PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) μm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) μm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.
Abstract
PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) μm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) μm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.
참고문헌 (24)
- Balkenhol M, "Wöstmann B. Correlation between polymerization shrinkage and marginal fit of temporary crowns", Dent Mater, 24, pp.1575~1584 (2008)
- Ehrenberg D, "Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: a pilot study", J Prosthet Dent, 95, pp.230~236 (2006)
- Ehrenberg DS, "Changes in marginal gap size of provisional resin crowns after occlusal loading and thermal cycling", J Prosthet Dent, 84, pp.139~148 (2000)
- Oxman JD, "Dental crown liner composition and methods of preparing provisional applications", U.S. Patent No 5,709,548, ~ (1998)
- Abouelatta OB, "Surface integrity of provisional resin materials", Meas Sci Technol, 17, pp.584~591 (2006)
- Nejatidanesh F, "Marginal accuracy of interim restorations fabricated from four interim autopolymerizing resins", J Prosthet Dent, 95, pp.364~367 (2006)
- Michalakis K, "Comparison of temperature increase in the pulp chamber during the polymerization of materials used for the direct fabrication of provisional restorations", J Prosthet Dent, 96, pp.418~423 (2006)
- Heying JJ, "Flexural strength of interim fixed prosthesis materials after simulated function", MA, pp.2009
- Regish KM, "Techniques of fabrication of provisional restoration: An overview", Int J Dent, 2011, pp.134659~ (2011)
- Alharbi N, "Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations", J Prosthet Dent, 115, pp.760~767 (2016)
- Syed M, "Allergic reactions to dental materials-a systematic review", J Clin Diagn Res, 9, pp.ZE04~ZE09 (2015)
- Torabi K, "Rapid prototyping technologies and their applications in prosthodontics, a review of literature", J Dent (Shiraz), 16, pp.1~9 (2015)
- Frazier WE, "Metal additive manufacturing: A review", J Mater Eng Perform, 23, pp.1917~1928 (2014)
- Stopp S, "A new method for printer calibration and contour accuracy manufacturing with 3D-print technology", Rapid Prototyp J, 14, pp.167~172 (2008)
- Sun J, "The application of rapid prototyping in prosthodontics", J Prosthodont, 21, pp.641~644 (2012)
- Kelvin Khng KY, "In vitro evaluation of the marginal integrity of CAD", CAM interim crowns, 2016, pp.115, 617~623
- Pimenta MA, "Evaluation of marginal and internal fit of ceramic and metallic crown copings using x-ray microtomography (micro-CT) technology", J Prosthet Dent, 114, pp.223~228 (2015)
- Sorensen JA, "A standardized method for determination of crown margin fidelity", J Prosthet Dent, 64, pp.18~24 (1990)
- Grenade C, "Fit of single tooth zirconia copings: comparison between various manufacturing processes", J Prosthet Dent, 105, pp.249~255 (2011)
- Molin M, "The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study", Acta Odontol Scand, 51, pp.201~206 (1993)
- Ostlund LE, "Cavity design and mathematics: their effect on gaps at the margins of cast restorations", Oper Dent, 10, pp.122~137 (1985)
- McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
- Boening KW, "Clinical fit of Procera AllCeram crowns", J Prosthet Dent, 84, pp.419~424 (2000)
- Liu Q, "Rapid prototyping in dentistry:technology and application", Int J Adv Manuf Technol, 29, pp.317~335 (2006)