Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to postcuring time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute postcuring interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P <.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.
Abstract
PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to postcuring time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute postcuring interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P <.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.
참고문헌 (40)
- Burns DR, "A review of selected dental literature on contemporary provisional fixed prosthodontic treatment : report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics", J Prosthet Dent, 90, pp.474~497 (2003)
- Cheng CW, "Randomized clinical trial of a conventional and a digital workflow for the fabrication of interim crowns: an evaluation of treatment efficiency, fit, and the effect of clinician experience", J Prosthet Dent, 125, pp.73~81 (2021)
- 류지은, "Marginal and internal fit of 3D printed provisional crowns according to build directions", The Journal of Advanced of Prosthodontics, 12(4), pp.225~232 (2020), 대한치과보철학회[DOI]
- Abdulmohsen B, "A study to investigate and compare the physicomechanical properties of experimental and commercial temporary crown and bridge materials", Dent Mater, 32, pp.200~210 (2016)
- Peng CC, "Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods", J Prosthet Dent, 123, pp.514~522 (2020)
- Yu BY, "Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing", J Prosthet Dent (2020)
- Tahayeri A, "3D printed versus conventionally cured provisional crown and bridge dental materials", Dent Mater, 34, pp.192~200 (2018)
- 이완선, "Evaluation of internal fit of interim crown fabricated with CAD", CAM milling and 3D printing system, 2017, pp.9(4), 265~270[DOI]
- Revilla-León M, "A review on chemical composition, mechanical properties, and manufacturing work flow of additively manufactured current polymers for interim dental restorations", J Esthet Restor Dent, 31, pp.51~57 (2019)
- You SG, "Effect of layer thickness setting on the adaptation of stereolithography apparatus-fabricated metal frameworks for removable partial dentures : an in vitro study", J Prosthet Dent (2020)
- You SG, "Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems : An in vitro study", J Prosthet Dent, 125, pp.479~485 (2021)
- Lin WS, "Fabrication of an interim complete removable dental prosthesis with an in-office digital light processing three-dimensional printer : a proof-of-concept technique", J Prosthet Dent, 120, pp.331~334 (2018)
- Hwang HJ, "Assessment of the trueness and tissue surface adaptation of CADCAM maxillary denture bases manufactured using digital light processing", J Prosthet Dent, 121, pp.110~117 (2019)
- Kim DY, "Reproducibility of different arrangement of resin copings by dental microstereolithography : evaluating the marginal discrepancy of resin copings", J Prosthet Dent, 117, pp.260~265 (2017)
- You SM, "Evaluation of the accuracy(trueness and precision)of a maxillary trial denture according to the layer thickness : an in vitro study", J Prosthet Dent, 125, pp.139~145 (2021)
- Alharbi N, "Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology", Int J Prosthodont, 29, pp.503~510 (2016)
- Osman RB, "Build angle: Does it influence the accuracy of 3d-printed dental restorations using digital light-processing technology?", Int J Prosthodont, 30, pp.182~188 (2017)
- Sherman SL, "Accuracy of digital light processing printing of 3-dimensional dental models", Am J Orthod Dentofacial Orthop, 157, pp.422~428 (2020)
- Revilla-León M, "Additive Manufacturing Technologies Used for Processing Polymers : current Status and Potential Application in Prosthetic Dentistry", J Prosthodont, 28, pp.146~158 (2019)
- Chockalingam K, "Influence of layer thickness on mechanical properties in stereolithography", Rapid Prototyp J, 12, pp.106~113 (2006)
- Unkovskiy A, "Objects build orientation, positioning, and curing influence dimensional accuracy and flexural properties of stereolithographically printed resin", Dent Mater, 34, pp.e324~e333 (2018)
- Stansbury JW, "3D printing with polymers : challenges among expanding options and opportunities", Dent Mater, 32, pp.54~64 (2016)
- 강신영, "Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique", The Journal of Advanced of Prosthodontics, 10(5), pp.354~360 (2018), 대한치과보철학회[DOI]
- Jockusch J, "Additive manufacturing of dental polymers: an overview on processes, materials and applications", Dent Mater J, 39, pp.345~354 (2020)
- "ISO-12836. Digitizing devices for CAD/CAM systems for indirect dental restorations - test methods for assessing accuracy" (2012)[URL]
- Kang SY, "Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design", manufacturing system : an in vitro study, 2020, pp.64, 152~158
- Wang W, "Trueness analysis of zirconia crowns fabricated with 3-dimensional printing", J Prosthet Dent, 121, pp.285~291 (2019)
- Michelinakis G, "A comparison of accuracy of 3 intraoral scanners : a single-blinded in vitro study", J Prosthet Dent, 124, pp.581~588 (2020)
- Katheng A, "Evaluation of dimensional accuracy and degree of polymerization of stereolithography photopolymer resin under different postpolymerization conditions : an in vitro study", J Prosthet Dent, 125, pp.695~702 (2021)
- Kalberer N, "CAD-CAM milled versus rapidly prototyped(3D-printed)complete dentures : an in vitro evaluation of trueness", J Prosthet Dent, 121, pp.637~643 (2019)
- Park GS, "Effects of printing parameters on the fit of implant-supported 3d printing resin prosthetics", Materials(Basel), 12, pp.2533~ (2019)
- Bass L, "Exploring variability of orientation and aging effects in material properties of multi-material jetting parts", Rapid Prototyp J, 22, pp.826~834 (2016)
- Khoshkhoo A, "Effect of build orientation and part thickness on dimensional distortion in material jetting processes", Rapid Prototyp J, 24, pp.1563~1571 (2018)
- Patzelt SB, "Accuracy of computer-aided design", computer-aided manufacturing-generated dental casts based on intraoral scanner data, 2014, pp.145, 1133~1140
- Ishida Y, "Dimensional accuracy of dental casting patterns created by 3D printers", Dent Mater J, 35, pp.250~256 (2016)
- Kirsch C, "Trueness of four different milling procedures used in dental CAD", CAM systems, 2017, pp.21, 551~558
- Berger U, "Aspects of accuracy and precision in the additive manufacturing of plastic gears", Virtual Phys Prototyp, 10, pp.49~57 (2015)
- Wu D, "Mechanics of shape distortion of DLP 3D printed structures during UV post-curing", Soft Matter, 15, pp.6151~6159 (2019)
- Ender A, "In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions", J Prosthet Dent, 115, pp.313~320 (2016)
- Chen H, "Comparison of flexural properties and cytotoxicity of interim materials printed from mono-LCD and DLP 3D printers", J Prosthet Dent (2020)