진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구
A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.
Abstract
The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.
참고문헌 (17)
- 김정수, "영상의학검사 일반촬영 분야의 촬영기법에 대한 분석", 방사선기술과학, 37(3), pp.169~175 (2014), 대한방사선과학회
- Doi K, "Diagnostic image over the last 50 years:Research and development in medical imaging science and technology", Phys Med Biol, 51, pp.R5~R7 (2006)
- Seo DN, "A comparative assessment of entrance surface doses in analogue and digital radiography during common radiographic examinations", Radiat Prot Dosimetry, 158, pp.22~27 (2014)
- Cohen MD, "Quality assurance: Using the exposure index and the deviation index to monitor radiation exposure for portable chest radiographs in neonates", Pediatr. Radiol, 41, pp.592~601 (2011)
- 정회원, "인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구", 방사선기술과학, 41(6), pp.533~538 (2018), 대한방사선과학회[DOI]
- An exposure indicator for digital radiography, , American Association of Physicists in Medicine, ~, pp.AAPM Report NO 116 (2009)
- Park HM, "Use of clinical exposure index and deviation index based on national diagnostic reference level as dose-optimization tools for general radiography in Korea", Radiat Prot Dosimetry, 191, pp.439~451 (2020)
- "IEC 62494-1, Ed 1.0. Medical electrical equipment-Exposure index of digital X-ray imaging system-Part 1: Definitions and requirements for general radiography", International Electrotechnical Commission, ~ (2008)
- 박혜민, "IEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (Ⅰ)", 방사선기술과학, 42(4), pp.291~299 (2019), 대한방사선과학회
- Park HM, "Feasibility of displayed exposure index in IEC standard framework as a dose optimisation tool for digital radiography systems", Radiat Prot Dosimetry, 189, pp.384~394 (2020)
- Managing patient dose in digital radiology, , International Commission on Radiological Protection, ~, pp.ICRP Publication 60 (1991)
- Diagnostic reference levels in medical imaging, , International Commission on Radiological Protection, ~, pp.ICRP Publication 135 (2017)
- "KFDA Radiation Safety Management Series No. 30. Guideline for diagnostic reference levels in general radiography", Korea Food & Drug Administration, ~ (2012)
- "KCDC Medical Radiation Series No. 16. Guideline for diagnostic reference levels", Korea Centers for Disease control and Prevention, ~ (2019)
- Development of the diagnostic reference level of general radiography: Twelve area including brain, chest, pelvis, etc, "Do KH", Korea Centers for Disease control and Prevention, ~, pp.Research Report No.11-1352159-000916-01 (2017)
- The Korean Society of Medical Imaging Technology, "Textbook of radiographic positioning and clinical diagnosis" (2019), Chung Ku Publisher
- Seeram E, "Radiation dose optimization research : Exposure technique approaches in CR imaging-A literature review", Radiography, 19(4), pp.331~338 (2013)