초록
Objectives The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial double-curvature canals. Materials and Methods This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test. Results The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05). Conclusions In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.
Abstract
Objectives The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial double-curvature canals. Materials and Methods This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test. Results The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05). Conclusions In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.
참고문헌 (22)
- Schilder H, "Cleaning and shaping the root canal", Dent Clin North Am, 18, pp.269~296 (1974)
- Tsesis I, "Prevalence and associated periodontal status of teeth with root perforation : a retrospective study of 2, 002 patients' medical records", J Endod, 36, pp.797~800 (2010)
- Aydin B, "Effectiveness of HERO 642 versus Hedström files for removing gutta-percha fillings in curved root canals : an ex vivo study", Int Endod J, 42, pp.1050~1056 (2009)
- Cujé J, "The outcome of retained instrument removal in a specialist practice", Int Endod J, 43, pp.545~554 (2010)
- Wilcox LR, "The relationship of root canal enlargement to finger-spreader induced vertical root fracture", J Endod, 23, pp.533~534 (1997)
- (2014)[URL]
- Higuera O, "Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals", J Endod, 41, pp.913~915 (2015)
- Al-Sudani D, "Cyclic fatigue of nickel-titanium rotary instruments in a double(S-shaped)simulated curvature", J Endod, 38, pp.987~989 (2012)
- Johnson E, "Comparison between a novel nickel-titanium alloy and 508 nitinol on the cyclic fatigue life of ProFile 25", .04 rotary instruments, 2008, pp.34, 1406~1409
- Yared G, "Canal preparation using only one Ni-Ti rotary instrument : preliminary observations", Int Endod J, 41, pp.339~344 (2008)
- Varela-Patiño P, "Alternating versus continuous rotation : a comparative study of the effect on instrument life", J Endod, 36, pp.157~159 (2010)
- Uslu G, "Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double(S-shaped)curvature", Int Endod J, 51, pp.584~589 (2018)
- Topçuoğlu HS, "Cyclic fatigue resistance of new reciprocating glide path files in 45-and 60-degree curved canals", Int Endod J, 51, pp.1053~1058 (2018)
- Serefoglu B, "Cyclic fatigue resistance of novel glide path instruments with different alloy properties and kinematics", J Endod, 44, pp.1422~1424 (2018)
- Keskin C, "Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments", Clin Oral Investig, 22, pp.3007~3012 (2018)
- Koray Yılmaz, "In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals", Restorative Dentistry and Endodontics, 42(4), pp.282~289 (2017), 대한치과보존학회
- Uslu G, "Comparison of cyclic fatigue resistance of ProGlider and One G glide path files", J Endod, 42, pp.1555~1558 (2016)
- Al-Hadlaq SM, "Evaluation of cyclic flexural fatigue resistance of 25", 0.04 and 25, Aust Endod J, pp.2013, 39[DOI]
- Larsen CM, "Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments", J Endod, 35, pp.401~403 (2009)
- Neelakantan P, "Cyclic fatigue of two different single files with varying kinematics in a simulated double-curved canal", J Investig Clin Dent, 7, pp.272~277 (2016)
- Duke F, "Cyclic fatigue of profile vortex and vortex blue nickel-titanium files in single and double curvatures", J Endod, 41, pp.1686~1690 (2015)
- Topçuoğlu HS, "Laboratory comparison of cyclic fatigue resistance ofWaveOne Gold, Reciproc and WaveOne files in canals with a double curvature", Int Endod J, 50, pp.713~717 (2017)