본문 바로가기
KERD
논문KCI 등재

Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P =.004, P =.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P =.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P =.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.

Abstract

PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P =.004, P =.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P =.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P =.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.

참고문헌 (45)

  1. Nejatidanesh F, "Marginal accuracy of interim restorations fabricated from four interim autopolymerizing resins", J Prosthet Dent, 95, pp.364~367 (2006)
  2. Mai HN, "Fit of interim crowns fabricated using photopolymer-jetting 3D printing", J Prosthet Dent, 118, pp.208~215 (2017)
  3. Peng CC, "Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods", J Prosthet Dent, 123, pp.514~522 (2020)
  4. Balkenhol M, "Correlation between polymerization shrinkage and marginal fit of temporary crowns", Dent Mater, 24, pp.1575~1584 (2008)
  5. 강신영, "Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique", The Journal of Advanced of Prosthodontics, 10(5), pp.354~360 (2018), 대한치과보철학회[DOI]
  6. Yao J, "Comparison of the flexural strength and marginal accuracy of traditional and CAD", CAM interim materials before and after thermal cycling, 2014, pp.112, 649~657
  7. Park JY, "In vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods", J Prosthet Dent, 116, pp.536~542 (2016)
  8. Ng J, "A comparison of the marginal fit of crowns fabricated with digital and conventional methods", J Prosthet Dent, 112, pp.555~560 (2014)
  9. Revilla-León M, "Additive manufacturing technologies used for processing polymers : current status and potential application in prosthetic dentistry", J Prosthodont, 28, pp.146~158 (2019)
  10. Alghazzawi TF, "Advancements in CAD", CAM technology : options for practical implementation, 2016, pp.60, 72~84
  11. Kim DY, "Reproducibility of different arrangement of resin copings by dental microstereolithography : evaluating the marginal discrepancy of resin copings", J Prosthet Dent, 117, pp.260~265 (2017)
  12. Shamseddine L, "Fit of pressed crowns fabricated from two CAD-CAM wax pattern process plans : a comparative in vitro study", J Prosthet Dent, 118, pp.49~54 (2017)
  13. van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)
  14. Galante R, "Additive manufacturing of ceramics for dental applications : a review", Dent Mater, 35, pp.825~846 (2019)
  15. Stansbury JW, "3D printing with polymers : Challenges among expanding options and opportunities", Dent Mater, 32, pp.54~64 (2016)
  16. Osman RB, "Build Angle : Does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology", Int J Prosthodont, 30, pp.182~188 (2017)
  17. Alharbi N, "Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology", Int J Prosthodont, 29, pp.503~510 (2016)
  18. Park GS, "Effects of printing parameters on the fit of implant-supported 3D printing resin prosthetics", Materials(Basel), 12, pp.2533~ (2019)
  19. Karalekas D, "Study of shrinkage strains in a stereolithography cured acrylic photopolymer resin", J Mater Process Technol, 136, pp.146~150 (2003)
  20. Katheng A, "Evaluation of dimensional accuracy and degree of polymerization of stereolithography photopolymer resin under different postpolymerization conditions : an in vitro study", J Prosthet Dent (2020)
  21. Kim J, "Influence of the postcuring process on dimensional accuracy and seating of 3D-printed polymeric fixed prostheses", Biomed Res Int, 2020, pp.2150182~ (2020)
  22. Kalberer N, "CAD-CAM milled versus rapidly prototyped(3D-printed)complete dentures : an in vitro evaluation of trueness", J Prosthet Dent, 121, pp.637~643 (2019)
  23. Yoon HI, "Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing", J Prosthet Dent, 120, pp.919~926 (2018)
  24. 전진훈, "Trueness and precision of scanning abutment impressions and stone models according to dental CAD", CAM evaluation standards, 2018, pp.10(5), 335~339[DOI]
  25. Kang SY, "Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design", manufacturing system : an in vitro study, 2020, pp.64, 152~158
  26. Wang W, "Trueness analysis of zirconia crowns fabricated with 3-dimensional printing", J Prosthet Dent, 121, pp.285~291 (2019)
  27. Bosch G, "A 3-dimensional accuracy analysis of chairside CAD", CAM milling processes, 2014, pp.112, 1425~1431
  28. Shah S, "The use of a 3D laser scanner using superimpositional software to assess the accuracy of impression techniques", J Dent, 32, pp.653~658 (2004)
  29. "ISO 12836. Dentistry digitizing devices for CAD/CAM systems for indirect dental restorations - test methods for assessing accuracy" (2012)[URL]
  30. You SM, "Evaluation of the accuracy(trueness and precision)of a maxillary trial denture according to the layer thickness : an in vitro study", J Prosthet Dent, 125, pp.139~145 (2020)
  31. Suji Lee, "Comparing accuracy of denture bases fabricated by injection molding, CAD", CAM milling, and rapid prototyping method, 2019, pp.11(1), 55~64[DOI]
  32. American Dental Association, "Guide to dental materials and devices", pp.87~88 (1970), American Dental Association
  33. Sherman SL, "Accuracy of digital light processing printing of 3-dimensional dental models", J Am Dent Assoc, 157, pp.422~428 (2020)
  34. 전진훈, "Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner", The Journal of Advanced of Prosthodontics, 8(3), pp.214~218 (2016), 대한치과보철학회[DOI]
  35. Martorelli M, "A comparison between customized clear and removable orthodontic appliances manufactured using RP and CNC techniques", Dent Mater, 29, pp.e1~e10 (2013)
  36. Patzelt SB, "Accuracy of computer-aided design", computer-aided manufacturing-generated dental casts based on intraoral scanner data, 2014, pp.145, 1133~1140
  37. Al-Imam H, "Accuracy of stereolithography additive casts used in a digital workflow", J Prosthet Dent, 119, pp.580~585 (2018)
  38. Loflin WA, "Effect of print layer height on the assessment of 3D-printed models", Am J Orthod Dentofacial Orthop, 156, pp.283~289 (2019)
  39. Kirsch C, "Trueness of four different milling procedures used in dental CAD", CAM systems, 2017, pp.21, 551~558
  40. Bae SY, "Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone(PEKK)and zirconia", J Prosthodont Res, 61, pp.106~112 (2017)
  41. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
  42. 박진영, "Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis", The Journal of Advanced of Prosthodontics, 9(3), pp.159~169 (2017), 대한치과보철학회[DOI]
  43. You SM, "Evaluation of trueness in a denture base fabricated by using CAD-CAM systems and adaptation to the socketed surface of denture base : An in vitro study", J Prosthet Dent (2020)
  44. Lehmann KM, "The effect of optical conditioning of preparations with scan spray on preparation form", Acta Stomatol Croat, 45, pp.86~92 (2011)
  45. You SG, "Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems : an in vitro study", J Prosthet Dent (2020)

관련 논문AI추천

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study김동연, 김지환, 유승규, 유승민, 이범일대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system이규복, 이두형, 이완선대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제4호Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique강신영, 김웅철, 김지환, 박정현대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호Marginal and internal fit of 3D printed provisional crowns according to build directions공현준, 김유리, 류지은, 장훈상, 정지혜대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제4호Evaluation of the marginal and internal fit of a single crown fabricated based on a threedimensional printed model장연, 김웅철, 김지환, 김혜영, 박종경, 심지영대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호The comparison of the accuracy of temporary crowns fabricated with several 3D printers and a milling machine김지형, 안진수, 이준식, 주성원, 황시언대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제2호

이 간행물의 다른 논문 (6건)