Robust dosimetric evaluation of FLASH proton beams using plane-parallel ionization chambers and EBT-XD films for pre-clinical studies

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

This study established a robust methodology to evaluate the beam quality and dosimetric characteristics of FLASH-Proton beams. Dose plans were formulated for delivery of 3, 6, and 9 Gy at rates of 40 Gy/s and 70 Gy/s. The dosimetric evaluation employed two plane-parallel ionization chambers (ICs)—PPC-05 and Advanced Markus chamber—alongside EBT-XD film. Key parameters such as recombination and polarity effects of the ICs were measured, and the determined dose was quantified at predefined depths. Beam characteristics were further investigated using the EBT-XD film to corroborate IC findings. Polarity correction factors calculated for PPC-05 were 0.997 and 0.996 at 40 Gy/s and 70 Gy/s, respectively, with corresponding values for the Advanced Markus chamber of 1.0 and 0.999. The mean dose rates, derived from log files, were 52.3 Gy/s and 72.8 Gy/s for nominal rates of 40 Gy/s and 70 Gy/s, respectively. Depth dose profiles from the EBT-XD were analyzed at seven points and compared with measurements from PPC-05, revealing relative dose differences within ±5 % upon application of linear energy transfer correction. The established methodology is validated for routine clinical quality assurance.

Abstract

This study established a robust methodology to evaluate the beam quality and dosimetric characteristics of FLASH-Proton beams. Dose plans were formulated for delivery of 3, 6, and 9 Gy at rates of 40 Gy/s and 70 Gy/s. The dosimetric evaluation employed two plane-parallel ionization chambers (ICs)—PPC-05 and Advanced Markus chamber—alongside EBT-XD film. Key parameters such as recombination and polarity effects of the ICs were measured, and the determined dose was quantified at predefined depths. Beam characteristics were further investigated using the EBT-XD film to corroborate IC findings. Polarity correction factors calculated for PPC-05 were 0.997 and 0.996 at 40 Gy/s and 70 Gy/s, respectively, with corresponding values for the Advanced Markus chamber of 1.0 and 0.999. The mean dose rates, derived from log files, were 52.3 Gy/s and 72.8 Gy/s for nominal rates of 40 Gy/s and 70 Gy/s, respectively. Depth dose profiles from the EBT-XD were analyzed at seven points and compared with measurements from PPC-05, revealing relative dose differences within ±5 % upon application of linear energy transfer correction. The established methodology is validated for routine clinical quality assurance.

관련 논문AI추천

Characterization of real-time dose measurement using monitor ionization chamber in electron beam FLASH radiotherapyHu Zhenguo, Lang Xinle, Li Juan, Li Min, Luo Faming, Mao Ruishi, Xiao Guoqing, Xu Zhiguo, Zhou Kai한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제6호Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons김현, 강상구, 이만우, 이상진, 장경원, 정동혁, Lim Heuijin한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제9호Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제6호Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system구영모, 김성훈, 김찬형, 장세현, 정종휘, 조성구, 조재호, 최세훈한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제9호Performance Evaluation of Stealth Chamber as a Novel Reference Chamber for Measuring Percentage Depth Dose and Profile of VitalBeam Linear Accelerator강상원, 강성희, 김경현, 김연래, 서태석, 신영주, 이정우, 정재용, 정진범대한방사선과학회 · Journal of Radiological Science and Technology2018 · 제41권 제3호Upgrade of gamma electron vertex imaging system for high-performance range verifi cation in pencil beam scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘, 조광현, 조성구한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제3호

이 간행물의 다른 논문 (59건)