The stochastic origin ensembles method with resolution recovery (SOE-RR) has been proposed to reconstruct proton-induced prompt gammas (PGs), and the reconstructed PG image was used for range verification. However, due to low detection efficiency, the number of valid events is low. Such a lowcount condition can degrade the accuracy of the SOE-RR method for proton range verification. In this study, we proposed two strategies to improve the reconstruction of the SOE-RR algorithm for low-count PG imaging. We also studied the number of iterations and repetitions required to achieve reliable range verification. We simulated a proton beam (108 protons) irradiated on a water phantom and used a twolayer Compton camera to detect 4.44-MeV PGs. Our simulated results show that combining the SOE-RR algorithm with restricted volume (SOE-RR-RV) can reduce the error of the estimation of the Bragg peak position from 5.0 mm to 2.5 mm. We also found that the SOE-RR-RV algorithm initialized using a backprojection image could improve the convergence rate while maintaining accurate range verification. Finally, we observed that the improved SOE-RR algorithm set for 60,000 iterations and 25 repetitions could provide reliable PG images. Based on the proposed reconstruction strategies, the SOE-RR algorithm has the potential to achieve a positioning error of 2.5 mm for low-count PG imaging.

Abstract

The stochastic origin ensembles method with resolution recovery (SOE-RR) has been proposed to reconstruct proton-induced prompt gammas (PGs), and the reconstructed PG image was used for range verification. However, due to low detection efficiency, the number of valid events is low. Such a lowcount condition can degrade the accuracy of the SOE-RR method for proton range verification. In this study, we proposed two strategies to improve the reconstruction of the SOE-RR algorithm for low-count PG imaging. We also studied the number of iterations and repetitions required to achieve reliable range verification. We simulated a proton beam (108 protons) irradiated on a water phantom and used a twolayer Compton camera to detect 4.44-MeV PGs. Our simulated results show that combining the SOE-RR algorithm with restricted volume (SOE-RR-RV) can reduce the error of the estimation of the Bragg peak position from 5.0 mm to 2.5 mm. We also found that the SOE-RR-RV algorithm initialized using a backprojection image could improve the convergence rate while maintaining accurate range verification. Finally, we observed that the improved SOE-RR algorithm set for 60,000 iterations and 25 repetitions could provide reliable PG images. Based on the proposed reconstruction strategies, the SOE-RR algorithm has the potential to achieve a positioning error of 2.5 mm for low-count PG imaging.

참고문헌 (43)

  1. J. Iwanczyk, "Radiation detection systems: Two, Volume Set" (2021), CRC Press
  2. J. C. Polf, "Prompt gamma-ray emission from biological tissues during proton irradiation : a preliminary study", Phys. Med. Biol, 54, pp.731~743 (2009)
  3. J. M. Verburg, "Proton range verification through prompt gamma-ray spectroscopy", Phys. Med. Biol, 59, pp.7089~7106 (2014)
  4. L. Kelleter, "Spectroscopic study of prompt-gamma emission for range verification in proton therapy", Phys. Med, 34, pp.7~17 (2017)
  5. 김도균, "Pinhole Camera Measurements of Prompt Gamma-rays for Detection of Beam Range Variation in Proton Therapy", Journal of the Korean Physical Society, 55(4), pp.1673~1676 (2009), 한국물리학회
  6. M. Moteabbed, "Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy", Phys. Med. Biol, 56, pp.1063~1082 (2011)
  7. J. Krimmer, "Collimated prompt gamma TOF measurements with multi-slit multidetector configurations", J. Instrum, 10, pp.P01011~ (2015)[DOI]
  8. R. W. Todd, "A proposed gamma camera", Nature, 251, pp.132~134 (1974)
  9. G. W. Phillips, "Gamma-ray imaging with Compton cameras", Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 99, pp.674~677 (1995)
  10. C. Golnik, "Range assessment in particle therapy based on prompt g-ray timing measurements", Phys. Med. Biol, 59, pp.5399~5422 (2014)
  11. J. M. Verburg, "Proton range verification through prompt gamma-ray spectroscopy", Phys. Med. Biol, 59, pp.7089~7106 (2014)
  12. J. Krimmer, "A cost-effective monitoring technique in particle therapy via uncollimated prompt gamma peak integration", Appl. Phys. Lett, 110, pp.154102~ (2017)
  13. P. Solevi, "Performance of MACACO Compton telescope for ion-beam therapy monitoring : first test with proton beams", Phys. Med. Biol, 61, pp.5149~5165 (2016)
  14. E. Mu~noz, "Performance evaluation of MACACO : a multilayer Compton camera", Phys. Med. Biol, 62, pp.7321~ (2017)
  15. S. Aldawood, "Development of a Compton camera for promptgamma medical imaging", Radiat. Phys. Chem, 140, pp.190~197 (2017)
  16. A. Koide, "Precision imaging of 4. 4 MeV gamma rays using a 3-D position sensitive Compton camera", Sci. Rep, 25, pp.8116~ (2018)
  17. I. Valencia Lozano, "Comparison of reconstructed prompt gamma emissions using maximum likelihood estimation and origin ensemble algorithms for a Compton camera system tailored to proton range monitoring", Z. Med. Phys, 22, pp.S0939~ (2022)[DOI]
  18. E. Draeger, "Feasibility studies of a new event selection method to improve spatial resolution of Compton imaging for medical applications", IEEE Trans. Radiat. Plasma Med. Sci, 1, pp.358~367 (2017)
  19. T. Ikeda, "Development of convolutional neural networks for an electron-tracking Compton camera", Prog. Theor. Exp. Phys, 2021, pp.83~84 (2021)
  20. H. M. Huang, , Phys. Med. Biol. 63 (2018)
  21. N. Kohlhase, "Capability of MLEM and OE to detect range shifts with a Compton camera in particle therapy", IEEE Trans. Radiat. Plasma Med. Sci, 4, pp.233~242 (2020)
  22. Z. Yao, "Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy", Sci. Rep, 9, pp.1133~ (2019)
  23. H. M. Huang, "Monte Carlo evaluation of a LYSO-based Compton camera using two origin ensemble algorithms with resolution recovery", Med. Phys, 48, pp.5300~5310 (2021)
  24. Z. Yao, "Rapid Compton camera imaging for source terms investigation in the nuclear decommissioning with a subsetdriven origin ensemble algorithm", Radiat. Phys. Chem, 197, pp.110133~ (2022)
  25. V. Maxim, "Probabilistic models and numerical calculation of system matrix and sensitivity in list-mode MLEM 3D reconstruction of Compton camera images", Phys. Med. Biol, 61, pp.243~264 (2016)
  26. E. Mu~noz, , Phys. Med. Biol. 63 (2018)
  27. A. Sitek, "Representation of photon limited data in emission tomography using origin ensembles", Phys. Med. Biol, 53, pp.3201~3216 (2008)
  28. A. Andreyev, "Resolution recovery for Compton camera using origin ensemble algorithm", Med. Phys, 43, pp.4866~4876 (2016)
  29. S. Agostinelli, "Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers", Detect. Assoc. Equip, 506, pp.250~303 (2003)
  30. S. Jan, "GATE : a simulation toolkit for PET and SPECT", Phys. Med. Biol, 49, pp.4543~4561 (2004)
  31. L. Grevillot, "Optimization of GEANT4 settings for proton pencil beam scanning simulations using GATE", Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 268, pp.3295~3305 (2010)
  32. F. Hueso-Gonz"alez, "Compton camera and prompt famma ray timing : two methods for in vivo range assessment in proton therapy", Front. Oncol, 6, pp.80~ (2016)
  33. M. Thiel, "High-energy photon detection with LYSO crystals", IEEE Trans. Nucl. Sci, 55, pp.1425~1429 (2008)
  34. M. Testa, "Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection", Radiat. Environ. Biophys, 49, pp.337~343 (2010)
  35. A. H. Compton, "A quantum theory of the Scattering of X-rays by light elements", Phys. Rev, 21, pp.483~502 (1923)
  36. A. Sitek, "Data analysis in emission tomography using emission-count posteriors", Phys. Med. Biol, 57, pp.6779~6795 (2012)
  37. D. MacKin, "Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy", Phys. Med. Biol, 57, pp.3537~3553 (2012)
  38. E. Draeger, , Phys. Med. Biol. 63 (2018)
  39. A. Sitek, "Reconstruction of emission tomography data using origin ensembles", IEEE Trans. Med. Imag, 30, pp.946~956 (2011)
  40. A. Zheng, "GPU accelerated stochastic origin ensemble method with list-mode data for Compton camera imaging in proton therapy", IEEE Trans. Radiat. Plasma Med. Sci, 4, pp.243~252 (2020)
  41. P. G. Ortega, "Noise evaluation of Compton camera imaging for proton therapy", Phys. Med. Biol, 60, pp.1845~1863 (2015)
  42. D. Mackin, "The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras", Med. Phys, 40, pp.12402~ (2013)
  43. E. Hilaire, "Proton therapy monitoring by Compton imaging : influence of the large energy spectrum of the prompt-g radiation", Phys. Med. Biol, 61, pp.3127~3146 (2016)

관련 논문AI추천

New algorithm to estimate proton beam range for multi-slit prompt-gamma camera구영모, 김찬형, 정재린한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제9호Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system구영모, 김성훈, 김찬형, 장세현, 정종휘, 조성구, 조재호, 최세훈한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제9호Upgrade of gamma electron vertex imaging system for high-performance range verifi cation in pencil beam scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘, 조광현, 조성구한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제3호Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy서희, 민철희, 유세환, 이현철, 천보위, 최현준한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제6호Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제6호Design of a PG-SPECT for boron concentration monitoring in BNCT at XJTUAtsushi Taketani, Dai Yuqi, Fan Jingjing, Han Zheng, Hu Yaocheng, Jiang Quanxu, Liu Kai, Liu Yongze, Wang Sheng, Yan Mingfei한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제7호

이 간행물의 다른 논문 (39건)