본문 바로가기
KERD
논문KCI 등재

IEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (Ⅰ)

Evaluation of Image Receptor Characteristics in Computed Radiography System Using Exposure Index in International Electrotechnical Commission (Ⅰ)

2

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The International Electrotechnical Commission (IEC) has regulated the definition and requirements of the exposure index (EI). In this study, we calculated the EI of several image receptors in digital radiography system of two different manufacturers according to the method as per IEC, and evaluated the relationship with incident air kerma. To calculate t he E I, w e obtained the characteristics curve of e ach i mage receptor b y increasing t he i ncident air kerma at R QA 3, 5, 7 and 9, respectively. As a result, there was no significant difference in the EI values between different image receptors of the same manufacturer, but EI values of different manufacturer was different despite the same air kerma was incident. Therefore, understanding the characteristics of the digital radiography systems is important in order to use EI as a tool for measuring and managing the radiation dose.

Abstract

The International Electrotechnical Commission (IEC) has regulated the definition and requirements of the exposure index (EI). In this study, we calculated the EI of several image receptors in digital radiography system of two different manufacturers according to the method as per IEC, and evaluated the relationship with incident air kerma. To calculate t he E I, w e obtained the characteristics curve of e ach i mage receptor b y increasing t he i ncident air kerma at R QA 3, 5, 7 and 9, respectively. As a result, there was no significant difference in the EI values between different image receptors of the same manufacturer, but EI values of different manufacturer was different despite the same air kerma was incident. Therefore, understanding the characteristics of the digital radiography systems is important in order to use EI as a tool for measuring and managing the radiation dose.

참고문헌 (20)

  1. Doi K, "Diagnostic image over the last 50 years: research and development in medical imaging science and technology", Phys Med Biol, 51, pp.R5~R27 (2006)
  2. Seo DN, "A comparative assesment of entrance surface doses in analogue and digital radiography during common radiographic examinations", Radiat Prot Dosimetry, 158, pp.22~27 (2014)
  3. 김정수, "영상의학검사 일반촬영 분야의 촬영기법에 대한 분석", 방사선기술과학, 37(3), pp.169~175 (2014), 대한방사선과학회
  4. Yoon YS, "Monte Carlo simulation-based feasibility sudy of a dose-area product meter built into a collimator for diagnostic X-ray", Radiat Prot Dosimetry, 162, pp.421~426 (2014)
  5. Seibert JA, "The standardized exposure index for digital radiography : an opportunity for optimization of radiation dose to the pediatric population", Pediatr Radiol, 41, pp.573~581 (2011)
  6. Shepard SJ, "An exposure indication for digital radiography : AAPM Task Group 116(Executive Summary)", Med Phys, 36, pp.2898~2914 (2009)
  7. "IEC 60601-1-3, Ed 2.0. Medical e lectrical equipment - Part 1-3: General requirements for basic safety and essential performance – Collateral Standard:Radiation protection in diagnostic X-ray equipment", International Electrotechnical Commission, ~ (2008)
  8. 이호선, "국산 프로토타입 면적선량계 SFT-1의 성능평가", 방사선기술과학, 39(3), pp.435~441 (2016), 대한방사선과학회[DOI]
  9. 김정수, "Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea", 방사선기술과학, 39(1), pp.27~33 (2016), 대한방사선과학회[DOI]
  10. Kim JS, "Real-time patient radiation dose monitoring system used in a large university hospital", Journal of Digit Imaging, 29, pp.627~634 (2016)
  11. Kim JS, "Development of diagnostic reference levels using a real-time radiation dose monitoring system at a cardiovascular center in Korea", Journal of Digit Imaging, 28, pp.684~694 (2015)
  12. An exposure indicator for digital radiography, "AAPM", American Association of Physicists in Medicine, ~, pp.REPORT NO.116 (2009)
  13. Moore QT, "Image gently : using exposure indicators to improve pediatric digital radiography", Radiol Technol, 84, pp.93~99 (2012)
  14. Yasumatsu S, "Effect of X-ray beam quality on determination of exposure index", Radiol Phys Technol, 9, pp.109~115 (2016)
  15. "IEC 62494-1, Ed 1.0. Medical e lectrical e quipment – Exposure index of digital X-ray imaging system – Part 1: Definitions and requirements for general radiography", International Electrotechnical Commission, ~ (2008)
  16. "IEC 61267, Ed 1.0. Medical diagnostic X-ray equipment – Radiation conditions for use in the determination of characteristics", International Electrotechnical Commission, ~ (1994)
  17. Kunitomo H, "Concept and application method of new index “exposure index: EI” for dose evaluation between devices", Innervision, 27, pp.14~18 (2012)
  18. Rosner B, "Fundamentals of Biostatistics" (2015), Cengage Learning
  19. Kong KA, "Statistical methods: reliability assessment and method comparison", Ewha Med J, 40(1), pp.9~16 (2017)
  20. 정회원, "인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구", 방사선기술과학, 41(6), pp.533~538 (2018), 대한방사선과학회[DOI]

관련 논문AI추천