The mechanics underlying photon and electron interactions was validated using our developed Brachytherapy computer code for high Dose Rate (HDR). By comparing the photon cross-section utilizing multiple physics libraries in the developed code, the results were benchmarked against experimental and theoretical findings. Klein-Nishina and experimental cross-section results were in good agreement with the Livermore library results. For two therapeutically relevant materials, the first scattered electron range was measured within 1 mm and 2 mm, which has significant implications for the interpretation of the kernel dose spikes observed in previous research.

Abstract

The mechanics underlying photon and electron interactions was validated using our developed Brachytherapy computer code for high Dose Rate (HDR). By comparing the photon cross-section utilizing multiple physics libraries in the developed code, the results were benchmarked against experimental and theoretical findings. Klein-Nishina and experimental cross-section results were in good agreement with the Livermore library results. For two therapeutically relevant materials, the first scattered electron range was measured within 1 mm and 2 mm, which has significant implications for the interpretation of the kernel dose spikes observed in previous research.

참고문헌 (17)

  1. S. Agostinelli, "GEANT4da simulation toolkit", Nucl. Instr. Meth. A, 506(3), pp.250~303 (2003)
  2. M.P.W. Chin, "Non-convergence of Geant4 hadronic models for 10 and 30MeV protons in 18O and 14N", Applied Radiation and Isotopes, 67(3), pp.406~414 (2009), Elsevier BV[DOI]
  3. E. Ababneh, "Enhancement and validation of Geant4 Brachytherapy application on clinical HDR 192Ir source", Radiat, Phys. Chem, 103, pp.57~66 (2014)
  4. E. Ababneh, "Physics elements of an algorithm for brachytherapy dose calculation in homogeneous media for 192Ir source", Radiat. Phys. Chem, 149, pp.90~103 (2018)
  5. S. INCERTI, "THE GEANT4-DNA PROJECT", International Journal of Modeling, Simulation, and Scientific Computing, 01(02), pp.157~178 (2010), World Scientific Pub Co Pte Lt[DOI]
  6. "Geant4"[URL]
  7. V. Ivanchenko, "Recent improvements in geant4 electromagnetic physics models and interfaces", J. Nucl. Sci. Technol, 2, pp.898~903 (2011)
  8. H. Burkhardt, "Geant4 standard electromagnetic package for HEP applications", IEEE Nucl. Sci. Symp. Conf. Rec, 3, pp.1907~1910 (2004)
  9. Katsuya. Amako, "Comparison of Geant4 electromagnetic physics models against the NIST reference data", IEEE Trans. Nucl. Sci, 52, pp.910~918 (2005)
  10. P. A. G. Cirrone, "Validation of the Geant4 electromagnetic photon cross-sections for elements and compounds", Nucl. Instr. Meth. A, 618, pp.315~322 (2010)
  11. Yakup Kurucu, "Incoherent scattering cross-sections for elements with 23 ≤ Z ≤ 51 at 59.5keV photon energy", Journal of Electron Spectroscopy and Related Phenomena, 142(1), pp.39~43 (2005), Elsevier BV[DOI]
  12. M.C. Martins, "A Comparison between GEANT4 and MCNPX on the Dosimetry of the 192Ir MicroSelectron V2 HDR Brachytherapy", International Nuclear Atlantic Conference - INAC 2011 (2011)
  13. F. Ballester, "A generic high dose rate 192Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism", Med. Phys, 42, pp.3048~3062 (2015)
  14. "ROOT"[URL]
  15. J. E. Turner, "Atoms, Radiation, and Radiation Protection" (1995), Wiley
  16. "NIST"[URL]
  17. D.E. Cullen, "The evaluated photon data library’ 997version", UCRL, 6 (1997)

관련 논문AI추천

이 간행물의 다른 논문 (39건)