초록

Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.

Abstract

Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.

참고문헌 (14)

  1. 장새별, "백굴채 추출물이 MDA-MB-231 유방암 세포주에서 세포사멸에 미치는 효과", 대한한방부인과학회지, 28(2), pp.15~25 (2015), 대한한방부인과학회[DOI]
  2. 김경옥, "일반인과 유방암 환자간의 식행동 및 영양정보에 관한 인식조사", Journal of Nutrition and Health, 46(3), pp.250~260 (2013), 한국영양학회[DOI]
  3. Lee EH, "A Study on the Effectiveness of Stereotactic Mammotome Biopsy using Needle Guidy", The Korean Society of Radiologic Imaging Technology, 13(1), pp.149~156 (2016)
  4. Jeong SJ, "The Knowledge and Practice of the Breast Self-examination in Women sho got gealth check up", Journal of Preventive Medicine and Public Health, 31(4), pp.740~750 (1998)
  5. 남석진, "유방암의 검진 및 진단", 대한의사협회지, 52(10), pp.946~951 (2009), 대한의사협회
  6. 송교혁, "맘모그램 영상처리를 이용한 종양검출 알고리즘", 한국생산제조학회지, 22(3), pp.496~503 (2013), 한국생산제조학회[DOI]
  7. 홍동희, "유방촬영장치의 압박대 재질을 고려한 투과선량 평가", 한국콘텐츠학회 논문지, 15(11), pp.307~312 (2015), 한국콘텐츠학회[DOI]
  8. 홍동희, "유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구", 방사선기술과학, 38(2), pp.81~87 (2015), 대한방사선과학회[DOI]
  9. 홍동희, "유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가", 방사선기술과학, 38(3), pp.229~235 (2015), 대한방사선과학회[DOI]
  10. Yun NR, "A Study of X-ray Detection Ability in Disease Using Manufactured Breast Phantom", Journal of Advanced Engineering and Technology, 3(3), pp.305~309 (2010)
  11. Kim DB, "Artifacts on Screen-Film Mammography: Types and Solutions", Journal of the Korean Society for Breast Screening, 4, pp.12~19 (2007)
  12. Kim DH, "A Study of the Utility of Radiolucent Mammo pad in Mammography", The Korean Society of Radiologic Imaging Technology, 7, pp.9~17 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (6건)