Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.
Abstract
PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.
참고문헌 (55)
- Dantas Ide S, "Success and survival rates of mandibular overdentures supported by two or four implants: a systematic review", Braz Oral Res, 28, pp.74~80 (2014)
- Kern JS, "A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss", Clin Oral Implants Res, 27, pp.174~195 (2016)
- Awad MA, "The effect of mandibular 2-implant overdentures on oral health-related quality of life: an international multicentre study", Clin Oral Implants Res, 25, pp.46~51 (2014)
- Harris D, "A comparison of implant-retained mandibular overdentures and conventional dentures on quality of life in edentulous patients: a randomized, prospective, within-subject controlled clinical trial", Clin Oral Implants Res, 24, pp.96~103 (2013)
- Thomason JM, "The use of mandibular implant-retained overdentures improve patient satisfaction and quality of life", J Evid Based Dent Pract, 12, pp.182~184 (2012)
- Hobkirk JA, Abdel-Latif HH, Howlett J, Welfare R, Moles DR, "Prosthetic treatment time and satisfaction of edentulous patients treated with conventional or implant-stabilized complete mandibular dentures: a case-control study (part 2)", Int J Prosthodont, 22, pp.13~19 (2009)
- Feine JS, "The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002", Int J Oral Maxillofac Implants, 17, pp.601~602 (2002)
- Thomason JM, "Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York Consensus Statement", Br Dent J, 207, pp.185~186 (2009)
- Hong HR, "Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis", Int J Oral Maxillofac Implants, 27, pp.e69~e76 (2012)
- Taylor TD, "Implant Overdentures as the Standard of Care for Edentulous Patients", pp.71~81 (2003), Quintessence
- Elsyad MA, "Expansion of mandibular knifeedge ridge and simultaneous implant placement to retain overdentures: One-year clinical and radiographic results of a prospective study", Clin Implant Dent Relat Res, 19, pp.167~179 (2017)
- Thomason JM, "The use of mandibular implant-retained overdentures improve patient satisfaction and quality of life", J Evid Based Dent Pract, 10, pp.61~63 (2010)
- Ellis JS, "Patient satisfaction with two designs of implant supported removable overdentures;ball attachment and magnets", Clin Oral Implants Res, 20, pp.1293~1298 (2009)
- Gunnar E Carlsson, "Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws", The Journal of Advanced of Prosthodontics, 6(4), pp.245~252 (2014), 대한치과보철학회[DOI]
- Cakarer S, "Complications associated with the ball, bar and Locator attachments for implantsupported overdentures", Med Oral Patol Oral Cir Bucal, 16, pp.e953~e959 (2011)
- Ozan O, "Effect of implant height differences on different attachment types and peri-implant bone in mandibular two-implant overdentures: 3D finite element study", J Oral Implantol, 41, pp.e50~e59 (2015)
- Cristache CM, "Five-year clinical trial using three attachment systems for implant overdentures", Clin Oral Implants Res, 25, pp.e171~e178 (2014)
- Elsyad MA, "Retention and stability of implant-retained mandibular overdentures using different types of resilient attachments: An in vitro study", Int J Oral Maxillofac Implants, 31, pp.1040~1048 (2016)
- Kleis WK, "A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report", Clin Implant Dent Relat Res, 12, pp.209~218 (2010)
- Chung KH, "Retention characteristics of attachment systems for implant overdentures", J Prosthodont, 13, pp.221~226 (2004)
- Uludag B, "Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures", Int J Oral Maxillofac Implants, 29, pp.1053~1057 (2014)
- Daas M, "A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations", Med Eng Phys, 30, pp.218~225 (2008)
- Arat Bilhan S, "The influence of the attachment type and implant number supporting mandibular overdentures on stress distribution: an in vitro study, part I", Implant Dent, 22, pp.39~48 (2013)
- Kuoppala R, "Quality of Life of Patients Treated With Implant-Supported Mandibular Overdentures Evaluated With the Oral Health Impact Profile (OHIP-14): a Survey of 58 Patients", J Oral Maxillofac Res, 4, pp.e4~ (2013)
- Roccuzzo M, "What is the optimal number of implants for removable reconstructions? A systematic review on implant-supported overdentures", Clin Oral Implants Res, 23, pp.229~237 (2012)
- Engelhardt F, "Prosthetic complications and maintenance requirements in locator-attached implant-supported overdentures: A retrospective study", Eur J Prosthodont Restor Dent, 24, pp.31~35 (2016)
- Andreiotelli M, "Prosthodontic complications with implant overdentures: a systematic literature review", Int J Prosthodont, 23, pp.195~203 (2010)
- Liu J, "Influence of implant number on the biomechanical behaviour of mandibular implant-retained", supported overdentures: a three-dimensional finite element analysis, 2013, pp.41, 241~249
- Gross MD, "Occlusion in implant dentistry. A review of the literature of prosthetic determinants and current concepts", Aust Dent J, 53, pp.S60~S68 (2008)
- Kim Y, "Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale", Clin Oral Implants Res, 16, pp.26~35 (2005)
- Mericske-Stern RD, "Management of the edentulous patient", Clin Oral Implants Res, 11, pp.108~125 (2000)
- Petropoulos VC, "Maximum dislodging forces of implant overdenture stud attachments", Int J Oral Maxillofac Implants, 17, pp.526~535 (2002)
- Rutkunas V, "Influence of attachment wear on retention of mandibular overdenture", J Oral Rehabil, 34, pp.41~51 (2007)
- Lekholm U, "Tissue integrated prostheses: osseointegration in clinical dentistry", pp.199~210 (1985), Quintessence
- Rentsch-Kollar A, "Mandibular implant overdentures followed for over 10 years: patient compliance and prosthetic maintenance", Int J Prosthodont, 23, pp.91~98 (2010)
- Dashti MH, "The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis", Quintessence Int, 44, pp.585~590 (2013)
- Kono K, "In vitro assessment of mandibular single", two implant-retained overdentures using stress-breaking attachments, 2014, pp.23, 456~462
- Geng JP, "Application of finite element analysis in implant dentistry: a review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)
- Greco GD, "Biomechanical analysis of the stresses generated by different disocclusion patterns in an implant-supported mandibular complete denture", J Appl Oral Sci, 17, pp.515~520 (2009)
- Baggi L, "The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry:a three-dimensional finite element analysis", J Prosthet Dent, 100, pp.422~431 (2008)
- Chun HJ, "Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments", J Oral Rehabil, 32, pp.193~205 (2005)
- de Almeida EO, "Cortical bone stress distribution in mandibles with different configurations restored with prefabricated barprosthesis protocol: a three-dimensional finite-element analysis", J Prosthodont, 20, pp.29~34 (2011)
- Ebadian B, "Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis", Dent Res J (Isfahan), 9, pp.741~747 (2012)
- Chung KH, "Retentive characteristics of overdenture attachments during repeated dislodging and cyclic loading", Int J Prosthodont, 24, pp.127~129 (2011)
- Stergiou A, "The retentive forces of the locator attachment system at different angulations", Eur J Prosthodont Restor Dent, 20, pp.168~174 (2012)
- Al-Ghafli SA, "The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system", J Prosthet Dent, 102, pp.140~147 (2009)
- Rabbani S, "Investigation of retentive force reduction and wear of the locator attachment system with different implant angulations", Int J Oral Maxillofac Implants, 30, pp.556~563 (2015)
- Barão VA, "Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible-a computed tomography-based three-dimensional finite element analysis", J Biomech, 46, pp.1312~1320 (2013)
- Moustafa Abdou Elsyad, "Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study", The Journal of Advanced of Prosthodontics, 8(2), pp.116~124 (2016), 대한치과보철학회[DOI]
- Jayaraman S, "Threedimensional finite element analysis of immediate loading mini over denture implants with and without acrylonitrile O-ring", Indian J Dent Res, 23, pp.840~841 (2012)
- Tanino F, "Finite element analysis of stress-breaking attachments on maxillary implantretained overdentures", Int J Prosthodont, 20, pp.193~198 (2007)
- Geering AH, "Total-und hybridprothetik" (1986), Thieme Verlag
- Budtz-Jorgensen E, "Diagnosis and treatment" (1999), Quintessence
- Anusavice KJ, "Phillips’ science of dental materials", pp.365~395 (2013), Elsevier
- Petrie CS, "A preliminary three-dimensional finite element analysis of mandibular implant overdentures", Int J Prosthodont, 27, pp.70~72 (2014)