치과용 3D 프린터로 제작된 임시 수복용 레진의 정확도 평가
Evaluation of the accuracy of provisional restorative resins fabricated using dental 3D printers
2
조회
0
다운로드
10
인용
0
참고문헌
키워드
초록
Objectives: The purpose of this study is to assess the accuracy of provisional restorative resins fabricated using dental three-dimensional (3D) printers. Methods: Provisional restorative resins were fabricated using the first molar of the right mandibular. Three groups comprising a total of 24 samples of such resins were fabricated. The prepared abutment was scanned initially and then designed using a computer-aided design (CAD) software. The conventional subtractive manufacturing system was employed to fabricate the first group of resins, while the second and third groups were fabricated using a digital light processing (DLP) 3D printer and a stereolithography (SLA) 3D printer, respectively. The internal surfaces of the resins were scanned and 3D measurements of the resins were taken to confirm their accuracy. Results: The root-mean-square deviation (RMS±SD) of the accuracy of the resins fabricated using the conventional subtractive manufacturing system, DLP 3D printer, and SLA 3D printer were 68.83±2.22 ㎛, 74.63±6.23 ㎛, and 61.74±4.09 ㎛, respectively. A one-way analysis of variance (ANOVA) test showed significant differences between the three groups (p < 0.05). Conclusions: Provisional restorative resins fabricated using DLP and SLA 3D printers demonstrated clinically-acceptable results.
Abstract
Objectives: The purpose of this study is to assess the accuracy of provisional restorative resins fabricated using dental three-dimensional (3D) printers. Methods: Provisional restorative resins were fabricated using the first molar of the right mandibular. Three groups comprising a total of 24 samples of such resins were fabricated. The prepared abutment was scanned initially and then designed using a computer-aided design (CAD) software. The conventional subtractive manufacturing system was employed to fabricate the first group of resins, while the second and third groups were fabricated using a digital light processing (DLP) 3D printer and a stereolithography (SLA) 3D printer, respectively. The internal surfaces of the resins were scanned and 3D measurements of the resins were taken to confirm their accuracy. Results: The root-mean-square deviation (RMS±SD) of the accuracy of the resins fabricated using the conventional subtractive manufacturing system, DLP 3D printer, and SLA 3D printer were 68.83±2.22 ㎛, 74.63±6.23 ㎛, and 61.74±4.09 ㎛, respectively. A one-way analysis of variance (ANOVA) test showed significant differences between the three groups (p < 0.05). Conclusions: Provisional restorative resins fabricated using DLP and SLA 3D printers demonstrated clinically-acceptable results.
참고문헌 (30)
- Lee SH, "Esthetic considerations for porcelain fused to metal restorations", The J of KDA, 20(2), pp.127~130 (1982)
- J.W.V van Dijken, "Direct resin composite inlays", onlays: an 11 year follow-up, 2000, pp.28(5), 299~306[DOI]
- Donald W. Fisher, "Indirect Temporary Restorations", The Journal of the American Dental Association, 82(1), pp.160~163 (1971), Elsevier BV[DOI]
- Lee SH, "A comparative study on the transverse strength of the provisional restoration acrylic resin according to the method of reinforcement", J Dent Rehab App Sci, 11(2), pp.191~205 (1995)
- Suh SJ, "Various application of PMMA temporary crown processed with five-axis milling machine at clinical dentist's office", J Korean Acad Esthet Dent, 26(2), pp.68~83 (2017)[DOI]
- Jin-Young Park, "In vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods", The Journal of Prosthetic Dentistry, 116(4), pp.536~542 (2016), Elsevier BV[DOI]
- 박상모, "3D 프린팅으로 제작된 여러 종류의 레진브릿지의 굴곡강도에 대한 연구", 구강회복응용과학지, 33(4), pp.260~268 (2017), 대한턱관절교합학회[DOI]
- Dong-Yeon Kim, "Reproducibility of different arrangement of resin copings by dental microstereolithography: Evaluating the marginal discrepancy of resin copings", The Journal of Prosthetic Dentistry, 117(2), pp.260~265 (2017), Elsevier BV[DOI]
- 조원탁, "제작방법에 따른 임시 수복용 레진의 파절강도 및 굴곡강도에 관한 연구", 대한치과보철학회지, 57(3), pp.225~231 (2019), 대한치과보철학회[DOI]
- Song DB, "Evaluation of mechanical properties and cytotoxicity of 3D printing prosthetic polymers", Doctor, pp.2019
- 안종주, "제작방법에 따른 임시 수복용 레진의 마모저항성에 관한 연구", 대한치과보철학회지, 57(2), pp.110~117 (2019), 대한치과보철학회[DOI]
- 장연, "Evaluation of the marginal and internal fit of a single crown fabricated based on a threedimensional printed model", The Journal of Advanced of Prosthodontics, 10(5), pp.367~373 (2018), 대한치과보철학회[DOI]
- Irena Sailer, "A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses.", Clinical Oral Implants Research, 18(3), pp.86~96 (2007), Wiley[DOI]
- 김소민, "수종의 복합레진에 대한 미세경도와 변연적합도 비교", 대한치과기공학회지, 33(2), pp.147~158 (2011), 대한치과기공학회
- 이기홍, "CAD", CAM 3-unit bridges의 변연 적합도에 관한 연구, 2011, pp.49(02), 101~105[DOI]
- 김단비, "인상체 스캔 및 석고모형 스캔으로 얻어진 디지털 모형의 3차원 정확성 비교", 대한치과재료학회지, 45(1), pp.11~20 (2018), 대한치과재료학회[DOI]
- 주용훈, "알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석", 구강회복응용과학지, 31(4), pp.316~328 (2015), 대한턱관절교합학회[DOI]
- Oliver Schaefer, "Three-dimensional fit of lithium disilicate partial crowns in vitro", Journal of Dentistry, 41(3), pp.271~277 (2013), Elsevier BV[DOI]
- 김성훈, "IPS Empress 도재관의 파절강도: 하악 제1대구치에서 교합면 두께와 축면경사도에 따른 영향", 대한치과보철학회지, 41(1), pp.48~60 (2003), 대한치과보철학회
- Cohen J, "Statistical power analysis for the behavioral sciences", pp.407~414 (1988), Lawrence Erlbaum Associates
- Keun-Young Lee, "Accuracy of three-dimensional printing for manufacturing replica teeth", 대한치과교정학회지, 45(5), pp.217~225 (2015), 대한치과교정학회
- 김재홍, "치과 CAD", CAM 가공방식에 따른 임시보철물의 내면 적합도 : 3차원 중첩 분석, 2019, pp.41(2), 81~86[DOI]
- 이현호, "고정성 보철물의 적합도에 대한 실험적 평가방법", 구강회복응용과학지, 33(2), pp.63~70 (2017), 대한턱관절교합학회[DOI]
- Gordon J. Christensen, "Marginal fit of gold inlay castings", The Journal of Prosthetic Dentistry, 16(2), pp.297~305 (1966), Elsevier BV[DOI]
- J W McLean, "The estimation of cement film thickness by an in vivo technique", British Dental Journal, 131(3), pp.107~111 (1971), Springer Science and Business Media LLC[DOI]
- 정승진, "다양한 CAD", CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구, 2019, pp.57(3), 211~218[DOI]
- 김총명, "2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가", 대한치과기공학회지, 38(2), pp.57~62 (2016), 대한치과기공학회[DOI]
- 김동연, "Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD", CAM systems, 2017, pp.9(6), 463~469[DOI]
- Advanced DLP For Superior 3D Printing, "Envision TEC", Envision TEC, 1~8 (2017)
- 신동훈, "DLP 공정을 이용한 정밀 치아모델 제작에서 UV 조사량과 후경화 수축률의 상관관계 분석", 한국기계가공학회지, 17(2), pp.47~53 (2018), 한국기계가공학회[DOI]
