본문 바로가기
KERD
논문KCI 등재

Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 μm in group CF and 34 ± 6 μm in group PC. RMSE of total adjustments was 61 ± 11 μm in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.

Abstract

PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 μm in group CF and 34 ± 6 μm in group PC. RMSE of total adjustments was 61 ± 11 μm in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.

참고문헌 (34)

  1. van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)
  2. Mühlemann S, "Is the use of digital technologies for the fabrication of implant-supported reconstructions more efficient and", or more effective than conventional techniques:A systematic review, 2018, pp.29, 184~195
  3. Schubert O, "Digital implant planning and guided implant surgery – workflow and reliability", Br Dent J, 226, pp.101~108 (2019)
  4. Ender A, "Accuracy of complete-and partial-arch impressions of actual intraoral scanning systems in vitro", Int J Comput Dent, 22, pp.11~19 (2019)
  5. Hasanzade M, "In vivo and in vitro comparison of internal and marginal fit of digital and conventional impressions for full-coverage fixed restorations: a systematic review and meta-analysis", J Evid Based Dent Pract, 19, pp.236~254 (2019)
  6. Joda T, "Time-efficiency analysis comparing digital and conventional workflows for implant crowns: a prospective clinical crossover trial", Int J Oral Maxillofac Implants, 30, pp.1047~1053 (2015)
  7. Ahlholm P, "Digital versus conventional impressions in fixed prosthodontics:a review", J Prosthodont, 27, pp.35~41 (2018)
  8. Sawase T, "The current clinical relevancy of intraoral scanners in implant dentistry", Dent Mater J, 39, pp.57~61 (2020)
  9. Motel C, "Impact of different scan bodies and scan strategies on the accuracy of digital implant impressions assessed with an intraoral scanner : an in vitro study", J Prosthodont, 29, pp.309~314 (2020)
  10. Michelinakis G, "The direct digital workflow in fixed implant prosthodontics : a narrative review", BMC Oral Health, 21, pp.37~ (2021)
  11. Shimizu S, "The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses", Dent Mater J, 36, pp.402~407 (2017)
  12. Revilla-León M, "Additive manufacturing technologies used for processing polymers : current status and potential application in prosthetic dentistry", J Prosthodont, 28, pp.146~158 (2019)
  13. Schweiger J, "3D printing in digital prosthetic dentistry : an overview of recent developments in additive manufacturing", J Clin Med, 10, pp.2010~ (2021)
  14. Emir F, "Accuracy evaluation of complete-arch models manufactured by three different 3D printing technologies : a three-dimensional analysis", J Prosthodont Res, 65, pp.365~370 (2021)
  15. Park ME, "Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers", J Prosthet Dent, 119, pp.861.e1~861.e7 (2018)
  16. Buda M, "Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts", J Prosthet Dent, 120, pp.913~918 (2018)
  17. Revilla-León M, "Position accuracy of implant analogs on 3d printed polymer versus conventional dental stone casts measured using a coordinate measuring machine", J Prosthodont, 27, pp.560~567 (2018)
  18. Maria R, "Accuracy of implant analogs in 3d printed resin models", J Prosthodont, 30, pp.57~64 (2021)
  19. Revilla-León M, "Influence of scan body design and digital implant analogs on implant replica position in additively manufactured casts", J Prosthet Dent, 124, pp.202~210 (2020)
  20. Zhang Y, "Quantitative clinical adjustment analysis of posterior single implant crown in a chairside digital workflow : A randomized controlled trial", Clin Oral Implants Res, 30, pp.1059~1066 (2019)
  21. Joda T, "Complete digital workflow for the production of implant-supported single-unit monolithic crowns", Clin Oral Implants Res, 25, pp.1304~1306 (2014)
  22. Joda T, "Clinical fitting and adjustment time for implant-supported crowns comparing digital and conventional workflows", Clin Implant Dent Relat Res, 18, pp.946~954 (2016)
  23. Joda T, "Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow : a randomized controlled trial", Clin Oral Implants Res, 27, pp.1401~1406 (2016)
  24. Pan S, "Time efficiency and quality of outcomes in a model-free digital workflow using digital impression immediately after implant placement : A double-blind self-controlled clinical trial", Clin Oral Implants Res, 30, pp.617~626 (2019)
  25. Di Fiore A, "Digital vs conventional workflow for screw-retained single-implant crowns: a comparison of key considerations", Int J Prosthodont, 31, pp.577~579 (2018)
  26. Joda T, "Digital vs. conventional implant prosthetic workflows: a cost", time analysis, 2015, pp.26, 1430~1435
  27. Hamm J, "Evaluation of model materials for CAD", CAM in vitro studies, 2020, pp.23, 49~56
  28. Dupagne L, "Comparison of the acquisition accuracy and digitizing noise of 9 intraoral and extraoral scanners : An objective method", J Prosthet Dent (2021)
  29. Passent Ellakany, "Evaluation of the Accuracy of Digital Impressions Obtained from Intraoral and Extraoral Dental Scanners with Different CAD", CAM Scanning Technologies: An In Vitro Study, 2021, ~[DOI]
  30. Semper-Hogg W, "Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection", Clin Oral Investig, 17, pp.1017~1023 (2013)
  31. Hogg WS, "The influence of torque tightening on the position stability of the abutment in conical implant-abutment connections", Int J Prosthodont, 28, pp.538~541 (2015)
  32. Oh KC, "Accuracy of three digitization methods for the dental arch with various tooth preparation designs : an in vitro study", J Prosthodont, 28, pp.195~201 (2019)
  33. Kim Y, "Occlusal considerations in implant therapy : clinical guidelines with biomechanical rationale", Clin Oral Implants Res, 16, pp.26~35 (2005)
  34. Warreth A, "Fundamentals of occlusion and restorative dentistry. Part II: occlusal contacts, interferences and occlusal considerations in implant patients", J Ir Dent Assoc, 61, pp.252~259 (2015)

관련 논문AI추천

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system이규복, 이두형, 이완선대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제4호Evaluation of the marginal and internal fit of a single crown fabricated based on a threedimensional printed model장연, 김웅철, 김지환, 김혜영, 박종경, 심지영대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study김웅철, 김지환, 김총명, 박진영, 정일도대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제4호The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preloadHanan Nejer Alotaibi, Shahad Mohammmed Altuwaijri, Talal Mughaileth Alnassar대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제1호Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical studyAgne Gedrimiene, Rimas Adaskevicius, Vygandas Rutkunas대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제5호Comparison of marginal and internal fit of zirconia crowns fabricated by three-dimensional printing with different offset parameters: A preliminary pilot study김소연, 김욱태, 이규복, 이지민, 장경준, 손큰바다대한치과의사협회 · 대한치과의사협회지2025 · 제63권 제5호

이 간행물의 다른 논문 (5건)