본문 바로가기
KERD
논문KCI 등재

Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation

Abstract

Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation

참고문헌 (18)

  1. V. Favaudon, "Ultra high dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice", Sci. Transl. Med, 16, pp.1~9 (2014)
  2. P. Montay-Gruel, "Irradiation in a flash : unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy", s, 2017, pp.124, 365~369
  3. J. Bourhis, "Treatment of a first patient with FLASH-radiotherapy", Radiother. Oncol, 139, pp.18~22 (2019)
  4. E. Schuler, "Experimental platform for ultra-high dose rate FLASH irradiation of small animals using a clinical linear accelerator", Int. J. Radiat. Oncol. Biol. Phys, 97, pp.195~203 (2017)
  5. M. Lempart, "Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiation", Radiother. Oncol, 139, pp.40~45 (2019)
  6. L. G. Marcu, "Translational research in FLASH radiotherapydfrom radiobiological mechanisms to in vivo results", Biomedicines, 9, pp.1~15 (2021)
  7. H. Lim, "Implementation of ultra-high dose-rate electron beam from 6-MeV C-band linear accelerator for preclinical study", J. Instrum, 15, pp.P09013~ (2020)
  8. K. Petersson, "High dose-per-pulse electron beam dosimetryda model to correct for the ion recombination in the Advanced Markus ionization chamber", Med. Phys, 44, pp.1157~1167 (2017)
  9. J. W. Boag, "The effect of free-electron collection on the recombination correction to ionization measurements of pulsed radiation", Phys. Med. Biol, 41, pp.885~897 (1996)
  10. R. F. Laitano, "Charge collection efficiency in ionization chambers exposed to electron beams with high dose per pulse", Phys. Med. Biol, 51, pp.6419~6436 (2006)
  11. 정동혁, "High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved IonRecombination Corrections", 의학물리, 31(4), pp.145~152 (2020), 한국의학물리학회[DOI]
  12. T. C. Zhu, "Characteristics of bremsstrahlung in electron beams", Med. Phys, 28, pp.1352~1358 (2001)
  13. F.H. Attix, "Introduction to Radiological Physics and Radiation Dosimetry", pp.177~178 (1986), John Wiley & Sons, Inc
  14. 정동혁, "Electron beam scattering device for FLASH preclinical studies with 6-MeV LINAC", Nuclear Engineering and Technology, 53(4), pp.1289~1296 (2021), 한국원자력학회[DOI]
  15. Absorbed Dose Determination in External Beam Radiotherapy: an International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water, "P. Andreo", International Atomic Energy Agency, 150~151, pp.IAEA TRS-398 (2006)
  16. F.M. Khan, "The Physics of Radiation Therapy", pp.106~155, Lippincott Williams and Wilkins
  17. Elsa Y. Leon Marroquin, "Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density", J. Appl. Clin. Med. Phys, 17, pp.466~481 (2016)

관련 논문AI추천

Characterization of real-time dose measurement using monitor ionization chamber in electron beam FLASH radiotherapyHu Zhenguo, Lang Xinle, Li Juan, Li Min, Luo Faming, Mao Ruishi, Xiao Guoqing, Xu Zhiguo, Zhou Kai한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제6호Robust dosimetric evaluation of FLASH proton beams using plane-parallel ionization chambers and EBT-XD films for pre-clinical studies박희철, 안성환, 전찬일, 조성구, 최창훈, 한영이, Amano Daizo, Heesoon Sheen, Kamiguchi Nagaaki한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제11호Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry김인중, 박종인, Okky Agassy F.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제4호Upgrade of gamma electron vertex imaging system for high-performance range verifi cation in pencil beam scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘, 조광현, 조성구한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제3호Monte Carlo simulation of absorbed dose in water for the INTRABEAM electronic brachytherapy unit using a micro-diamond detector modelMalidarreh Roya Boudaghi, Zakaly Hesham M.H.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호Validation of electromagnetic physics models and electron range in Geant4 Brachytherapy applicationAbabneh E., Albqoor A., Okoor S., Zahran I.한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제1호

이 간행물의 다른 논문 (39건)