Evaluation of the marginal and internal fit of a single crown fabricated based on a threedimensional printed model
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the “Best-fit alignment” method using the analysis software. Oneway and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (α=.05). Tukey’s HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<120 μm).
Abstract
PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the “Best-fit alignment” method using the analysis software. Oneway and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (α=.05). Tukey’s HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<120 μm).
참고문헌 (27)
- van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)[DOI]
- Yau HT, "Comparison of 3-D printing and 5-axis milling for the production of dental e-models from intra-oral scanning", Comput Aided Des Appl, 13, pp.32~38 (2016)[DOI]
- Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)[DOI]
- Cho SH, "Comparison of accuracy and reproducibility of casts made by digital and conventional methods", J Prosthet Dent, 113, pp.310~315 (2015)[DOI]
- Ueda K, "Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions", Clin Oral Investig, 20, pp.283~289 (2016)[DOI]
- Fransson B, "The fit of metal-ceramic crowns, a clinical study", Dent Mater, 1, pp.197~199 (1985)[DOI]
- Karlsson S, "The fit of Procera titanium crowns. An in vitro and clinical study", Acta Odontol Scand, 51, pp.129~134 (1993)[DOI]
- Hwang YC, "The evaluation of working casts prepared from digital impressions", Oper Dent, 38, pp.655~662 (2013)[DOI]
- Pfeiffer J, "Dental CAD", CAM technologies: the optical impression (I), 1998, pp.1, 29~33
- Sun J, "The application of rapid prototyping in prosthodontics", J Prosthodont, 21, pp.641~644 (2012)[DOI]
- Dawood A, "3D printing in dentistry", Br Dent J, 219, pp.521~529 (2015)[DOI]
- Schaefer O, "Effect of CNC-milling on the marginal and internal fit of dental ceramics: a pilot study", Dent Mater, 29, pp.851~858 (2013)[DOI]
- Anadioti E, "3D and 2D marginal fit of pressed and CAD", CAM lithium disilicate crowns made from digital and conventional impressions, 2014, pp.23, 610~617
- Anadioti E, "Internal fit of pressed and computer-aided design", computer-aided manufacturing ceramic crowns made from digital and conventional impressions, 2015, pp.113, 304~309
- Keating AP, "A comparison of plaster, digital and reconstructed study model accuracy", J Orthod, 35, pp.191~201 (2008)[DOI]
- Schaefer O, "Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility", Dent Mater, 28, pp.320~326 (2012)[DOI]
- Ortorp A, "The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study", Dent Mater, 27, pp.356~363 (2011)[DOI]
- Chochlidakis KM, "Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis", J Prosthet Dent, 116, pp.184~190 (2016)[DOI]
- McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)[DOI]
- Ucar Y, "Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns", J Prosthet Dent, 102, pp.253~259 (2009)[DOI]
- Seelbach P, "Accuracy of digital and conventional impression techniques and workflow", Clin Oral Investig, 17, pp.1759~1764 (2013)[DOI]
- Kim CM, "Trueness of milled prostheses according to number of ball-end mill burs", J Prosthet Dent, 115, pp.624~629 (2016)[DOI]
- Mously HA, "Marginal and internal adaptation of ceramic crown restorations fabricated with CAD", CAM technology and the heatpress technique, 2014, pp.112, 249~256
- Hoang LN, "Die spacer thickness reproduction for central incisor crown fabrication with combined computer-aided design and 3D printing technology: an in vitro study", J Prosthet Dent, 113, pp.398~404 (2015)[DOI]
- Kale E, "Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns", J Prosthet Dent, 116, pp.890~895 (2016)[DOI]
- Shim JS, "Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD", CAM system, 2015, pp.23, 515~522
- Boitelle P, "3D fitting accuracy evaluation of CAD", CAM copings - comparison with spacer design settings, 2016, pp.19, 27~43
