MOSFET형 바이오 센서를 이용한 디옥시 니발레놀의 검출
Detection of deoxynivalenol using a MOSFET-based biosensor
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
We have detected deoxynivalenol(DON) using a metal-oxide-semiconductor field-effect-transistor(MOSFET)-based biosensor. The MOSFET-based biosensor is fabricated by a standard complementary metal-oxide-semiconductor(CMOS) process, and the biosensor's electrical characteristics were investigated. The output of the sensor was stabilized by employing a reference electrode that applies a fixed bias to the gate. Au which has a chemical affinity for thiol was used as the gate metal to immobilize a self-assembled monolayer(SAM) made of 16-mercaptohexadecanoic acid(MHDA). The SAM was used to immobilize anti-deoxynivalenol antibody. The carboxyl group of the SAM was bound to the anti- deoxynivalenol antibody. Anti-deoxynivalenol antibody and deoxynivalenol were bound by an antigen-antibody reaction. In this study, it is confirmed that the MOSFET-based biosensor can detect deoxynivalenol at concentrations as low as 0.1 μg/ml. The measurements were performed in phosphate buffered saline(PBS; pH 7.4) solution. To verify the interactionamong the SAM, antibody, and antigen, surface plasmon resonance(SPR) measurements were performed.
Abstract
We have detected deoxynivalenol(DON) using a metal-oxide-semiconductor field-effect-transistor(MOSFET)-based biosensor. The MOSFET-based biosensor is fabricated by a standard complementary metal-oxide-semiconductor(CMOS) process, and the biosensor's electrical characteristics were investigated. The output of the sensor was stabilized by employing a reference electrode that applies a fixed bias to the gate. Au which has a chemical affinity for thiol was used as the gate metal to immobilize a self-assembled monolayer(SAM) made of 16-mercaptohexadecanoic acid(MHDA). The SAM was used to immobilize anti-deoxynivalenol antibody. The carboxyl group of the SAM was bound to the anti- deoxynivalenol antibody. Anti-deoxynivalenol antibody and deoxynivalenol were bound by an antigen-antibody reaction. In this study, it is confirmed that the MOSFET-based biosensor can detect deoxynivalenol at concentrations as low as 0.1 μg/ml. The measurements were performed in phosphate buffered saline(PBS; pH 7.4) solution. To verify the interactionamong the SAM, antibody, and antigen, surface plasmon resonance(SPR) measurements were performed.
참고문헌 (23)
- K.Miller, "Toxicological aspects of food", Elsevier Applied Science, 139~ (1987)
- B. A. Rotter, "Toxicology of deoxynivalenol", J. Toxicol. Environ. Health, 48, pp.1~34 (1996)
- J.J.Pestka, "Enhanced surveillance of foodborne mycotoxins by immunochemical assay", J. Assoc. Off. Anal. Chem, 71, pp.1075~1081 (1988)
- E. Tamiya, "Micro-biosensors for clinical Analysis", Sensors and Actuators, 15, pp.199~207 (1988)
- Y. Hanazato, "Multi-enzyme electrode using hydrogen ion-sensitive field effect transistor", IEEE. Trans. Electron Devices, ED-ee, pp.47~51 (1986)
- S. Caras, "pH-based enzyme potentiometric sensors.part 1-part 3", Anal. Chem, 57, pp.1917~1925 (1985)
- H. Zhu, "Global analysis of protein activities using proteome chip", Science, 293, pp.2101~2105 (2001)
- C. S. Effenhauser, "Integrated capillary electrophoresis on flexible silicone microdevices:Analysis of DNA restriction fragments and detection of single DNA molecules on microchips", Anal. Chem, 72, pp.5731~5735 (1997)
- S. A. Zugel, "Electrophoretically mediated microanalysis of leucine aminopeptidase using two-photon excited fluorescence detection on a microchip", Anal. Chem, 72, pp.5731~5735 (2000)
- J. R. Webster, "Monolithic capillary electrophoresis device with integrated fluorescence detector", Anal. Chem, 73, pp.1622~1626 (2001)
- D. Piscevic, "Surface plasmon microscopy of biotin-streptavidin binding reactions on UV-photopatterned alkanthiol self-assembled monolayers", Supramolecular Science, 2, pp.99~106 (1995)
- J. Wang, "Microseparation chips for performing multienzymatic dehydrogenase", oxidase assays:Simultaneous electrochemicalmeasurement of ethanol and glucose, 2001, pp.73, 1296~1300
- M. A. Schwarz, "A two-electrode configuration for simplified amperometric detection in a microfabricated electrophoretic separation device", Analyst, 126, pp.147~151 (2001)
- C. Yuan, "Energy landscape of streptavidin-biotin complexes measured by atomic force microscopy", Biochemistry, 39, pp.10219~10223 (2000)
- J. Wen, "Microfabricated isoelectric focusing device for direct electrrospray ionization-mass spectrometry", Electrophoresis, 21, pp.191~197 (2000)
- L. Licklider, "A micromachined chip-based electrospray source for mass spectrometry", Anal. Chem, 72, pp.367~375 (2000)
- D.-S. Kim, "An FET-type charge sensor for highly sensitive detection of DNA sequence", Biosens. Bioelectron, 20, pp.69~74 (2004)
- D.-S. Kim, "An extended gate FET-based biosensor integrated with a Si microfluidic channel for detection of protein complexes", Sens. Actuators B, 117, pp.488~494 (2006)
- B. Lim, "Detection of zearalenone using a metal-oxide-semiconductor field-effect-transistor-based biosensor employing a Pt reference electrode", Jpn. J. Appl. Phys, 48(6) (2009)
- J. Homola, "Surface plasmon resonance sensors:review", Sens. Actuators B, 54, pp.3~15 (1999)
- M. Mrksich, "Patterning self-assembled monolayers using microcontact printing:A new technology for biosensors?", Trends Biotechnol, 13, pp.228~ (1995)
- B. Razavi, "Fundamentals of Microelectronics", pp.298~303 (2008), John Wiley & Sons
- P. Estrella, "Label-free sub-picomolar protein detection with field-effect transistors", Analytical Chemistry, 82(9), pp.3531~3536 (2010)