본문 바로가기
KERD
논문KCI 등재

Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.

Abstract

Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.

참고문헌 (29)

  1. Park SK, "Clinical efficiency and reusability of the reciprocating nickel-titanium instruments according to the root canal anatomy", Scanning, 36, pp.246~251 (2014)
  2. Peters OA, "Current challenges and concepts in the preparation of root canal systems : a review", J Endod, 30, pp.559~567 (2004)
  3. Schäfer E, "Cutting efficiency of five different types of rotary nickel-titanium instruments", J Endod, 34, pp.198~200 (2008)
  4. Bui TB, "Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency", J Endod, 34, pp.190~193 (2008)
  5. Fayyad DM, "Cutting efficiency of twisted versus machined nickel-titanium endodontic files", J Endod, 37, pp.1143~1146 (2011)
  6. Berutti E, "Use of nickel-titanium rotary PathFile to create the glide path : comparison with manual preflaring in simulated root canals", J Endod, 35, pp.408~412 (2009)
  7. Blum JY, "Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments", Int Endod J, 32, pp.24~31 (1999)
  8. Peters OA, "ProTaper rotary root canal preparation : assessment of torque and force in relation to canal anatomy", Int Endod J, 36, pp.93~99 (2003)
  9. Yared GM, "Influence of rotational speed, torque and operator's proficiency on ProFile failures", Int Endod J, 34, pp.47~53 (2001)
  10. Berutti E, "Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments", J Endod, 30, pp.228~230 (2004)
  11. Patiño PV, "The influence of a manual glide path on the separation rate of NiTi rotary instruments", J Endod, 31, pp.114~116 (2005)
  12. Yared G, "Canal preparation using only one Ni-Ti rotary instrument : preliminary observations", Int Endod J, 41, pp.339~344 (2008)
  13. Çapar ID, "A review of instrumentation kinematics of engine-driven nickel-titanium instruments", Int Endod J, 49, pp.119~135 (2016)
  14. Schneider SW, "A comparison of canal preparations in straight and curved root canals", Oral Surg Oral Med Oral Pathol, 32, pp.271~275 (1971)
  15. Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
  16. Plotino G, "Current assessment of reciprocation in endodontic preparation : a comprehensive review--part II : properties and effectiveness", J Endod, 41, pp.1939~1950 (2015)
  17. Hwang YH, "Shaping ability of the conventional nickel-titanium and reciprocating nickel-titanium file systems : a comparative study using micro-computed tomography", J Endod, 40, pp.1186~1189 (2014)
  18. Gu LS, "Review of contemporary irrigant agitation techniques and devices", J Endod, 35, pp.791~804 (2009)
  19. Jin SY, "Single file reciprocating technique using conventional nickel-titanium rotary endodontic files", Scanning, 35, pp.349~354 (2013)
  20. Kim HC, "Micro-computed tomography and scanning electron microscopy comparisons of two nickel-titanium rotary root canal instruments used with reciprocating motion", Scanning, 35, pp.112~118 (2013)
  21. Franco V, "Investigation on the shaping ability of nickel-titanium files when used with a reciprocating motion", J Endod, 37, pp.1398~1401 (2011)
  22. Marks Duarte P, "Canal transportation, centering ability, and cyclic fatigue promoted by Twisted File Adaptive and Navigator EVO instruments at different motions", J Endod, 44, pp.1425~1429 (2018)
  23. Al-Obaida MI, "Comparison of cyclic fatigue resistance of 5 heat-treated nickel-titanium reciprocating systems in canals with single and double curvatures", J Endod, 45, pp.1237~1241 (2019)
  24. Higuera O, "Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals", J Endod, 41, pp.913~915 (2015)
  25. Zupanc J, "New thermomechanically treated NiTi alloys-a review", Int Endod J, 51, pp.1088~1103 (2018)
  26. Meena D, "Influences of continuous rotation and TF adaptive motion on the resistance of different retreatment file systems to deformation and fracture : an in vitro study", J Oper Dent Endod, 3, pp.71~78 (2018)
  27. Kim HC, "Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals", Int Endod J, 42, pp.593~602 (2009)
  28. Gündoğar M, "Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue nickel-titanium instruments", J Endod, 43, pp.1192~1196 (2017)
  29. 하정홍, "Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals", Restorative Dentistry and Endodontics, 37(4), pp.215~219 (2012), 대한치과보존학회[DOI]

관련 논문AI추천

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals박상신, 하정홍대한치과보존학회 · Restorative Dentistry and Endodontics2012 · 제37권 제4호Effect of repetitive pecking at working length for glide path preparation using G-file김성교, 김현철, 장석우, 전효진, 하정홍, Rashid El Abed대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제2호Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium filesGülşah Uslu, Uğur İnan대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제2호In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canalsGülşah Uslu, Koray Yılmaz, Taha Özyürek대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제4호Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canalBueno Carlos Eduardo da Silveira, Calefi Pedro Henrique Souza, Dias Pedro de Souza, Duarte Marco Antonio Hungaro, Kato Augusto Shoji, Pelegrine Rina Andréa, Vivan Rodrigo Ricci대한치과보존학회 · Restorative Dentistry and Endodontics2023 · 제48권 제1호Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation곽상원, 김성교, 김현철, 이우철, 하정홍대한치과보존학회 · Restorative Dentistry and Endodontics2014 · 제39권 제4호

이 간행물의 다른 논문 (13건)