PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denturewas used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

Abstract

PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denturewas used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

참고문헌 (30)

  1. Basker RM, "Prosthetic treatment of the edentulous patient", pp.130~219 (2011), Wiley-Blackwell
  2. Bidra AS, "Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives", J Prosthet Dent, 109, pp.361~366 (2013)
  3. Schweiger J, "Systematics and concepts for the digital production of complete dentures : risks and opportunities", Int J Comput Dent, 21, pp.41~56 (2018)
  4. Baba NZ, "CAD", CAM complete denture systems and physical properties : a review of the literature, 2021, pp.30, 113~124
  5. Baba NZ, "Current techniques in CAD", CAM denture fabrication, 2016, pp.64, 23~28
  6. Baba NZ, "Materials and processes for CAD", CAM complete denture fabrication, 2016, pp.3, 203~208
  7. Steinmassl PA, "Evaluation of currently available CAD", CAM denture systems, 2017, pp.30, 116~122
  8. Bonnet G, "A new digital denture procedure : a first practitioners appraisal", BMC Oral Health, 17, pp.155~ (2017)
  9. Maragliano-Muniz P, "Incorporating digital dentures into clinical practice : flexible workflows and improved clinical outcomes", J Prosthodont, 30, pp.125~132 (2021)
  10. Felton DA, "Predictable impression procedures for complete dentures", Dent Clin North Am, 40, pp.39~51 (1996)
  11. Rignon-Bret C, "On comparing two different tray-holding techniques for edentulous maxillary impressions", Int J Prosthodont, 29, pp.169~172 (2016)
  12. 정수아, "Comparison of different impression techniques for edentulous jaws using three-dimensional analysis", The Journal of Advanced of Prosthodontics, 11(3), pp.179~186 (2019), 대한치과보철학회[DOI]
  13. Ishinabe S, "Mucosal thickness of the denture foundation under occlusal force", J Japan Prosthodont Soc, 35, pp.111~124 (1991)
  14. Smith PB, "Economic and clinical impact of digitally produced dentures", J Prosthodont, 30, pp.108~112 (2021)
  15. Kattadiyil MT, "Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting", J Prosthet Dent, 114, pp.818~825 (2015)
  16. Srinivasan M, "CAD", CAM milled removable complete dentures : time and cost estimation study, 2019, pp.80, 75~79
  17. Bidra AS, "Prospective cohort pilot study of 2-visit CAD", CAM monolithic complete dentures and implant-retained overdentures : Clinical and patient-centered outcomes, 2016, pp.115, 578~586.e1
  18. Kattadiyil MT, "Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting", J Prosthet Dent, 114, pp.818~825 (2015)
  19. Lo Russo L, "Three-dimensional differences between intraoral scans and conventional impressions of edentulous jaws: A clinical study", J Prosthet Dent, 123, pp.264~268 (2020)
  20. Fang JH, "Digital immediate denture : A clinical report", J Prosthet Dent, 119, pp.698~701 (2018)
  21. Goodacre BJ, "Using intraoral scanning to capture complete denture impressions, tooth positions, and centric relation records", Int J Prosthodont, 31, pp.377~381 (2018)
  22. Unkovskiy A, "Intraoral scanning to fabricate complete dentures with functional borders : a proof-of-concept case report", BMC Oral Health, 19, pp.46~ (2019)
  23. Kanazawa M, "Digital impression and jaw relation record for the fabrication of CAD", CAM custom tray, 2018, pp.62, 509~513
  24. Dawood A, "3D printing in dentistry", Br Dent J, 219, pp.521~529 (2015)
  25. Chen H, "Application of FDM three-dimensional printing technology in the digital manufacture of custom edentulous mandible trays", Sci Rep, 6, pp.19207~ (2016)
  26. Kihara H, "Applications of three-dimensional printers in prosthetic dentistry", J Oral Sci, 63, pp.212~216 (2021)
  27. Wagner SA, "Digitally fabricated removable complete denture clinical workflows using additive manufacturing techniques", J Prosthodont, 30, pp.133~138 (2021)
  28. Jovanović M, "A potential application of materials based on a polymer and CAD", CAM composite resins in prosthetic dentistry, 2021, pp.65, 137~147
  29. Parvizi A, "Comparison of the dimensional accuracy of injection-molded denture base materials to that of conventional pressure-pack acrylic resin", J Prosthodont, 13, pp.83~89 (2004)
  30. Schweiger J, "3D printing in digital prosthetic dentistry : an overview of recent developments in additive manufacturing", J Clin Med, 10, pp.2010~ (2021)

관련 논문AI추천

Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitationBassam Hassan, Daniel Wismeijer, Marcus Greven대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰박주미, 송광엽, 이정진대한치과의사협회 · 대한치과의사협회지2019 · 제57권 제9호Analysis of the trueness and precision of complete denture bases manufactured using digital and analog technologiesAngela Montanari, Laura Anderlucci, Leonardo Ciocca, Lorenzo Breschi, Mattia Maltauro, Roberto Meneghello, Valerio Cimini대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제1호Comparison of different impression techniques for edentulous jaws using three-dimensional analysis박찬, 박상원, 양홍서, 윤귀덕, 임현필, 정수아, Zhai Ying대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제3호Comparison of the accuracy of removable partial denture frameworks fabricated using conventional and digital impressions: a clinical study강유정, 김지환, 선민지, 윤명아, 전정호대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제5호Subtractive versus additive indirect manufacturing techniques of digitally designed partial denturesAhmed Mamdouh Snosi, Fardos Nabil Rizk, Marwa Ezzat Sabet, Shaimaa Mohamed Lotfy, Yasmine Galaleldin Thabet대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제5호

이 간행물의 다른 논문 (5건)