Purpose. Removable partial dentures (RPDs) require metal frameworks for support, stability, and retention. Conventional impression methods are time-consuming and may introduce inaccuracies that affect framework fit. Intraoral scanning (IOS) offers a digital alternative that may improve accuracy and efficiency; however, few studies have quantitatively compared frameworks fabricated using IOS data with those fabricated using conventional methods. This study aimed to compare the accuracy of RPD frameworks fabricated using conventional and IOS-based methods. Materials and methods. This study included 15 arches from 13 patients requiring RPDs. Each arch received two metal frameworks, one fabricated using the conventional impression method (CON group) and the other using IOS (IOS group). Qualitative evaluations included visual inspection and pressing with a plugger, whereas quantitative evaluations were performed using three-dimensional superimposition and gap measurements at the rest-seat areas. Paired t-tests were used to compare the accuracy, and two-way analysis of variance was used to evaluate the interaction between the fabrication method and tooth position. Results. All frameworks met the qualitative evaluation criteria. In the quantitative evaluation, the IOS group exhibited a significantly smaller mean gap (201 ± 78 µm) than the CON group (239 ± 83 µm) (P = .015). Furthermore, the IOS group demonstrated significantly greater accuracy, particularly at the terminal abutments of distal-extension RPDs. Conclusion. Clinically acceptable RPD framework accuracy was achieved in both groups. However, accuracy was significantly better in the IOS group, especially at the terminal abutments of distal-extension RPDs.

Abstract

Purpose. Removable partial dentures (RPDs) require metal frameworks for support, stability, and retention. Conventional impression methods are time-consuming and may introduce inaccuracies that affect framework fit. Intraoral scanning (IOS) offers a digital alternative that may improve accuracy and efficiency; however, few studies have quantitatively compared frameworks fabricated using IOS data with those fabricated using conventional methods. This study aimed to compare the accuracy of RPD frameworks fabricated using conventional and IOS-based methods. Materials and methods. This study included 15 arches from 13 patients requiring RPDs. Each arch received two metal frameworks, one fabricated using the conventional impression method (CON group) and the other using IOS (IOS group). Qualitative evaluations included visual inspection and pressing with a plugger, whereas quantitative evaluations were performed using three-dimensional superimposition and gap measurements at the rest-seat areas. Paired t-tests were used to compare the accuracy, and two-way analysis of variance was used to evaluate the interaction between the fabrication method and tooth position. Results. All frameworks met the qualitative evaluation criteria. In the quantitative evaluation, the IOS group exhibited a significantly smaller mean gap (201 ± 78 µm) than the CON group (239 ± 83 µm) (P = .015). Furthermore, the IOS group demonstrated significantly greater accuracy, particularly at the terminal abutments of distal-extension RPDs. Conclusion. Clinically acceptable RPD framework accuracy was achieved in both groups. However, accuracy was significantly better in the IOS group, especially at the terminal abutments of distal-extension RPDs.

관련 논문AI추천

Subtractive versus additive indirect manufacturing techniques of digitally designed partial denturesAhmed Mamdouh Snosi, Fardos Nabil Rizk, Marwa Ezzat Sabet, Shaimaa Mohamed Lotfy, Yasmine Galaleldin Thabet대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제5호Evaluation of trueness and precision of removable partial denture metal frameworks manufactured with digital technology and different materialsAngela Montanari, Elena Pierantozzi, Laura Anderlucci, Leonardo Ciocca, Lorenzo Breschi, Mattia Maltauro, Roberto Meneghello대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제2호Accuracy assessment of intraoral scanning versus conventional impressions in edentulous patients with flabby ridges: a prospective clinical studyAhmed Yaseen Alqutaibi, Ahmed Yehia Abdel-Moneim, Dina Mohamed Elawady, Sherin Samir Matta대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제6호Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-freedigital impression techniquesAyşegül Güleryüz Gürbulak, Hasan Kocaağaoğlu, Haydar Albayrak, Sezgi Cinel Sahin대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제5호Trueness of 3D printed partial denture frameworks; build orientations and support structure density parametersLamis Ahmed Hussein, Mostafa Omran Hussein대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제3호Digital versus conventional surveying for partially edentulous arches: an evaluation of accuracy and time efficiencyAdriana da Fonte Porto Carreiro, Ana Larisse Carneiro Pereira, Anne Kaline Claudino Ribeiro, Laércio Almeida de Melo, Luana Maria Martins de Aquino, Míria Rafaelli Souza Curinga, Rodrigo Falcão Carvalho Porto de Freitas대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제3호

이 간행물의 다른 논문 (6건)