본문 바로가기
KERD
논문KCI 등재

Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. Methods: Four types of ceramic (one with a stainless steel slot) and one conventional stainless steel bracket were tested with two types of archwire sizes: a 0.017 × 0.025-in wire in the 0.018-in slots and a 0.019 × 0.025-in wire in the 0.022-in slot brackets. For pairwise comparisons between the 0.018-in and 0.022-in slot sizes in the same bracket, an independent sample t-test was used. One-way and two-way analysis of variance (ANOVA) and Tukey’s post-hoc test at the 95% confidence level (α = 0.05) were also used for statistical analyses. Results: There were significant differences between the 0.022-in and 0.018-in slot sizes for the same brand of bracket. ANOVA also showed that both slot size and bracket slot material had significant effects on COF values (p < 0.001). The ceramic bracket with a 0.022-in stainless steel slot showed the lowest mean COF (m = 0.18), followed by the conventional stainless steel bracket with a 0.022-in slot (m = 0.21). The monocrystalline alumina ceramic bracket with a 0.018-in slot had the highest COF (m = 0.85). Conclusions: Brackets with stainless steel slots exhibit lower COFs than ceramic slot brackets. All brackets show lower COFs as the slot size increases. [Korean J Orthod 2015;45(1):29-37]

Abstract

Objective: The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. Methods: Four types of ceramic (one with a stainless steel slot) and one conventional stainless steel bracket were tested with two types of archwire sizes: a 0.017 × 0.025-in wire in the 0.018-in slots and a 0.019 × 0.025-in wire in the 0.022-in slot brackets. For pairwise comparisons between the 0.018-in and 0.022-in slot sizes in the same bracket, an independent sample t-test was used. One-way and two-way analysis of variance (ANOVA) and Tukey’s post-hoc test at the 95% confidence level (α = 0.05) were also used for statistical analyses. Results: There were significant differences between the 0.022-in and 0.018-in slot sizes for the same brand of bracket. ANOVA also showed that both slot size and bracket slot material had significant effects on COF values (p < 0.001). The ceramic bracket with a 0.022-in stainless steel slot showed the lowest mean COF (m = 0.18), followed by the conventional stainless steel bracket with a 0.022-in slot (m = 0.21). The monocrystalline alumina ceramic bracket with a 0.018-in slot had the highest COF (m = 0.85). Conclusions: Brackets with stainless steel slots exhibit lower COFs than ceramic slot brackets. All brackets show lower COFs as the slot size increases. [Korean J Orthod 2015;45(1):29-37]

참고문헌 (29)

  1. Frank CA, "A comparative study of frictional resistances between orthodontic bracket and arch wire", Am J Orthod, 78, pp.593~609 (1980)
  2. Braun S, "Friction in perspective", Am J Orthod Dentofacial Orthop, 115, pp.619~627 (1999)
  3. Cacciafesta V, "Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations", Am J Orthod Dentofacial Orthop, 124, pp.395~402 (2003)
  4. Drescher D, "Frictional forces between bracket and arch wire", Am J Orthod Dentofacial Orthop, 96, pp.397~404 (1989)
  5. Read-Ward GE, "A comparison of self-ligating and conventional orthodontic bracket systems", Br J Orthod, 24, pp.309~317 (1997)
  6. Kusy RP, "Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states", Angle Orthod, 61, pp.293~302 (1991)
  7. Kusy RP, "Effects of sliding velocity on the coefficients of friction in a model orthodontic system", Dent Mater, 5, pp.235~240 (1989)
  8. Saunders CR, "Surface topography and frictional characteristics of ceramic brackets", Am J Orthod Dentofacial Orthop, 106, pp.76~87 (1994)
  9. Stannard JG, "Comparative friction of orthodontic wires under dry and wet conditions", Am J Orthod, 89, pp.485~491 (1986)
  10. Willems G, "Frictional behavior of stainless steel bracket-wire combinations subjected to small oscillating displacements", Am J Orthod Dentofacial Orthop, 120, pp.371~377 (2001)
  11. Clocheret K, "Dynamic frictional behaviour of orthodontic archwires and brackets", Eur J Orthod, 26, pp.163~170 (2004)
  12. Kusy RP, "Influence of fluid media on the frictional coefficients in orthodontic sliding", Semin Orthod, 9, pp.281~289 (2003)
  13. Kusy RP, "Friction between different wire-bracket configurations and materials", Semin Orthod, 3, pp.166~177 (1997)
  14. Zinelis S, "Comparative assessment of the roughness, hardness, and wear resistance of aesthetic bracket materials", Dent Mater, 21, pp.890~894 (2005)
  15. Bazakidou E, "Evaluation of frictional resistance in esthetic brackets", Am J Orthod Dentofacial Orthop, 112, pp.138~144 (1997)
  16. Cha JY, "Friction of conventional and silica-insert ceramic brackets in various bracketwire combinations", Angle Orthod, 77, pp.100~107 (2007)
  17. Reicheneder CA, "Frictional properties of aesthetic brackets", Eur J Orthod, 29, pp.359~365 (2007)
  18. Cacciafesta V, "Evaluation of friction of conventional and metal-insert ceramic brackets in various bracketarchwire combinations", Am J Orthod Dentofacial Orthop, 124, pp.403~409 (2003)
  19. Pizzoni L, "Frictional forces related to self-ligating brackets", Eur J Orthod, 20, pp.283~291 (1998)
  20. Franchi L, "Maxillary arch changes during leveling and aligning with fixed appliances and low-friction ligatures", Am J Orthod Dentofacial Orthop, 130, pp.88~91 (2006)
  21. Pratten DH, "Frictional resistance of ceramic and stainless steel orthodontic brackets", Am J Orthod Dentofacial Orthop, 98, pp.398~403 (1990)
  22. Kapur R, "Frictional resistance in orthodontic brackets with repeated use", Am J Orthod Dentofacial Orthop, 116, pp.400~404 (1999)
  23. Russell JS., "Aesthetic orthodontic brackets", J Orthod, 32, pp.146~163 (2005)
  24. Kusy RP, "Frictional resistances of metallined ceramic brackets versus conventional stainless steel brackets and development of 3-D friction maps", Angle Orthod, 71, pp.71~364 (2001)
  25. De Franco DJ, "Frictional resistances using Teflon-coated ligatures with various bracket-archwire combinations", Angle Orthod, 65, pp.63~72 (1995)
  26. Omana HM, "Frictional properties of metal and ceramic brackets", J Clin Orthod, 26, pp.425~432 (1992)
  27. Burrow SJ, "Friction and resistance to sliding in orthodontics: a critical review", Am J Orthod Dentofacial Orthop, 135, pp.442~447 (2009)
  28. Rock WP, "The effect of bracket type and ligation method upon forces exerted by orthodontic archwires", Br J Orthod, 16, pp.213~217 (1989)
  29. Kusy RP, "Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding", Eur J Orthod, 21, pp.199~208 (1999)

관련 논문AI추천

A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type황충주, Souk Min Lee대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제1호Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets김윤미, 유형석, 차정열, 황충주, Seon Gun Tahk대한치과교정학회 · 대한치과교정학회지2014 · 제44권 제4호세라믹 브라켓의 종류 및 브라켓 슬롯과 와이어 각도에 따른 마찰 저항 차이박영철, 최윤정대한치과교정학회 · 대한치과교정학회지2006 · 제36권 제3호Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical studyBum-Soon Lim, Do-Yoon Kim, Seung-Hak Baek대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제2호Effect of passive self-ligating bracket placement on the posterior teeth on reduction of frictional force in sliding mechanicsKyu-Ry Kim, Seung-Hak Baek대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제2호In -vitro investigation of the mechanical friction properties of a computer-aided design and computer-aided manufacturing lingual bracket system under diverse tooth displacement conditionDo-Yoon Kim, Il-Hyung Yang, Il-Sik Cho, Sang-Woon Ha, Seung-Hak Baek대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제2호

이 간행물의 다른 논문 (6건)