본문 바로가기
KERD
논문KCI 등재

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

2

조회

0

다운로드

13

인용

0

참고문헌

키워드

초록

PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) μm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) μm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

Abstract

PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) μm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) μm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

참고문헌 (24)

  1. Balkenhol M, "Wöstmann B. Correlation between polymerization shrinkage and marginal fit of temporary crowns", Dent Mater, 24, pp.1575~1584 (2008)
  2. Ehrenberg D, "Long-term effects of storage and thermal cycling on the marginal adaptation of provisional resin crowns: a pilot study", J Prosthet Dent, 95, pp.230~236 (2006)
  3. Ehrenberg DS, "Changes in marginal gap size of provisional resin crowns after occlusal loading and thermal cycling", J Prosthet Dent, 84, pp.139~148 (2000)
  4. Oxman JD, "Dental crown liner composition and methods of preparing provisional applications", U.S. Patent No 5,709,548, ~ (1998)
  5. Abouelatta OB, "Surface integrity of provisional resin materials", Meas Sci Technol, 17, pp.584~591 (2006)
  6. Nejatidanesh F, "Marginal accuracy of interim restorations fabricated from four interim autopolymerizing resins", J Prosthet Dent, 95, pp.364~367 (2006)
  7. Michalakis K, "Comparison of temperature increase in the pulp chamber during the polymerization of materials used for the direct fabrication of provisional restorations", J Prosthet Dent, 96, pp.418~423 (2006)
  8. Heying JJ, "Flexural strength of interim fixed prosthesis materials after simulated function", MA, pp.2009
  9. Regish KM, "Techniques of fabrication of provisional restoration: An overview", Int J Dent, 2011, pp.134659~ (2011)
  10. Alharbi N, "Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations", J Prosthet Dent, 115, pp.760~767 (2016)
  11. Syed M, "Allergic reactions to dental materials-a systematic review", J Clin Diagn Res, 9, pp.ZE04~ZE09 (2015)
  12. Torabi K, "Rapid prototyping technologies and their applications in prosthodontics, a review of literature", J Dent (Shiraz), 16, pp.1~9 (2015)
  13. Frazier WE, "Metal additive manufacturing: A review", J Mater Eng Perform, 23, pp.1917~1928 (2014)
  14. Stopp S, "A new method for printer calibration and contour accuracy manufacturing with 3D-print technology", Rapid Prototyp J, 14, pp.167~172 (2008)
  15. Sun J, "The application of rapid prototyping in prosthodontics", J Prosthodont, 21, pp.641~644 (2012)
  16. Kelvin Khng KY, "In vitro evaluation of the marginal integrity of CAD", CAM interim crowns, 2016, pp.115, 617~623
  17. Pimenta MA, "Evaluation of marginal and internal fit of ceramic and metallic crown copings using x-ray microtomography (micro-CT) technology", J Prosthet Dent, 114, pp.223~228 (2015)
  18. Sorensen JA, "A standardized method for determination of crown margin fidelity", J Prosthet Dent, 64, pp.18~24 (1990)
  19. Grenade C, "Fit of single tooth zirconia copings: comparison between various manufacturing processes", J Prosthet Dent, 105, pp.249~255 (2011)
  20. Molin M, "The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study", Acta Odontol Scand, 51, pp.201~206 (1993)
  21. Ostlund LE, "Cavity design and mathematics: their effect on gaps at the margins of cast restorations", Oper Dent, 10, pp.122~137 (1985)
  22. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
  23. Boening KW, "Clinical fit of Procera AllCeram crowns", J Prosthet Dent, 84, pp.419~424 (2000)
  24. Liu Q, "Rapid prototyping in dentistry:technology and application", Int J Adv Manuf Technol, 29, pp.317~335 (2006)

관련 논문AI추천

Evaluation of the marginal and internal fit of a single crown fabricated based on a threedimensional printed model장연, 김웅철, 김지환, 김혜영, 박종경, 심지영대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호Marginal and internal fit of 3D printed provisional crowns according to build directions공현준, 김유리, 류지은, 장훈상, 정지혜대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제4호Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study김동연, 김지환, 유승규, 유승민, 이범일대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Internal and marginal adaptation of 3D printed interim fixed partial dentures with different layer thicknessesAzam Sadat Mostafavi, Fateme Ghorbanpour Arani, Mahya Hasanzade, Negin Aminianpour대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제3호Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study강신영, 김지환, 유승규, 유승민, 이범일대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제1호Assessment of Internal Fitness on Resin Crown Fabricated by Digital Light Processing 3D Printer김원기, Min-Su Kim, Wol Kang한국치위생과학회 · 치위생과학회지2019 · 제19권 제4호

이 간행물의 다른 논문 (11건)