Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermo-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

Abstract

Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermo-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

참고문헌 (46)

  1. Neurohr AJ, "Shape-memory NiTi with two-dimensional networks of micro-channels", Acta Biomater, 7, pp.1862~1872 (2011)
  2. Frotscher M, "Achieving small structures in thin NiTi sheets for medical applications with water jet and micro machining: a comparison", J Mater Eng Perform, 20, pp.776~782 (2011)
  3. Stoeckel D, "Nitinol medical devices and implants", Minim Invasive Ther Allied Technol, 9, pp.81~88 (2000)
  4. Oshida Y, "Bioscience and bioengineering of titanium materials" (2007), Elsevier
  5. Thompson SA, "An overview of nickel-titanium alloys used in dentistry", Int Endod J, 33, pp.297~310 (2000)
  6. Peters OA, "Current challenges and concepts in the preparation of root canal systems: a review", J Endod, 30, pp.559~567 (2004)
  7. Parashos P, "Rotary NiTi instrument fracture and its consequences", J Endod, 32, pp.1031~1043 (2006)
  8. Çapar ID, "A review of instrumentation kinematics of engine-driven nickel-titanium instruments", Int Endod J, 49, pp.119~135 (2016)
  9. Yared G, "Canal preparation using only one Ni-Ti rotary instrument: preliminary observations", Int Endod J, 41, pp.339~344 (2008)
  10. Franco V, "Investigation on the shaping ability of nickel-titanium files when used with a reciprocating motion", J Endod, 37, pp.1398~1401 (2011)
  11. Bürklein S, "Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper", Int Endod J, 45, pp.449~461 (2012)
  12. Mohammadi Z, "A Review of the various surface treatments of NiTi Instruments", Iran Endod J, 9, pp.235~240 (2014)
  13. Aun DP, "Enhancement of NiTi superelastic endodontic instruments by TiO2 coating", Mater Sci Eng C, 68, pp.675~680 (2016)
  14. Lopes HP, "Influence of surface roughness on the fatigue life of nickel-titanium rotary endodontic instruments", J Endod, 42, pp.965~968 (2016)
  15. Zupanc J, "New thermomechanically treated NiTi alloys - a review", Int Endod J, 51, pp.1088~1103 (2018)
  16. Pereira ES, "Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments", Int Endod J, 45, pp.469~474 (2012)
  17. Alapati SB, "Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments", J Endod, 35, pp.1589~1593 (2009)
  18. Siu C, "An in vivo comparison of the Root ZX II, the Apex NRG XFR, and Mini Apex Locator by using rotary nickel-titanium files", J Endod, 35, pp.962~965 (2009)
  19. Kaval ME, "Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties", Clin Oral Investig, 21, pp.1527~1530 (2017)
  20. Serafin M, "In vitro comparison of cyclic fatigue resistance of two rotary single-file endodontic systems: OneCurve versus OneShape", Odontology, 107, pp.196~201 (2019)
  21. Shen Y, "HyFlex nickel-titanium rotary instruments after clinical use: metallurgical properties", Int Endod J, 46, pp.720~729 (2013)
  22. Ninan E, "Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments", J Endod, 39, pp.101~104 (2013)
  23. Topçuoğlu HS, "In vitro comparison of cyclic fatigue resistance of ProTaper Next, HyFlex CM, OneShape, and ProTaper universal instruments in a canal with a double curvature", J Endod, 42, pp.969~971 (2016)
  24. Tobushi H, "Low-cycle fatigue of Ni-Ti shape memory alloy and formulation of fatigue life", J Eng Mater Technol, 122, pp.186~191 (2000)
  25. Shen Y, "Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments", J Endod, 38, pp.376~380 (2012)
  26. Vadhana S, "Cyclic fatigue resistance of RaCe and Mtwo rotary files in continuous rotation and reciprocating motion", J Endod, 40, pp.995~999 (2014)
  27. Grande NM, "Cyclic fatigue resistance and threedimensional analysis of instruments from two nickel-titanium rotary systems", Int Endod J, 39, pp.755~763 (2006)
  28. La Rosa GR, "Influence of surrounding temperature and angle of file access on cyclic fatigue resistance of two single file nickel-titanium instruments", Aust Endod J, 47, pp.260~264 (2021)
  29. Rubio J, "A comparative study of cyclic fatigue of 10 different types of endodontic instruments: an in vitro study", Acta Stomatol Croat, 53, pp.28~36 (2019)
  30. Cheung GS, "A numerical method for predicting the bending fatigue life of NiTi and stainless steel root canal instruments", Int Endod J, 44, pp.357~361 (2011)
  31. Capar ID, "Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments", Aust Endod J, 41, pp.24~28 (2015)
  32. Elnaghy AM, "Cyclic fatigue resistance of One Curve, 2Shape, ProFile Vortex, Vortex Blue, and RaCe nickel-titanium rotary instruments in single and double curvature canals", J Endod, 44, pp.1725~1730 (2018)
  33. Ye J, "Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue", J Endod, 38, pp.105~107 (2012)
  34. Shen Y, "Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments", J Endod, 37, pp.1566~1571 (2011)
  35. Iacono F, "Structural analysis of HyFlex EDM instruments", Int Endod J, 50, pp.303~313 (2017)
  36. Testarelli L, "Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel", J Endod, 37, pp.1293~1295 (2011)
  37. Pongione G, "Flexibility and resistance to cyclic fatigue of endodontic instruments made with different nickel-titanium alloys: a comparative test", Ann Stomatol (Roma), 3, pp.119~122 (2012)
  38. Santos LA, "Comparison of the mechanical behavior between controlled memory and superelastic nickel-titanium files via finite element analysis", J Endod, 39, pp.1444~1447 (2013)
  39. Pereira ES, "Behavior of nickel-titanium instruments manufactured with different thermal treatments", J Endod, 41, pp.67~71 (2015)
  40. Goo HJ, "Mechanical properties of various heat-treated nickeltitanium rotary instruments", J Endod, 43, pp.1872~1877 (2017)
  41. Soares RG, "Comparative study of the mechanical properties of instruments made of conventional, M-wire, R-phase, and controlled memory nickel-titanium alloys", ENDO, 11, pp.271~277 (2017)
  42. Zhou HM, "Mechanical properties of controlled memory and superelastic nickel-titanium wires used in the manufacture of rotary endodontic instruments", J Endod, 38, pp.1535~1540 (2012)
  43. Capar ID, "Comparison of the cyclic fatigue resistance of 5 different rotary pathfinding instruments made of conventional nickel-titanium wire, M-wire, and controlled memory wire", J Endod, 41, pp.535~538 (2015)
  44. Pedullà E, "Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments", Int Endod J, 48, pp.1043~1050 (2015)
  45. Palma PJ, "Cyclic fatigue resistance of three rotary file systems in a dynamic model after immersion in sodium hypochlorite", Odontology, 107, pp.324~332 (2019)
  46. Topçuoğlu HS, "Effect of two different temperatures on resistance to cyclic fatigue of one Curve, EdgeFile, HyFlex CM and ProTaper next files", Aust Endod J, 46, pp.68~72 (2020)

관련 논문AI추천

Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperatureGündoğar Mustafa, Özyürek Taha, Plotino Gianluca, Uslu Gülşah대한치과보존학회 · Restorative Dentistry and Endodontics2020 · 제45권 제3호In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canalsGülşah Uslu, Koray Yılmaz, Taha Özyürek대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제4호Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro studyHadeer Mostafa El Feky, Khalid Mohammed Ezzat, Marwa Mahmoud Ali Bedier대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제4호Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvatureWafaa A. Khalil, Zuhair S. Natto대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제2호EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS이윤, 금기연, 오소람, 임상민, 황수연대한치과보존학회 · Restorative Dentistry and Endodontics2009 · 제34권 제5호Effect of surface treatment on the mechanical properties of nickel-titanium files with a similar cross-section곽상원, 구혜진, 김현철, 이주영대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제3호