PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student’s t-test (α=.05). RESULTS. The RMS value of lithium disilicate crown was 29.2 (4.1) µm and 17.6 (5.5) µm on the outer and inner surfaces, respectively, whereas these values were 18.6 (2.0) µm and 20.6 (5.1) µm for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

Abstract

PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student’s t-test (α=.05). RESULTS. The RMS value of lithium disilicate crown was 29.2 (4.1) µm and 17.6 (5.5) µm on the outer and inner surfaces, respectively, whereas these values were 18.6 (2.0) µm and 20.6 (5.1) µm for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

참고문헌 (23)

  1. Beuer F, "Digital dentistry: an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204, 505~511
  2. Henkel GL, "A comparison of fixed prostheses generated from conventional vs digitally scanned dental impressions", Compend Contin Educ Dent, 28, pp.422~424 (2007)
  3. Raigrodski AJ, "Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature", J Prosthet Dent, 92, pp.557~562 (2004)
  4. Schaefer O, "Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro", J Dent, 42, pp.677~683 (2014)
  5. Schaefer O, "Effect of CNC-milling on the marginal and internal fit of dental ceramics: a pilot study", Dent Mater, 29, pp.851~858 (2013)
  6. Stookey SD, "Catalyzed crystallization of glass in theory and practice", Ind Eng Chem, 51, pp.805~808 (1959)
  7. McMillan PW, "The structure and properties of a lithium zinc silicate glass-ceramic", J Mater Sci, 1, pp.269~279 (1966)
  8. Freiman SW, "Effect of Crystallization on the Mechanical Properties of Li2O-SiO2 Glass-Ceramics", J Am Ceram Soc, 55, pp.86~90 (1972)
  9. Anusavice KJ, "Influence of colorants on crystallization and mechanical properties of lithiabased glass-ceramics", Dent Mater, 10, pp.141~146 (1994)
  10. Lupu M, "Flexural strength of CAD", CAM ceramic framework materials, 2007, pp.88, 224~
  11. Batson ER, "Clinical outcomes of three different crown systems with CAD", CAM technology, 2014, pp.112, 770~777
  12. Coldea A, "Hertzian contact response and damage tolerance of dental ceramics", J Mech Behav Biomed Mater, 34, pp.124~133 (2014)
  13. Denry I, "Ceramics for dental applications: a review", Materials, 3, pp.351~368 (2010)
  14. Filser F, "Net-shaping of ceramic components by direct ceramic machining", Assembly Autom, 23, pp.382~390 (2003)
  15. Hamza TA, "Accuracy of ceramic restorations made with two CAD", CAM systems, 2013, pp.109, 83~87
  16. Patzelt SB, "Accuracy of full-arch scans using intraoral scanners", Clin Oral Investig, 18, pp.1687~1694 (2014)
  17. "ISO-5725-1. Accuracy (Trueness and Precision) of Measurement Methods and Results ? Part 1: General Principles and Definitions" (1994)[URL]
  18. "ISO-12836. Digitizing devices for CAD/CAM systems for indirect dental restorations - Test methods for assessing accuracy" (2012)[URL]
  19. Bosch G, "A 3-dimensional accuracy analysis of chairside CAD", CAM milling processes, 2014, pp.112, 1425~1431
  20. Wiedhahn K, "Cerec Omnicam -Intraoralscan 2.0", Int J Comput Dent, 15, pp.199~205 (2012)
  21. Poticny DJ, "CAD", CAM in-office technology: innovations after 25 years for predictable, esthetic outcomes, 2010, pp.141, 5S~9S
  22. Schaefer O, "Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility", Dent Mater, 28, pp.320~326 (2012)
  23. Addison O, "Machining variability impacts on the strength of a ‘chair-side’ CAD-CAM ceramic", Dent Mater, 28, pp.880~887 (2012)

관련 논문AI추천

Comparison of three-dimensional digital technique with twodimensional replica method for measuring marginal and internal fit of full coverage restorationsMahya Hasanzade, Marzieh Alikhasi, Naeime Moslemian, Soudabeh Koulivand대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicasAntonio Minarro Alonso, Estefania Aranda Yus, Josep Maria Anglada Cantarell대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제3호Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods조진현, 최현석대한치과보철학회 · 대한치과보철학회지2017 · 제55권 제2호In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologiesÇise Özal, Mutahhar Ulusoy대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제6호Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown박상원, 박지희, 오계정, 윤귀덕, 임현필, 지민경대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제4호How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materialsMahya Hasanzade, Marzieh Alikhasi, Mohammad Moharrami대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제6호