In order to protect human lives from disease, various biosensors having the potential to analyze a variety of biomolecules have been utilized. Biosensors constitute one of the most promising ways to monitor and detect various biomolecules corresponding to diseases. In this study, we demonstrate that the reaction of streptavidin molecules with biotin on a gold electrode can be detected using the twoelectrode method with a gold electrode and a platinum reference electrode. We also show the characteristics of the electrical current response. While detecting 2-μM streptavidin molecules dissolved in phosphate buffered saline(PBS) solution, we found that an analytical biosensor can operate on the principle of detecting an antigen-antibody reaction event of protein molecules using the two-electrode method. We think that the “potential step” method might be useful to detect the occurrence of any antigen-antibody reactions and can be combined with other devices or ICs such as BJTs, MOSFETs, and OP-amps for the detection of biomolecules of diseases.
Abstract
In order to protect human lives from disease, various biosensors having the potential to analyze a variety of biomolecules have been utilized. Biosensors constitute one of the most promising ways to monitor and detect various biomolecules corresponding to diseases. In this study, we demonstrate that the reaction of streptavidin molecules with biotin on a gold electrode can be detected using the twoelectrode method with a gold electrode and a platinum reference electrode. We also show the characteristics of the electrical current response. While detecting 2-μM streptavidin molecules dissolved in phosphate buffered saline(PBS) solution, we found that an analytical biosensor can operate on the principle of detecting an antigen-antibody reaction event of protein molecules using the two-electrode method. We think that the “potential step” method might be useful to detect the occurrence of any antigen-antibody reactions and can be combined with other devices or ICs such as BJTs, MOSFETs, and OP-amps for the detection of biomolecules of diseases.
참고문헌 (12)
- C. L. Morgan, "Immunosensors:technology and opportunities inlaboratory medicine", Clinical Chemistry, 42(2), pp.193~209 (1996)
- M. Pedrero, "Electroanalytical sensors and devices for multiplexeddetection of foodborne pathogen microorganisms", Sensors, 9, pp.5503~5520 (2009)
- Bergveld,P, "A critical evaluation of direct electrical protein detection methods", Biosens. Bioelectron, 6(1), pp.55~72 (1991)
- Hirst, E. R., "Bond-rupture immunosensors-A review", Biosens. Bioelectron, 23(12), pp.1759~1768 (2008)
- A. D’Amico, "Sensors small and numerous:always a winning strategy", Sens. Actuators, B: Chemical, 106(1)통권 : 29, pp.144~152 (2005)
- N. Bojorge Ramirez, "The evolution and developments of immunosensorsfor health and environmental monitoring:problemsand perspectives", Brazilian Journal of ChemicalEngineering, 26(2), pp.227~249 (2009)
- Allen J. Bard, "Electrochemical methods: fundamentals and applications", pp.24~28 (2001), John wiley & Sons
- Allen J. Bard, "Electrochemical methods: fundamentals and applications", pp.156~159 (2001), John wiley & Sons
- J. A. Lee, "An electrochemical impedance biosensor with aptamer-modified pyrolyzed carbon electrode for label-free protein detection", SENSORS AND ACTUATORS B-CHEMICAL, 129(1), pp.372~379 (2008), ELSEVIER SCIENCE SA
- Alan K.H. Cheng, "Design and testing of aptamer-based electrochemicalbiosensors for proteins and small molecules", Bioelectrochemistry, 77(1), pp.1~12 (2009)
- S.-J. Ding, "Electrochemical evaluation of avidin biotin interaction on self-assembled gold electrodes", Electrochimica acta, 50(18), pp.3660~3666 (2005)
- S. Sivasankar, "Direct moleculear level measureemts of the electrostatic properties of a protein surface", Proc. Natl. Acad. Sci. USA, 95, pp.12961~12966 (1998)