본문 바로가기
KERD
논문KCI 등재

Effect of passive self-ligating bracket placement on the posterior teeth on reduction of frictional force in sliding mechanics

4

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: The purpose of this study was to investigate the static (SFF) and kinetic frictional forces (KFF) in sliding mechanics of hybrid bracket systems that involve placing a conventional bracket (CB) or active self-ligating bracket (ASLB) on the maxillary anterior teeth (MXAT) and a passive SLB (PSLB) on the maxillary posterior teeth (MXPT). Methods: The samples consisted of two thoroughbred types (group 1, anterior-CB + posterior-CB; group 2, anterior-ASLB + posterior-ASLB) and four hybrid types (group 3, anterior-CB + posterior-PSLBtype 1; group 4, anterior-CB + posterior-PSLB-type 2; group 5, anterior-ASLB + posterior-PSLB-type 1; group 6, anterior-ASLB + posterior-PSLB-type 2) (n = 13 per group). After maxillary dentition alignment and maxillary first premolars removal in the stereolithographically-made typodont system, a 0.019 × 0.025-inch stainless steel wire was drawn through the right quadrant of the maxillary arch at 0.5 mm/min for 5 min. The SFF and KFF were measured with a mechanical testing machine and statistical analyses were performed. Results: Four different categories of SFF and KFF were observed among all groups (all p < 0.001). Group 1 demonstrated the highest SFF and KFF; groups 4 and 3 were second and third highest, respectively. The fourth category included groups 2, 5, and 6. Placing PSLBs on the MXPT resulted in significant SFF and KFF reductions in cases with CBs on the MXAT, but not in cases with ASLBs on the MXAT. Conclusions: These data might aid in the development of a hybrid bracket system that enables low-friction sliding of an archwire through the MXPT.[Korean J Orthod 2016;46(2):73-80]

Abstract

Objective: The purpose of this study was to investigate the static (SFF) and kinetic frictional forces (KFF) in sliding mechanics of hybrid bracket systems that involve placing a conventional bracket (CB) or active self-ligating bracket (ASLB) on the maxillary anterior teeth (MXAT) and a passive SLB (PSLB) on the maxillary posterior teeth (MXPT). Methods: The samples consisted of two thoroughbred types (group 1, anterior-CB + posterior-CB; group 2, anterior-ASLB + posterior-ASLB) and four hybrid types (group 3, anterior-CB + posterior-PSLBtype 1; group 4, anterior-CB + posterior-PSLB-type 2; group 5, anterior-ASLB + posterior-PSLB-type 1; group 6, anterior-ASLB + posterior-PSLB-type 2) (n = 13 per group). After maxillary dentition alignment and maxillary first premolars removal in the stereolithographically-made typodont system, a 0.019 × 0.025-inch stainless steel wire was drawn through the right quadrant of the maxillary arch at 0.5 mm/min for 5 min. The SFF and KFF were measured with a mechanical testing machine and statistical analyses were performed. Results: Four different categories of SFF and KFF were observed among all groups (all p < 0.001). Group 1 demonstrated the highest SFF and KFF; groups 4 and 3 were second and third highest, respectively. The fourth category included groups 2, 5, and 6. Placing PSLBs on the MXPT resulted in significant SFF and KFF reductions in cases with CBs on the MXAT, but not in cases with ASLBs on the MXAT. Conclusions: These data might aid in the development of a hybrid bracket system that enables low-friction sliding of an archwire through the MXPT.[Korean J Orthod 2016;46(2):73-80]

참고문헌 (31)

  1. Frank CA, "A comparative study of frictional resistances between orthodontic bracket and arch wire", Am J Orthod, 78, pp.593~609 (1980)
  2. Nursel Arici, "Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique", 대한치과교정학회지, 45(1), pp.29~37 (2015), 대한치과교정학회
  3. Shivapuja PK, "A comparative study of conventional ligation and self-ligation bracket systems", Am J Orthod Dentofacial Orthop, 106, pp.472~480 (1994)
  4. Budd S, "A study of the frictional characteristics of four commercially available self-ligating bracket systems", Eur J Orthod, 30, pp.645~653 (2008)
  5. Kim TK, "Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont system", Am J Orthod Dentofacial Orthop, 133, pp.187.e15~187.e24 (2008)
  6. Krishnan M, "Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys", Am J Orthod Dentofacial Orthop, 136, pp.675~682 (2009)
  7. Cordasco G, "In vitro evaluation of the frictional forces between brackets and archwire with three passive self-ligating brackets", Eur J Orthod, 31, pp.643~646 (2009)
  8. Souk Min Lee, "A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type", 대한치과교정학회지, 45(1), pp.13~19 (2015), 대한치과교정학회
  9. Heo W, "Friction properties according to vertical and horizontal tooth displacement and bracket type during initial leveling and alignment", Angle Orthod, 81, pp.653~661 (2011)
  10. Brauchli LM, "Active and passive self-ligation-a myth?", Angle Orthod, 81, pp.312~318 (2011)
  11. Huang TH, "An in vitro comparison of the frictional forces between archwires and self-ligating brackets of passive and active types", Eur J Orthod, 34, pp.625~632 (2012)
  12. Pizzoni L, "Frictional forces related to self-ligating brackets", Eur J Orthod, 20, pp.283~291 (1998)
  13. Thorstenson GA, "Resistance to sliding of orthodontic brackets with bumps in the slot floors and walls: effects of second-order angulation", Dent Mater, 20, pp.881~892 (2004)
  14. Hain M, "A comparison of different ligation methods on friction", Am J Orthod Dentofacial Orthop, 130, pp.666~670 (2006)
  15. Stefanos S, "Friction between various self-ligating brackets and archwire couples during sliding mechanics", Am J Orthod Dentofacial Orthop, 138, pp.463~467 (2010)
  16. Badawi HM, "Torque expression of self-ligating brackets", Am J Orthod Dentofacial Orthop, 133, pp.721~728 (2008)
  17. Rinchuse DJ, "Self-ligating brackets:present and future", Am J Orthod Dentofacial Orthop, 132, pp.216~222 (2007)
  18. Paik CH, "Low-friction space closure with a hybrid bracket-tube system", J Clin Orthod, 44, pp.622~627 (2010)
  19. Seo YJ, "Effect of tooth displacement and vibration on frictional force and stick-slip phenomenon in conventional brackets: a preliminary in vitro mechanical analysis", Eur J Orthod, 37, pp.158~163 (2015)
  20. Nakago T, "Determination of the tooth mobility change during the orthodontic tooth movement studied by means of Periotest and MIMD (the mechanical impedance measuring device for the periodontal tissue)", Am J Orthod Dentofacial Orthop, 105, pp.92~96 (1994)
  21. Tanaka E, "Longitudinal measurements of tooth mobility during orthodontic treatment using a periotest", Angle Orthod, 75, pp.101~105 (2005)
  22. Henao SP, "Evaluation of the frictional resistance of conventional and self-ligating bracket designs using standardized archwires and dental typodonts", Angle Orthod, 74, pp.202~211 (2004)
  23. Andrews LF, "The six keys to normal occlusion", Am J Orthod, 62, pp.296~309 (1972)
  24. Henao SP, "Frictional evaluations of dental typodont models using four self-ligating designs and a conventional design", Angle Orthod, 75, pp.75~85 (2005)
  25. Ehsani S, "Frictional resistance in self-ligating orthodontic brackets and conventionally ligated brackets. A systematic review", Angle Orthod, 79, pp.592~601 (2009)
  26. Franchi L, "Forces released during sliding mechanics with passive self-ligating brackets or nonconventional elastomeric ligatures", Am J Orthod Dentofacial Orthop, 133, pp.87~90 (2008)
  27. Major TW, "Mechanical effects of third-order movement in self-ligated brackets by the measurement of torque expression", Am J Orthod Dentofacial Orthop, 139, pp.e31~e44 (2011)
  28. Brauchli LM, "Active and passive self-ligation: a myth? Part 1: torque control", Angle Orthod, 82, pp.663~669 (2012)
  29. Chung M, "Thirdorder torque and self-ligating orthodontic brackettype effects on sliding friction", Angle Orthod, 79, pp.551~557 (2009)
  30. Tecco S, "Evaluation of the friction of self-ligating and conventional bracket systems", Eur J Dent, 5, pp.310~317 (2011)
  31. Oliver CL, "Archwire depth is a significant parameter in the frictional resistance of active and interactive, but not passive, self-ligating brackets", Angle Orthod, 81, pp.1036~1044 (2011)

관련 논문AI추천

A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type황충주, Souk Min Lee대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제1호Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical studyBum-Soon Lim, Do-Yoon Kim, Seung-Hak Baek대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제2호Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro studyBing Han, Huizhong Chen, Tianmin Xu대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제1호In -vitro investigation of the mechanical friction properties of a computer-aided design and computer-aided manufacturing lingual bracket system under diverse tooth displacement conditionDo-Yoon Kim, Il-Hyung Yang, Il-Sik Cho, Sang-Woon Ha, Seung-Hak Baek대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제2호In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignmentAngela Militi, Antonino Lo Giudice, Giancarlo Cordasco, Giovanni Matarese, Giuseppe Triolo, Riccardo Nucera대한치과교정학회 · 대한치과교정학회지2012 · 제42권 제4호Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro techniqueBerat Serdar Akdeniz, Nursel Arici, Selim Arici대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제1호

이 간행물의 다른 논문 (7건)