Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canal
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG). Materials and Methods: A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure. Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%. Results: The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue. Conclusions: Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments’ clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.
Abstract
Objectives: This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG). Materials and Methods: A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure. Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%. Results: The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue. Conclusions: Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments’ clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.
참고문헌 (29)
- Topçuoğlu HS, "Cyclic fatigue resistance of new reciprocating glide path files in 45-and 60-degree curved canals", Int Endod J, 51, pp.1053~1058 (2018)
- Yılmaz K, "Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature", Int Endod J, 51, pp.924~930 (2018)
- Elnaghy AM, "Evaluation of the mechanical behaviour of PathFile and ProGlider pathfinding nickel-titanium rotary instruments", Int Endod J, 48, pp.894~901 (2015)
- Uslu G, "Comparison of cyclic datigue resistance of ProGlider and One G Glide path files", J Endod, 42, pp.1555~1558 (2016)
- Keskin C, "Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments", Clin Oral Investig, 22, pp.3007~3012 (2018)
- Serefoglu B, "Cyclic fatigue resistance of novel glide path instruments with different alloy properties and kinematics", J Endod, 44, pp.1422~1424 (2018)
- Damla Kırıcı, "Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals", Restorative Dentistry and Endodontics, 44(4), pp.1~6 (2019), 대한치과보존학회
- Peters OA, "mechanical properties of a novel nickel-titanium root canal instrument : stationary and dynamic tests", J Endod, 46, pp.994~1001 (2020)
- Alcalde MP, "Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments", Clin Oral Investig, 22, pp.1865~1871 (2018)
- Santos CB, "Torsional fatigue resistance of R-Pilot and WaveOne Gold Glider NiTi glide path reciprocating systems", Int Endod J, 52, pp.874~879 (2019)
- da Frota MF, "Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems", J Oral Sci, 56, pp.269~275 (2014)
- Alcalde MP, "Cyclic and torsional fatigue resistance of reciprocating single files manufactured by different nickel-titanium alloys", J Endod, 43, pp.1186~1191 (2017)
- Pruett JP, "Cyclic fatigue testing of nickel-titanium endodontic instruments", J Endod, 23, pp.77~85 (1997)
- Lopes HP, "Mechanical behavior of pathfinding endodontic instruments", J Endod, 38, pp.1417~1421 (2012)
- Lee JY, "Mechanical properties of various Glide Path preparation nickel-titanium rotary instruments", J Endod, 45, pp.199~204 (2019)
- Elnaghy AM, "In vitro comparison of cyclic fatigue resistance of TruNatomy in single and double curvature canals compared with different nickel-titanium rotary instruments", BMC Oral Health, 20, pp.38~ (2020)
- Ajuz NC, "Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments", J Endod, 39, pp.534~537 (2013)
- Arias A, "Differences in torsional performance of single-and multiple-instrument rotary systems for glide path preparation", Odontology, 104, pp.192~198 (2016)
- De-Deus G, "Scouting ability of 4 pathfinding instruments in moderately curved molar canals", J Endod, 42, pp.1540~1544 (2016)
- Koray Yılmaz, "In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals", Restorative Dentistry and Endodontics, 42(4), pp.282~289 (2017), 대한치과보존학회
- Yared G, "Canal preparation using only one Ni-Ti rotary instrument : preliminary observations", Int Endod J, 41, pp.339~344 (2008)
- De-Deus G, "Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement", Int Endod J, 43, pp.1063~1068 (2010)
- Zupanc J, "New thermomechanically treated NiTi alloys-a review", Int Endod J, 51, pp.1088~1103 (2018)
- Weissheimer T, "Evaluation of the mechanical properties of different nickel-titanium retreatment instruments", Aust Endod J, 47, pp.265~272 (2021)
- Pedullà E, "Cutting efficiency of conventional and heat-treated nickel-titanium rotary or reciprocating glide path instruments", Int Endod J, 53, pp.376~384 (2020)
- Pereira RP, "A laboratory study of the scouting ability of two reciprocating glide path instruments in mesial root canals of extracted mandibular molars", Int Endod J, 54, pp.1166~1174 (2021)
- Lopes WS, "Bending, buckling and torsional resistance of rotary and reciprocating glide path instruments", Int Endod J, 53, pp.1689~1695 (2020)
- Vivan RR, "Torsional fatigue strength of reciprocating and rotary pathfinding instruments manufactured from different NiTi alloys", Braz Oral Res, 33, pp.e097~ (2019)
- Capar ID, "Comparison of the cyclic fatigue resistance of 5 different rotary pathfinding instruments made of conventional nickel-titanium wire, M-wire, and controlled memory wire", J Endod, 41, pp.535~538 (2015)
