초록

This work is dedicated to the absorbed dose parameters around the INTRABEAM electronic BrachyTherapy (eBT) system in two configurations of bare needle and 40 mm diameter spherical applicator. It is done utilizing a micro- Diamond (mD) waterproof detector based on AAPM Task Group No. 292 suggestion. For this purpose, the eBT device has been simulated leveraging FLUKA Monte Carlo (MC) code for gamma-electron therapy, and the dose parameters have been determined. The produced low-energy bremsstrahlung X-ray spectra in bare needle and spherical applicator scenarios have been obtained. This factor has been compared in air and 15 mm depth water. Furthermore, a comparison study has been demonstrated between 192Ir radionuclide brachytherapy and eBT source, which shows the efficacy of eBT in standard tissue-sparing mechanisms. Moreover, the absorbed dose rate used to calculate the absorbed dose for a specific activity has been documented. This study demonstrates the potential for accurate simulation-based assessment of X-ray dose parameters within this energy range using the FLUKA MC approach. This work bridges the gap between clinical observations and MC simulations while minimizing dose absorption uncertainties. This advancement provides valuable perspectives for prospective research pursuits.

Abstract

This work is dedicated to the absorbed dose parameters around the INTRABEAM electronic BrachyTherapy (eBT) system in two configurations of bare needle and 40 mm diameter spherical applicator. It is done utilizing a micro- Diamond (mD) waterproof detector based on AAPM Task Group No. 292 suggestion. For this purpose, the eBT device has been simulated leveraging FLUKA Monte Carlo (MC) code for gamma-electron therapy, and the dose parameters have been determined. The produced low-energy bremsstrahlung X-ray spectra in bare needle and spherical applicator scenarios have been obtained. This factor has been compared in air and 15 mm depth water. Furthermore, a comparison study has been demonstrated between 192Ir radionuclide brachytherapy and eBT source, which shows the efficacy of eBT in standard tissue-sparing mechanisms. Moreover, the absorbed dose rate used to calculate the absorbed dose for a specific activity has been documented. This study demonstrates the potential for accurate simulation-based assessment of X-ray dose parameters within this energy range using the FLUKA MC approach. This work bridges the gap between clinical observations and MC simulations while minimizing dose absorption uncertainties. This advancement provides valuable perspectives for prospective research pursuits.

관련 논문AI추천

Geant 4 Monte Carlo simulation for I-125 brachytherapyElsayed A.M.M., Liu Jie, Medhat M.E.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제7호Validation of electromagnetic physics models and electron range in Geant4 Brachytherapy applicationAbabneh E., Albqoor A., Okoor S., Zahran I.한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제1호Dosimetric and energy deposition evaluation of the dual-microcavity capsule structure for glioma 125I brachytherapy using Monte Carlo simulationGao Weida, Guan Zhongbao, Liang Yu, Li Dongjie, Yao Gang한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제7호Determination of dosimetric dependence for effective atomic number of LDR brachytherapy seed capsule by Monte Carlo simulationCamgöz Berkay, Tarım Dilara한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제8호RBE evaluation during the vertebral and brain cancer treatment using low-kV X-rays: A hybrid simulation approachAlvarmir Zeynab, Baghani Hamid Reza, Shamsabadi Reza한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제8호Distance and Angular Dependence of Polycrystalline Semiconductor Dosimeters Based on Mercury(II) Iodide (HgI2) and Tallium(I) Bromide(TlBr) for an Iridium-192 Source: Experimental Measurements and Monte Carlo Simulation Comparison강상원, 김연래, 정진범, 한무재대한방사선과학회 · Journal of Radiological Science and Technology2025 · 제48권 제6호

이 간행물의 다른 논문 (59건)