Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The aim of the present study was to evaluate, by means of strain gauge analysis, the effect of different implant angulations on strains around two implants retaining mandibular overdenture with Locator attachments. MATERIALS AND METHODS. Four duplicate mandibular acrylic models were constructed. Two implants were inserted in the canine regions using the following degrees of distal inclinations: group I (control); 0o, group II; 10o, group III; 20o, and group IV; 30o. Locator pink attachments were used to connect the overdenture to the implants and Locator red (designed for severely angled implants) was used for group IV (group IVred). For each group, two linear strain gauges were attached at the mesial and distal surfaces of the acrylic resin around each implant. Peri-implant strain was measured on loading and non-loading sides during bilateral and unilateral loading. RESULTS. For all groups, the mesial surfaces of the implants at loading and non-loading sides experienced compressive (negative) strains, while the distal implant surfaces showed tensile (positive) strains. Group IV showed the highest strain, followed by group III, group II. Both group I and group IVred showed the lowest strain. The strain gauges at the mesial surface of the loading side recorded the highest strain, and the distal surface at non-loading side showed the lowest strain. Unilateral loading recorded significantly higher strain than bilateral loading. CONCLUSION. Peri-implant strains around two implants used to retain mandibular overdentures with Locator attachments increase as distal implant inclination increases, except when red nylon inserts were used. [J Adv Prosthodont 2016;8:116-24]

Abstract

PURPOSE. The aim of the present study was to evaluate, by means of strain gauge analysis, the effect of different implant angulations on strains around two implants retaining mandibular overdenture with Locator attachments. MATERIALS AND METHODS. Four duplicate mandibular acrylic models were constructed. Two implants were inserted in the canine regions using the following degrees of distal inclinations: group I (control); 0o, group II; 10o, group III; 20o, and group IV; 30o. Locator pink attachments were used to connect the overdenture to the implants and Locator red (designed for severely angled implants) was used for group IV (group IVred). For each group, two linear strain gauges were attached at the mesial and distal surfaces of the acrylic resin around each implant. Peri-implant strain was measured on loading and non-loading sides during bilateral and unilateral loading. RESULTS. For all groups, the mesial surfaces of the implants at loading and non-loading sides experienced compressive (negative) strains, while the distal implant surfaces showed tensile (positive) strains. Group IV showed the highest strain, followed by group III, group II. Both group I and group IVred showed the lowest strain. The strain gauges at the mesial surface of the loading side recorded the highest strain, and the distal surface at non-loading side showed the lowest strain. Unilateral loading recorded significantly higher strain than bilateral loading. CONCLUSION. Peri-implant strains around two implants used to retain mandibular overdentures with Locator attachments increase as distal implant inclination increases, except when red nylon inserts were used. [J Adv Prosthodont 2016;8:116-24]

참고문헌 (45)

  1. Mericske-Stern R, "Overdentures: an alternative implant methodology for edentulous patients", Int J Prosthodont, 6, pp.203~208 (1993)
  2. Feine JS, "The McGill Consensus Statement on Overdentures. Montreal, Quebec, Canada. May 24-25, 2002", Int J Prosthodont, 15, pp.413~414 (2002)
  3. Heckmann SM, "Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment", Clin Oral Implants Res, 12, pp.640~647 (2001)
  4. Chikunov I, "Implant-retained partial overdenture with resilient attachments", J Prosthodont, 17, pp.141~148 (2008)
  5. Kleis WK, "A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report", Clin Implant Dent Relat Res, 12, pp.209~218 (2010)
  6. Krennmair G, "Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments:a crossover clinical trial", Int J Oral Maxillofac Implants, 27, pp.1560~1568 (2012)
  7. Moustafa Abdou ELsyad, "Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures", Journal of Prosthodontics, 25(8), pp.656~664 (2015), Wiley-Blackwell[DOI]
  8. Sadig W, "A comparative in vitro study on the retention and stability of implant-supported overdentures", Quintessence Int, 40, pp.313~319 (2009)
  9. Porter JA Jr, "Comparison of load distribution for implant overdenture attachments", Int J Oral Maxillofac Implants, 17, pp.651~662 (2002)
  10. Duyck J, "The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study", Clin Oral Implants Res, 12, pp.207~218 (2001)
  11. Gotfredsen K, "Bone reactions adjacent to titanium implants subjected to static load of different duration. A study in the dog (III)", Clin Oral Implants Res, 12, pp.552~558 (2001)
  12. Geng JP, "Application of finite element analysis in implant dentistry: a review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)
  13. Ogawa T, "Effect of tilted and short distal implants on axial forces and bending moments in implants supporting fixed dental prostheses: an in vitro study", Int J Prosthodont, 23, pp.566~573 (2010)
  14. Krennmair G, "Clinical outcome and prosthodontic compensation of tilted interforaminal implants for mandibular overdentures", Int J Oral Maxillofac Implants, 20, pp.923~929 (2005)
  15. Krekmanov L, "Tilting of posterior mandibular and maxillary implants for improved prosthesis support", Int J Oral Maxillofac Implants, 15, pp.405~414 (2000)
  16. Walton JN, "Implant angulation: a measurement technique, implant overdenture maintenance, and the influence of surgical experience", Int J Prosthodont, 14, pp.523~530 (2001)
  17. Sadowsky SJ, "Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures", Prosthet Dent, 84, pp.327~334 (2000)
  18. Tokuhisa M, "In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability", Int J Prosthodont, 16, pp.128~134 (2003)
  19. Federick DR, "Effects of overdenture retention designs and implant orientations on load transfer characteristics", J Prosthet Dent, 76, pp.624~632 (1996)
  20. Kenney R, "Photoelastic stress patterns produced by implant-retained overdentures", J Prosthet Dent, 80, pp.559~564 (1998)
  21. Ichikawa T, "In vitro study of mandibular implant-retained overdentures: the influence of stud attachments on load transfer to the implant and soft tissue", Int J Prosthodont, 9, pp.394~399 (1996)
  22. Hong HR, "Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.", Int J Oral Maxillofac Implants, 27, pp.e69~e76 (2012)
  23. Celik G, "Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures", J Prosthet Dent, 97, pp.229~235 (2007)
  24. Pigozzo MN, "Photoelastic stress analysis in mandibular bone surrounding bar-clip overdenture implants", Braz Oral Res, 28, pp.S1806~ (2014)
  25. Al-Ghafli SA, "The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system", J Prosthet Dent, 102, pp.140~147 (2009)
  26. Rabbani S, "Investigation of retentive force reduction and wear of the locator attachment system with different implant angulations", Int J Oral Maxillofac Implants, 30, pp.556~563 (2015)
  27. Stephens GJ, "The influence of interimplant divergence on the retention characteristics of locator attachments, a laboratory study", J Prosthodont, 23, pp.467~475 (2014)
  28. Gonda T, "Effect of reinforcement on overdenture strain", J Dent Res, 86, pp.667~671 (2007)
  29. Dong J, "Influence of abutment height on strain in a mandibular overdenture", J Oral Rehabil, 33, pp.594~599 (2006)
  30. el Charkawi HG, "Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis in vitro", J Prosthet Dent, 76, pp.315~320 (1996)
  31. Takeshita S, "Stress analysis of mandibular two-implant overdenture with different attachment systems", Dent Mater J, 30, pp.928~934 (2011)
  32. ELsyad MA, "Effect of different implant positions on strain developed around four implants supporting a mandibular overdenture with rigid telescopic copings", Quintessence Int, 44, pp.679~686 (2013)
  33. Elsyad MA, "The effect of cantilevered bar length on strain around two implants supporting a mandibular overdenture", Int J Oral Maxillofac Implants, 28, pp.e143~e150 (2013)
  34. Uludag B, "Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures", Int J Oral Maxillofac Implants, 29, pp.1053~1057 (2014)
  35. Evtimovska E, "The change in retentive values of locator attachments and hader clips over time", J Prosthodont, 18, pp.479~483 (2009)
  36. Yang TC, "Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forces", Clin Oral Implants Res, 22, pp.1315~1319 (2011)
  37. Gulizio MP, "Effect of implant angulation upon retention of overdenture attachments", J Prosthodont, 14, pp.3~11 (2005)
  38. Koutouzis T, "Bone level changes at axial- and non-axial-positioned implants supporting fixed partial dentures. A 5-year retrospective longitudinal study", Clin Oral Implants Res, 18, pp.585~590 (2007)
  39. Heckmann SM, "Overdenture attachment selection and the loading of implant and denture-bearing area. Part 1: In vivo verification of stereolithographic model", Clin Oral Implants Res, 12, pp.617~623 (2001)
  40. Bevilacqua M, "Three-dimensional finite element analysis of load transmission using different implant inclinations and cantilever lengths", Int J Prosthodont, 21, pp.539~542 (2008)
  41. Watanabe F, "Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution", Odontology, 91, pp.31~36 (2003)
  42. Alsabeeha N, "Attachment systems for mandibular single-implant overdentures: an in vitro retention force investigation on different designs", Int J Prosthodont, 23, pp.160~166 (2010)
  43. Szmukler-Moncler S, "Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature", JBiomed Mater Res, 43, pp.192~203 (1998)
  44. Feingold GM, "The effect of variation of residual ridge angle on partial denture abutment tooth movement", J Oral Rehabil, 15, pp.379~384 (1988)
  45. Akça K, "A comparison of threedimensional finite element stress analysis with in vitro strain gauge measurements on dental implants", Int J Prosthodont, 15, pp.115~121 (2002)

관련 논문AI추천

Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length권긍록, 노관태, 백장현, 유진숙, 이현종대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element studyAngel Alvarez-Arenal, Aritza Brizuela-Velasco, Elena Martin-Fernandez, Hector deLlanos-Lanchares, Ignacio Gonzalez-Gonzalez, Joseba Ellacuria-Echebarria대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses곽재영, 김성균, 손병섭, 이수영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro studyAltug Cilingir, Ergun Bozdag, Hakan Bilhan, Onur Geckili, Selda Arat Bilhan대한구강악안면외과학회 · 대한구강악안면외과학회지2019 · 제45권 제4호Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro studyChikahiro Ohkubo, Jian-Yu Zeng, Jing Zhang, Kentaro Kono, Yasunori Suzuki, Ying Guo대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제1호Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro studyAna Cristina Braga, Antonio Sergio Silva, Carlos Aroso, Esther Berastegui, Jose Manuel Mendes, Raul Ustrell, Tomas Escuin대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제1호

이 간행물의 다른 논문 (11건)