총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰
Application and consideration of digital technology for removable complete denture
2
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.
Abstract
Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.
참고문헌 (12)
- Cunha TR, "A randomised trial on simplified and conventional methods for complete denture fabrication : Masticatory performance and ability", J Dent, 41, pp.133~142 (2013)
- Maeda Y, "A CAD", CAM system for removable denture. Part I: Fabrication of complete dentures, 1994, pp.7, 17~21
- Yuzbasioglu E, "Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes", BMC Oral Health, 14, pp.10~ (2014)
- 윤형인, "보철 치료 시 디지털 및 전통적 인상채득에 대한 환자 만족도 비교 연구", 대한치과보철학회지, 54(4), pp.379~386 (2016), 대한치과보철학회[DOI]
- Lee JH, "Improved digital impressions of edentulous areas", J Prosthet Dent, 117, pp.448~449 (2017)
- Fang JH, "Digital intraoral scanning technique for edentulous jaws", J Prosthet Dent, 119, pp.733~735 (2018)
- Fang JH, "Development of complete dentures based on digital intraoral impressions?Case report", J Prosthodont Res, 62, pp.116~120 (2018)
- Hong SJ, "Combining Conventional Impressions and Intraoral Scans: A Technique for the Treatment of Complete Denture Patients with Flabby Tissue", J Prosthodont (2019)
- Russo Lo L, "Alignment of intraoral scans and registration of maxillo-mandibular relationships for the edentulous maxillary arch", J Prosthet Dent (2019)
- Baba NZ, "Current techniques in CAD", CAM denture fabrication, 2016, pp.64, 23~28
- AlHelal A, "Comparison of retention between maxillary milled and conventional denture bases : A clinical study", J Prosthet Dent, 117, pp.233~238 (2017)
- Steinmassl O, "CAD", CAM produces dentures with improved fit, 2018, pp.22, 2829~2835