Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature. Materials and Methods: Reciproc R25, WaveOne GOLD Primary, and Tango- Endo instruments were included in this study (n = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, 60°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and post-hoc Dunn tests were used for the statistical analysis of data in SPSS 21.0 software. Results: Tango- Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life (p < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files (p > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files (p < 0.05). Conclusions: Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.
Abstract
Objectives: To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature. Materials and Methods: Reciproc R25, WaveOne GOLD Primary, and Tango- Endo instruments were included in this study (n = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, 60°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and post-hoc Dunn tests were used for the statistical analysis of data in SPSS 21.0 software. Results: Tango- Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life (p < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files (p > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files (p < 0.05). Conclusions: Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.
참고문헌 (29)
- Walia HM, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
- Ankrum MT, "K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved roots of molars", J Endod, 30, pp.234~237 (2004)
- Peters OA, "Current challenges and concepts in the preparation of root canal systems: a review", J Endod, 30, pp.559~567 (2004)
- Gergi R, "Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography", J Endod, 36, pp.904~907 (2010)
- Gambarini G, "Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low-and high-torque endodontic motors", J Endod, 27, pp.772~774 (2001)
- Parashos P, "Rotary NiTi instrument fracture and its consequences", J Endod, 32, pp.1031~1043 (2006)
- Wan J, "A comparison of cyclic fatigue resistance in reciprocating and rotary nickel‐titanium instruments", Aust Endod J, 37, pp.122~127 (2011)
- Lopes HP, "Effects of electropolishing surface treatment on the cyclic fatigue resistance of BioRace nickel-titanium rotary instruments", J Endod, 36, pp.1653~1657 (2010)
- Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
- Varela-Patiño P, "Alternating versus continuous rotation: a comparative study of the effect on instrument life", J Endod, 36, pp.157~159 (2010)
- You SY, "Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals", J Endod, 36, pp.1991~1994 (2010)
- De-Deus G, "Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement", Int Endod J, 43, pp.1063~1068 (2010)
- Kim HC, "Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne", J Endod, 38, pp.541~544 (2012)
- "Tango-Endo brochure"[URL]
- Arens FC, "Evaluation of single-use rotary nickel-titanium instruments", J Endod, 29, pp.664~666 (2003)
- Yared G, "Canal preparation using only one Ni‐Ti rotary instrument: preliminary observations", Int Endod J, 41, pp.339~344 (2008)
- Cheung GS, "A numerical method for predicting the bending fatigue life of NiTi and stainless steel root canal instruments", Int Endod J, 44, pp.357~361 (2011)
- Plotino G, "A review of cyclic fatigue testing of nickel-titanium rotary instruments", J Endod, 35, pp.1469~1476 (2009)
- Yao JH, "Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model", J Endod, 32, pp.55~57 (2006)
- Hülsmann M, "Comparison of root canal preparation using different automated devices and hand instrumentation", J Endod, 19, pp.141~145 (1993)
- Weine FS, "Effect of preparation with endodontic handpieces on original canal shape", J Endod, 2, pp.298~303 (1976)
- "WaveOne GOLD brochure"[URL]
- H. S. Topçuoğlu, "Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature", International Endodontic Journal, 50(7), pp.713~717 (2017), Wiley-Blackwell[DOI]
- Özyürek T, "Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium instruments", J Endod, 42, pp.1536~1539 (2016)
- Scelza P, "A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests", Braz Oral Res, 29, pp.1~7 (2015)
- De-Deus G, "Bending resistance and dynamic and static cyclic fatigue life of Reciproc and WaveOne large instruments", J Endod, 40, pp.575~579 (2014)
- Pedullà E, "Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments", J Endod, 39, pp.258~261 (2013)
- Arias A, "Differences in cyclic fatigue resistance at apical and coronal levels of Reciproc and WaveOne new files", J Endod, 38, pp.1244~1248 (2012)
- Plotino G, "Cyclic fatigue of Reciproc and WaveOne reciprocating instruments", Int Endod J, 45, pp.614~618 (2012)