본문 바로가기
KERD
논문KCI 등재

Assessment of Internal Fitness on Resin Crown Fabricated by Digital Light Processing 3D Printer

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Background: Recently, three-dimensional (3D) printing has been hailed as a disruptive technology in dentistry. Among 3D printers, a digital light processing (DLP) 3D printer has certain advantages, such as high precision and relatively low cost. Therefore, the latest trend in resin crown manufacturing is the use of DLP 3D printers. However, studies on the internal fitness of such resin crowns are insufficient. The recently introduced 3D evaluation method makes it possible to visually evaluate the error of the desired area. The purpose of this study is to evaluate the internal fitness of resin crowns fabricated a by DLP 3D printer using the 3D evaluation method. Methods: The working model was chosen as the maxillary molar implant model. A total of 20 resin crowns were manufactured by dividing these into two groups. One group was manufactured by subtractive manufacturing system (PMMA), while the other group was manufactured by additive manufacturing system, which uses a DLP 3D printer. Resin crowns data were measured using a 3D evaluation program. Internal fitness was calculated by root mean square (RMS). The RMS was calculated using the Geomagic Verify software, and the mean and standard deviation (SD) were measured. For statistical analysis, IBM SPSS Statistics for Windows ver. 22.0 (IBM Corp., USA) was used. Then, independent t-test was performed between the two groups. Results: The mean±SD of the RMS were 41.51±1.51 and 43.09±2.32 for PMMA and DLP, respectively. There was no statistically significant difference between PMMA and DLP. Conclusion: Evaluation of internal fitness of the resin crown made using a DLP 3D printer and subtractive manufacturing system showed no statistically significant differences, and clinically acceptable results were obtained.

Abstract

Background: Recently, three-dimensional (3D) printing has been hailed as a disruptive technology in dentistry. Among 3D printers, a digital light processing (DLP) 3D printer has certain advantages, such as high precision and relatively low cost. Therefore, the latest trend in resin crown manufacturing is the use of DLP 3D printers. However, studies on the internal fitness of such resin crowns are insufficient. The recently introduced 3D evaluation method makes it possible to visually evaluate the error of the desired area. The purpose of this study is to evaluate the internal fitness of resin crowns fabricated a by DLP 3D printer using the 3D evaluation method. Methods: The working model was chosen as the maxillary molar implant model. A total of 20 resin crowns were manufactured by dividing these into two groups. One group was manufactured by subtractive manufacturing system (PMMA), while the other group was manufactured by additive manufacturing system, which uses a DLP 3D printer. Resin crowns data were measured using a 3D evaluation program. Internal fitness was calculated by root mean square (RMS). The RMS was calculated using the Geomagic Verify software, and the mean and standard deviation (SD) were measured. For statistical analysis, IBM SPSS Statistics for Windows ver. 22.0 (IBM Corp., USA) was used. Then, independent t-test was performed between the two groups. Results: The mean±SD of the RMS were 41.51±1.51 and 43.09±2.32 for PMMA and DLP, respectively. There was no statistically significant difference between PMMA and DLP. Conclusion: Evaluation of internal fitness of the resin crown made using a DLP 3D printer and subtractive manufacturing system showed no statistically significant differences, and clinically acceptable results were obtained.

참고문헌 (29)

  1. Tinschert J, "Status of current CAD", CAM technology in dental medicine, 2004, pp.7, 25~45
  2. Dianne Rekow, "Computer-aided design and manufacturing in dentistry: A review of the state of the art", The Journal of Prosthetic Dentistry, 58(4), pp.512~516 (1987), Elsevier BV[DOI]
  3. Nachum Samet, "A CAD", CAM system for the production of metal copings for porcelain-fused-to-metal restorations, 1995, pp.73(5), 457~463[DOI]
  4. F. Beuer, "Digital dentistry: an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204(9), 505~511[DOI]
  5. Dean Vafiadis, "Single visit fabrication of a porcelain laminate veneer with CAD", CAM technology: A clinical report, 2011, pp.106(2), 71~73[DOI]
  6. 송준기, "절삭 및 적층 가공 방법으로 제작된 작업 모형의 정확도 비교", 대한치과재료학회지, 45(1), pp.89~96 (2018), 대한치과재료학회[DOI]
  7. Andreas Ender, "Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision", The Journal of Prosthetic Dentistry, 109(2), pp.121~128 (2013), Elsevier BV[DOI]
  8. 최재우, "치과용 구강 스캐너와 모델 스캐너를 이용하여 제작된 보철물의 변연적합도", 대한치과재료학회지, 44(1), pp.79~86 (2017), 대한치과재료학회[DOI]
  9. Massimo Martorelli, "A comparison between customized clear and removable orthodontic appliances manufactured using RP and CNC techniques", Dental Materials, 29(2), pp.e1~e10 (2013), Elsevier BV[DOI]
  10. Richard van Noort, "The future of dental devices is digital", Dental Materials, 28(1), pp.3~12 (2012), Elsevier BV[DOI]
  11. Jürgen Stampfl, "New Materials for Rapid Prototyping Applications", Macromolecular Chemistry and Physics, 206(13), pp.1253~1256 (2005), Wiley[DOI]
  12. Aletta Hazeveld, "Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques", American Journal of Orthodontics and Dentofacial Orthopedics, 145(1), pp.108~115 (2014), Elsevier BV[DOI]
  13. Advanced DLP for superior 3D printing, "Envision TEC", Envision TEC, 1~8 (2017)
  14. 신동훈, "DLP 공정을 이용한 정밀 치아모델 제작에서 UV 조사량과 후경화 수축률의 상관관계 분석", 한국기계가공학회지, 17(2), pp.47~53 (2018), 한국기계가공학회[DOI]
  15. Soo-Yeon Kim, "Precision and trueness of dental models manufactured with different 3-dimensional printing techniques", American Journal of Orthodontics and Dentofacial Orthopedics, 153(1), pp.144~153 (2018), Elsevier BV[DOI]
  16. 문준모, "가속노화 효과에 의한 치과용 3D 프린터 출력물의 변형도 평가", 대한치과재료학회지, 44(1), pp.53~60 (2017), 대한치과재료학회[DOI]
  17. Yeon Jang, "Accuracy of 3-unit fixed dental prostheses fabricated on 3D-printed casts", The Journal of Prosthetic Dentistry, 123(1), pp.135~142 (2020), Elsevier BV[DOI]
  18. Dong-Yeon Kim, "Comparison and evaluation of marginal and internal gaps in cobalt–chromium alloy copings fabricated using subtractive and additive manufacturing", Journal of Prosthodontic Research, 62(1), pp.56~64 (2018), Elsevier BV[DOI]
  19. Jihye Jung, "Marginal and internal fit of metallic and zirconia copings depending on manufacturing methods.", Clinical Oral Implants Research, 29, pp.192~192 (2018), Wiley[DOI]
  20. 한만소, "주조에 의한 Core와 CAD-CAM에 의한 Core의 적합도 비교평가", 치위생과학회지, 12(4), pp.368~374 (2012), 한국치위생과학회
  21. Manuel Antonio Pimenta, "Evaluation of marginal and internal fit of ceramic and metallic crown copings using x-ray microtomography (micro-CT) technology", The Journal of Prosthetic Dentistry, 114(2), pp.223~228 (2015), Elsevier BV[DOI]
  22. 황수현, "커피종류에 따른 자가중합형 임시치관용 레진의 색 안정성에 관한 연구", 치위생과학회지, 12(4), pp.342~347 (2012), 한국치위생과학회
  23. 박지원, "자가중합 임시치관용 레진의 표면 처리에 따른 색 안정성", 치위생과학회지, 16(2), pp.150~156 (2016), 한국치위생과학회
  24. JAN-FREDERIK GÜTH, "Treatment Concept with CAD", CAM-Fabricated High-Density Polymer Temporary Restorations, 2012, pp.24(5), 310~318[DOI]
  25. Andreas Ender, "In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions", The Journal of Prosthetic Dentistry, 115(3), pp.313~320 (2016), Elsevier BV[DOI]
  26. Pablo González de Villaumbrosia, "In vitro comparison of the accuracy (trueness and precision) of six extraoral dental scanners with different scanning technologies", The Journal of Prosthetic Dentistry, 116(4), pp.543~550.e1 (2016), Elsevier BV[DOI]
  27. Frank S. Andriessen, "Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study", The Journal of Prosthetic Dentistry, 111(3), pp.186~194 (2014), Elsevier BV[DOI]
  28. Panos Papaspyridakos, "Digital versus conventional implant impressions for edentulous patients: accuracy outcomes", Clinical Oral Implants Research, 27(4), pp.465~472 (2016), Wiley[DOI]
  29. Knud Dreyer Jørgensen, "The Relationship Between the Film Thickness of Zinc Phosphate Cement and the Retention of Veneer Crowns", Acta Odontologica Scandinavica, 26(3), pp.169~176 (2009), Informa UK Limited[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (9건)