인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구

A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom

1

조회

0

다운로드

6

인용

0

참고문헌

키워드

주제분류방사선과학

초록

As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

Abstract

As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

참고문헌 (16)

  1. 김정수, "영상의학검사 일반촬영 분야의 촬영기법에 대한 분석", 방사선기술과학, 37(3), pp.169~175 (2014), 대한방사선과학회
  2. "Managing patient dose in digital radiology" (2003)
  3. International Electrotechnical Commission(IEC), "IEC 62494-1" (2008)
  4. Kishimoto K, "Study of Appropriate Dosing in Consideration of Image Quality and Patient Dose on the Digital Radiography", Japanese Journal of Radiological Technology, 67(11), pp.1381~1397 (2011)
  5. 손순룡, "Measurement of Image Quality According to the Time of Computed Radiography System", 방사선기술과학, 38(4), pp.365~374 (2015), 대한방사선과학회[DOI]
  6. 김기원, "컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가", 방사선기술과학, 39(2), pp.193~198 (2016), 대한방사선과학회[DOI]
  7. 김기원, "유방영상에서 엣지를 이용한 물리적 영상 평가", 방사선기술과학, 39(3), pp.415~420 (2016), 대한방사선과학회[DOI]
  8. Schaetzing R., "Computed radiography technology", Proceeding of Radiological Society of North America, 10 (2003)
  9. Dobbins JT, "DQE (f) of four generations of computed radiography acquisition devices", Med. Phys, 22(10), pp.1581~1593 (1995)
  10. Antonuk LE, "Demonstration of megavoltage and diagnostic X-ray imaging with hydrogenated amorphous silicon arrays", Med. Phys, 19(6), pp.1455~1466 (1992)
  11. International Electrotechnical Commission(IEC), "Medical electrical equipment Characteristics of digital X-ray imaging devices Part 1: determination of the detective quantum efficiency" (2003)
  12. 정회원, "CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가", 방사선기술과학, 35(2), pp.109~117 (2012), 대한방사선과학회[DOI]
  13. 정회원, "다양한 디지털 방사선 시스템의 물리적 영상 특성 조사", 방사선기술과학, 40(3), pp.363~370 (2017), 대한방사선과학회[DOI]
  14. Ariga E, "Evaluation of Calibration Error for Applying Exposure Index", Japanese Journal of Radiological Technology, 67(11), pp.1433~1437 (2011)
  15. Nakamae M, "Influence of Interest Region and Interest Value Settings on Exposure Index Analysis Using Chest Clinical Images", Japanese Journal of Radiological Technology, 70(11), pp.1250~1257 (2014)
  16. Willis CE., "Categorical Course in Physics:Technology Update and Quality Improvement of Diagnostic X-ray Imaging Equipment", pp.153~160 (1996), Radiological Society of North America Publication (RSNA)

관련 논문AI추천

이 간행물의 다른 논문 (15건)