Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.
Abstract
Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.
참고문헌 (29)
- Cheung GS, "A retrospective study of endodontic treatment outcome between nickel-titanium rotary and stainless steel hand filing techniques", J Endod, 35, pp.938~943 (2009)
- Sattapan B, "Defects in rotary nickel-titanium files after clinical use", J Endod, 26, pp.161~165 (2000)
- Ullmann CJ, "Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments", J Endod, 31, pp.183~186 (2005)
- Lopes HP, "Cyclic fatigue of ProTaper instruments", J Endod, 33, pp.55~57 (2007)
- Capar ID, "Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments", Aust Endod J, 41, pp.24~28 (2015)
- Yared G, "Canal preparation using only one Ni-Ti rotary instrument : preliminary observations", Int Endod J, 41, pp.339~344 (2008)
- Plotino G, "Cyclic fatigue of Reciproc and WaveOne reciprocating instruments", Int Endod J, 45, pp.614~618 (2012)
- Shen Y, "WaveOne rotary instruments after clinical use", J Endod, 42, pp.186~189 (2016)
- West JD, "The endodontic Glidepath: “Secret to rotary safety”", Dent Today, 29, pp.86~88 (2010)
- D'Amario M, "Evaluation of a new nickel-titanium system to create the glide path in root canal preparation of curved canals", J Endod, 39, pp.1581~1584 (2013)
- Gambarini G, "Influence of different angles of reciprocation on the cyclic fatigue of nickel-titanium endodontic instruments", J Endod, 38, pp.1408~1411 (2012)
- Uslu G, "Comparison of cyclic fatigue resistance of ProGlider and one G glide path files", J Endod, 42, pp.1555~1558 (2016)
- Pruett JP, "Cyclic fatigue testing of nickel-titanium endodontic instruments", J Endod, 23, pp.77~85 (1997)
- Lopes HP, "Cyclic fatigue resistance of ProTaper universal instruments when subjected to static and dynamic tests", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 110, pp.401~404 (2010)
- Yao JH, "Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model", J Endod, 32, pp.55~57 (2006)
- De-Deus G, "Bending resistance and dynamic and static cyclic fatigue life of Reciproc and WaveOne large instruments", J Endod, 40, pp.575~579 (2014)
- Blum JY, "Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments : value of the safety quotient", J Endod, 29, pp.567~575 (2003)
- 하정홍, "Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals", Restorative Dentistry and Endodontics, 37(4), pp.215~219 (2012), 대한치과보존학회[DOI]
- Berutti E, "Root canal anatomy preservation of WaveOne reciprocating files with or without glide path", J Endod, 38, pp.101~104 (2012)
- Elnaghy AM, "Evaluation of root canal transportation, centering ratio, and remaining dentin thickness associated with ProTaper Next instruments with and without glide path", J Endod, 40, pp.2053~2056 (2014)
- Berutti E, "Energy consumption of ProTaper Next X1 after glide path with PathFiles and ProGlider", J Endod, 40, pp.2015~2018 (2014)
- Alovisi M, "Micro-CT evaluation of several glide path techniques and ProTaper Next shaping outcomes in maxillary first molar curved canals", Int Endod J, 50, pp.387~397 (2017)
- Ruddle CJ, "Endodontic canal preparation : innovations in glide path management and shaping canals", Dent Today, 33, pp.118~123 (2014)
- Özyürek T, "Effect of glide path creating on cyclic fatigue resistance of Reciproc and Reciproc Blue nickel-titanium files : a laboratory study", J Endod, 44, pp.1033~1037 (2018)
- Türker SA, "The effect of glide path on the surface quality of new and used rotary and reciprocating single files : OneShape versus WaveOne", Scanning, 36, pp.608~613 (2014)
- Kuhn G, "Influence of structure on nickel-titanium endodontic instruments failure", J Endod, 27, pp.516~520 (2001)
- Cheung GS, "Effect of torsional loading of nickel-titanium instruments on cyclic fatigue resistance", J Endod, 39, pp.1593~1597 (2013)
- Cunha RS, "Assessment of the separation incidence of reciprocating WaveOne files : a prospective clinical study", J Endod, 40, pp.922~924 (2014)
- Karova E, "The influence of a glide path on the lifespan of WaveOne reciprocating files", Int J Dent Sci Res, 2, pp.59~62 (2014)
