI]
  31. Johannes Petzoldt, "Correction of Geometrical Effects of a Knife-Edge Slit Camera for Prompt Gamma-Based Range Verification in Proton Therapy", Instruments, 2(4), pp.25~ (2018), MDPI AG[DOI]
  32. Yafei Xing, "Improvement of Bragg peak shift estimation using dimensionality reduction techniques and predictive linear modeling" (2017)
  33. 구영모, "New algorithm to estimate proton beam range for multi-slit prompt-gamma camera", Nuclear Engineering and Technology, 54(9), pp.3422~3428 (2022), 한국원자력학회[DOI]
  34. D.A. Gedcke, "A constant fraction of pulse height trigger for optimum time resolution", Nuclear Instruments and Methods, 55, pp.377~380 (1967), Elsevier BV[DOI]
  35. Chul Hee Min, "Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy", Medical Physics, 39(4), pp.2100~2107 (2012), Wiley[DOI]
  36. Hyun Joon Choi, "Development of integrated prompt gamma imaging and positron emission tomography system for in vivo 3-D dose verification: a Monte Carlo study", Physics in Medicine &amp; Biology, 65(10), pp.105005~ (2020), IOP Publishing[DOI]
  37. Rui Zhang, "Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiation", Physics in Medicine and Biology, 54(6), pp.1383~1395 (2009), IOP Publishing[DOI]
  38. Li Zhao, "Gafchromic EBT film dosimetry in proton beams", Physics in Medicine and Biology, 55(10), pp.N291~N301 (2010), IOP Publishing[DOI]
  39. Fernando Hueso-González, "A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy", Physics in Medicine &amp; Biology, 63(18), pp.185019~ (2018), IOP Publishing[DOI]
  40. Sung Hun Kim, "Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study", 방사선방어학회지, 44(1), pp.1~7 (2019), 테스트학회[DOI]
  41. Christian Hahn, "Impact of range uncertainty on clinical distributions of linear energy transfer and biological effectiveness in proton therapy", Medical Physics, 47(12), pp.6151~6162 (2020), Wiley[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (39건)