본문 바로가기
KERD
논문KCI 등재

A comparison of dimensional standard of several nickel-titanium rotary files

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: The aim of this study was to compare the dimensional standard of severalnickel-titanium (Ni-Ti) rotary files and verify the size conformity. Materials andMethods: ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo)#25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a totalof 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16,Olympus) at 32×. Taper and diameter at D1 to D16 of each files were calculated digitallywith AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper,the diameter of each level (D1 to D16) at 1 mm interval from (ANSI/ADA) specificationNo. 101 were statistically analyzed using one-way ANOVA and Scheffe’s post–hoc testat 95% confidence level. Results: TF was the only group not conform to the nominaltaper in both tapers (p < 0.05). All groups except 0.06 taper ProFile showed significantdifference from the nominal diameter (p < 0.05). Conclusions: Actual size of Ni-Ti file,especially TF, was different from the manufacturer’s statements.

Abstract

Objectives: The aim of this study was to compare the dimensional standard of severalnickel-titanium (Ni-Ti) rotary files and verify the size conformity. Materials andMethods: ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo)#25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a totalof 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16,Olympus) at 32×. Taper and diameter at D1 to D16 of each files were calculated digitallywith AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper,the diameter of each level (D1 to D16) at 1 mm interval from (ANSI/ADA) specificationNo. 101 were statistically analyzed using one-way ANOVA and Scheffe’s post–hoc testat 95% confidence level. Results: TF was the only group not conform to the nominaltaper in both tapers (p < 0.05). All groups except 0.06 taper ProFile showed significantdifference from the nominal diameter (p < 0.05). Conclusions: Actual size of Ni-Ti file,especially TF, was different from the manufacturer’s statements.

참고문헌 (30)

  1. 윤민정, "Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교", Restorative Dentistry and Endodontics, 36(1), pp.59~65 (2011), 대한치과보존학회
  2. Ruddle CJ., "Nickel-titanium rotary instruments: current concepts for preparing the root canal system", Aust Endod J, 29, pp.87~98 (2003)
  3. "The need for endodontic instrument standardization", Oral Surg Oral Med Oral Pathol, 8, pp.1211~1213 (1955)
  4. Grossman LI., "Transactions of the second international conference on endodontics" (1958), University of Pennsylvania Press
  5. Ingle JI, "The need for uniformity of endodontic instruments", equipment and filling materials, 234, pp.123~142
  6. Stenman E, "Spångberg LS. Root canal instruments are poorly standardized", J Endod, 19, pp.327~334 (1993)
  7. Ingle JI., "A standardized endodontic technique utilizing newly designed instruments and filling materials", Oral Surg Oral Med Oral Pathol, 14, pp.83~91 (1961)
  8. Heuer M., "The biomechanics of endodontic therapy", Dent Clin North Am, 13, pp.341~359 (1963)
  9. American Dental Association Council on Dental Materials, "Instruments, and Equipment. Revised ANSI", ADA specification no. 28: root canal files and reamers, type K, 1981
  10. American Dental Association Council on Scientific Affairs, "ANSI", ADA specification no. 28: root canal files and reamers, type K, 2008
  11. International Organization for Standardization, "ISO-Standards ISO 3630 Dentistry-Root canal instruments -Part 1: General requirements and test methods", pp.1~18 (2008)
  12. American Dental Association Council on Scientific Affairs, "ANSI", ADA specification no. 101: root canal instruments-general requirements, 2001
  13. Zinelis S, "Clinical relevance of standardization of endodontic files dimensions according to the ISO 3630-1 specification", J Endod, 28, pp.367~370 (2002)
  14. Keate KC, "Comparison of endodontic file tip quality", J Endod, 16, pp.486~491 (1990)
  15. Cormier CJ, "Chamberlain JH. A comparison of endodontic file quality and file dimensions", J Endod, 14, pp.138~142 (1988)
  16. Dearing GJ, "An objective evaluation comparing the physical properties of two brands of stainless steel endodontic hand files", J Endod, 31, pp.827~830 (2005)
  17. Schäfer E, "Bending properties of rotary nickel-titanium instruments", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 96, pp.757~763 (2003)
  18. Lask JT, "Variability of the diameter and taper of size #30, 0.04nickel-titanium rotary files", J Endod, 32, pp.1171~1173 (2006)
  19. Hatch GW, "Comparative study of the variability of 0.06 tapered rotary endodontic files to current taper standards", J Endod, 34, pp.463~465 (2008)
  20. Gambarini G, "Fatigue resistance of enginedriven rotary nickel-titanium instruments produced by new manufacturing methods", J Endod, 34, pp.1003~1005 (2008)
  21. El Batouty KM, "Comparison of canal transportation and changes in canal curvature of two nickel-titanium rotary instruments", J Endod, 37, pp.1290~1292 (2011)
  22. Gambarini G, "Mechanical properties of a new and improved nickeltitanium alloy for endodontic use: an evaluation of file flexibility", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 105, pp.798~800 (2008)
  23. Oh SR, "A comparison of nickel-titanium rotary instruments manufactured using different methods and cross-sectional areas: ability to resist cyclic fatigue", ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 109(4), pp.622~628 (2010), MOSBY-ELSEVIER
  24. Kim HC, "Cyclic fatigue and fracture characteristics of ground and twisted nickeltitanium rotary files", J Endod, 36, pp.147~152 (2010)
  25. Hou X, "Phase transformation behaviour and bending property of twisted nickel-titanium endodontic instruments", Int Endod J, 44, pp.253~258 (2011)
  26. Camps JJ, "Relationship between file size and stiffness of stainless steel instruments", Endod Dent Traumatol, 10, pp.260~263 (1994)
  27. Camps JJ, "Relationship between file size and stiffness of nickel-titanium instruments", Endod Dent Traumatol, 11, pp.270~273 (1995)
  28. Schäfer E, "Relationship between design features of endodontic instruments and their properties. Part 3. Resistance to bending and fracture", J Endod, 27, pp.299~303 (2001)
  29. Turpin YL, "Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal instrument models", J Endod, 26, pp.414~417 (2000)
  30. 김보혜, "엔진구동형 NiTi 파일의 근관성형능력 비교", Restorative Dentistry and Endodontics, 35(2), pp.88~95 (2010), 대한치과보존학회

관련 논문AI추천

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS이윤, 금기연, 오소람, 임상민, 황수연대한치과보존학회 · Restorative Dentistry and Endodontics2009 · 제34권 제5호Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatmentKoray Yılmaz and Gülşah Uslu, Taha Özyürek대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제1호Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvatureWafaa A. Khalil, Zuhair S. Natto대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제2호Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro studyHadeer Mostafa El Feky, Khalid Mohammed Ezzat, Marwa Mahmoud Ali Bedier대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제4호Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systemsAnand Sherwood Inbaraj, Ernest Prince Prakasam, Ramyadharshini Tamilkumaran, Vaanjay Murugadoss, Vigneshwar V Shanmugham대한치과보존학회 · Restorative Dentistry and Endodontics2020 · 제45권 제2호Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic filesArbab-Chirani Reza, Arbab-Chirani Shabnam, Chevalier Valérie, Gouédard Charlotte, Pino Laurent대한치과보존학회 · Restorative Dentistry and Endodontics2022 · 제47권 제2호

이 간행물의 다른 논문 (13건)