Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and dist al implant scan bodies (P≤.05). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.
Abstract
PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and dist al implant scan bodies (P≤.05). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.
참고문헌 (34)
- Joda T, "Clinical fitting and adjustment time for implant-supported crowns comparing digital and conventional workflows", Clin Implant Dent Relat Res, 18, pp.946~954 (2016)
- Baig MR, "Accuracy of impressions of multiple implants in the edentulous arch : a systematic review", Int J Oral Maxillofac Implants, 29, pp.869~880 (2014)
- Mormann WH, "CAD-CAM ceramic inlays and onlays : a case report after 3years in place", J Am Dent Assoc, 120, pp.517~520 (1990)
- Zarauz C, "Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions", Clin Oral Investig, 20, pp.799~806 (2016)
- Rutkūnas V, "Accuracy of digital implant impressions with intraoral scanners. A systematic review", Eur J Oral Implantol, 10, pp.101~120 (2017)
- Biagioni A, "A systematic review about randomized clinical trials on digital impressions on sound teeth", J Osseointegration, 11, pp.2~6 (2019)
- Flügge T, "The accuracy of different dental impression techniques for implant-supported dental prostheses : A systematic review and meta-analysis", Clin Oral Implants Res, 29, pp.374~392 (2018)
- Cappare P, "Conventional versus digital impressions for full arch screw-retained maxillary rehabilitations : A randomized clinical trial", Int J Environ Res Public Health, 16, pp.829~ (2019)
- Alsharbaty MHM, "A clinical comparative study of 3-dimensional accuracy between digital and conventional implant impression techniques", J Prosthodont, 28, pp.e902~e908 (2019)
- Andriessen FS, "Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles : a pilot study", J Prosthet Dent, 111, pp.186~194 (2014)
- Rutkunas V, "A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin", J Prosthet Dent, 111, pp.254~256 (2014)
- Abduo J, "Assessing the fit of implant fixed prostheses : a critical review", Int J Oral Maxillofac Implants, 25, pp.506~515 (2010)
- Flügge TV, "Precision of dental implant digitization using intraoral scanners", Int J Prosthodont, 29, pp.277~283 (2016)
- Gherlone EF, "Digital impressions for fabrication of definitive “all-on-four”restorations", Implant Dent, 24, pp.125~129 (2015)
- Venezia P, "Digital registration of peri-implant transmucosal portion and pontic area in the esthetic zone", J Osseointegration, 9, pp.312~316 (2017)
- Abduo J, "Fit of CAD", CAM implant frameworks : a comprehensive review, 2014, pp.40, 758~766
- Beuer F, "Digital dentistry : an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204, 505~511
- Kohorst P, "Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design", computer-aided manufacturing systems, 2009, pp.117, 319~325
- Papaspyridakos P, "Accuracy of implant impressions for partially and completely edentulous patients : a systematic review", Int J Oral Maxillofac Implants, 29, pp.836~845 (2014)
- Brånemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
- Jemt T, "Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws : a study of treatment from the time of prosthesis placement to the first annual checkup", Int J Oral Maxillofac Implants, 6, pp.270~276 (1991)
- Katsoulis J, "Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature", Eur J Oral Implantol, 10, pp.121~138 (2017)
- Karl M, "Bone adaptation induced by non-passively fitting implant superstructures : A randomized clinical trial", Int J Oral Maxillofac Implants, 31, pp.369~375 (2016)
- Nedelcu R, "Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions : A novel in vivo analysis method", J Dent, 69, pp.110~118 (2018)
- Semper W, "Impact of abutment rotation and angulation on marginal fit : theoretical considerations", Int J Oral Maxillofac Implants, 25, pp.752~758 (2010)
- Alikhasi M, "A comparison of precision of fit, rotational freedom, and torque loss with copy-milled zirconia and prefabricated titanium abutments", Int J Oral Maxillofac Implants, 28, pp.996~1002 (2013)
- Flügge TV, "Precision of dental implant digitization using intraoral scanners", Int J Prosthodont, 29, pp.277~283 (2016)
- Papaspyridakos P, "Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients : an optical scanning study", Clin Oral Implants Res, 23, pp.676~681 (2012)
- Tan MY, "Comparison of three-dimensional accuracy of digital and conventional implant impressions : Effect of interimplant distance in an edentulous arch", Int J Oral Maxillofac Implants, 34, pp.366~380 (2019)
- "Accuracy of computerized and conventional impression-making procedures of straight and tilted dental implants" (2015)[URL]
- Giménez B, "Accuracy of a digital impression system based on active triangulation technology with blue light for implants : Effect of clinically relevant parameters", Implant Dent, 24, pp.498~504 (2015)
- Gimenez-Gonzalez B, "An in vitro study of factors influencing the performance of digital intraoral impressions operating on active wavefront sampling technology with multiple implants in the edentulous maxilla", J Prosthodont, 26, pp.650~655 (2017)
- Müller P, "Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner", Quintessence Int, 47, pp.343~349 (2016)
- Stimmelmayr M, "Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study", Clin Oral Investig, 16, pp.851~856 (2012)