Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CLLBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXLI); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at 36.5oC. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the In-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXLI. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXLI in all brackets (all p < 0.001). Conclusions: CLLBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage. [Korean J Orthod 2016;46(2):87-95]
Abstract
Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CLLBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXLI); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at 36.5oC. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the In-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXLI. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXLI in all brackets (all p < 0.001). Conclusions: CLLBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage. [Korean J Orthod 2016;46(2):87-95]
참고문헌 (23)
- Fujita K, "New orthodontic treatment with lingual bracket mushroom arch wire appliance", Am J Orthod, 76, pp.657~675 (1979)
- Smith JR, "Keys to success in lingual therapy. Part 1", J Clin Orthod, 20, pp.252~261 (1986)
- Creekmore T, "Lingual orthodontics--its renaissance", Am J Orthod Dentofacial Orthop, 96, pp.120~137 (1989)
- Moran KI, "Relative wire stiffness due to lingual versus labial interbracket distance", Am J Orthod Dentofacial Orthop, 92, pp.24~32 (1987)
- Takemoto K, "Lingual orthodontics extraction therapy", Clin Impr, 4, pp.2~21 (1995)
- Geron S, "Finishing with lingual appliances, problems and solutions", Semin Orthod, 12, pp.191~202 (2006)
- Lombardo L, "Wire load-deflection characteristics relative to different types of brackets", Int Orthod, 9, pp.120~139 (2011)
- Khattab TZ, "Speech performance and oral impairments with lingual and labial orthodontic appliances in the first stage of fixed treatment", Angle Orthod, 83, pp.519~526 (2013)
- Kyung Hee Park, "New classification of lingual arch form in normal occlusion using three dimensional virtual models", 대한치과교정학회지, 45(2), pp.74~81 (2015), 대한치과교정학회
- Kusy RP, "Resistance to sliding of orthodontic appliances in the dry and wet states:influence of archwire alloy, interbracket distance, and bracket engagement", J Biomed Mater Res, 52, pp.797~811 (2000)
- Kim TK, "Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont system", Am J Orthod Dentofacial Orthop, 187, pp.187.e15~187.e24 (2008)
- Heo W, "Friction properties according to vertical and horizontal tooth displacement and bracket type during initial leveling and alignment", Angle Orthod, 81, pp.653~661 (2011)
- Lombardo L, "Frictional resistance exerted by different lingual and labial brackets: an in vitro study", Prog Orthod, 14, pp.37~ (2013)
- Mevlut Celikoglu, "Mandibular changes during initial alignment with SmartClip self-ligating and conventional brackets: A single-center prospective randomized controlled clinical trial", 대한치과교정학회지, 45(2), pp.89~94 (2015), 대한치과교정학회
- Henao SP, "Evaluation of the frictional resistance of conventional and self-ligating bracket designs using standardized archwires and dental typodonts", Angle Orthod, 74, pp.202~211 (2004)
- Henao SP, "Frictional evaluations of dental typodont models using four self-ligating designs and a conventional design", Angle Orthod, 75, pp.75~85 (2005)
- Seo YJ, "Effect of self-ligating bracket type and vibration on frictional force and stick-slip phenomenon in diverse tooth displacement conditions: an in vitro mechanical analysis", Eur J Orthod, 37, pp.474~480 (2015)
- Seo YJ, "Effect of tooth displacement and vibration on frictional force and stick-slip phenomenon in conventional brackets: a preliminary in vitro mechanical analysis", Eur J Orthod, 37, pp.158~163 (2015)
- Park JH, "Frictional forces between lingual brackets and archwires measured by a friction tester", Angle Orthod, 74, pp.816~824 (2004)
- Ozturk Ortan Y, "A comparative in vitro study of frictional resistance between lingual brackets and stainless steel archwires", Eur J Orthod, 34, pp.119~125 (2012)
- Scuzzo G, "A new lingual straight-wire technique", J Clin Orthod, 44, pp.114~123 (2010)
- Scuzzo G, "A new self-ligating lingual bracket with square slots", J Clin Orthod, 45, pp.682~690 (2011)
- Xia Z, "Biomechanical validation of an artificial tooth-periodontal ligament-bone complex for in vitro orthodontic load measurement", Angle Orthod, 83, pp.410~417 (2013)