본문 바로가기
KERD
논문KCI 등재

Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS. The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm x 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P <.05), while there was no statistical difference between the normal and resorption group (P >.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P <.05). CONCLUSION. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MIODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.

Abstract

PURPOSE. To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS. The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue on denture base. Two MIs (Φ2.6 mm x 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P <.05), while there was no statistical difference between the normal and resorption group (P >.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P <.05). CONCLUSION. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MIODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.

참고문헌 (40)

  1. Müller F, "Implant-supported mandibular overdentures in very old adults : a randomized controlled trial", J Dent Res, 92, pp.154S~160S (2013)
  2. Ellis JS, "Refusal of implant supported mandibular overdentures by elderly patients", Gerodontology, 28, pp.62~68 (2011)
  3. Marcello-Machado RM, "Mini-implants and narrow diameter implants as mandibular overdenture retainers : a systematic review and meta-analysis of clinical and radiographic outcomes", J Oral Rehabil, 45, pp.161~183 (2018)
  4. Papadimitriou DE, "Narrow-diameter versus standard-diameter implants and their effect on the need for guided bone regeneration : a virtual three-dimensional study", Clin Implant Dent Relat Res, 17, pp.1127~1133 (2015)
  5. Ribeiro AB, "Short-term post-operative pain and discomfort following insertion of mini-implants for retaining mandibular overdentures : a randomized controlled trial", J Oral Rehabil, 42, pp.605~614 (2015)
  6. Jawad S, "A pilot randomised controlled trial evaluating mini and conventional implant retained dentures on the function and quality of life of patients with an edentulous mandible", BMC Oral Health, 17, pp.53~ (2017)
  7. Petrie CS, "Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis", Clin Oral Implants Res, 16, pp.486~494 (2005)
  8. Monje A, "The critical peri-implant buccal bone wall thickness revisited : an experimental study in the beagle dog", Int J Oral Maxillofac Implants, 34, pp.1328~1336 (2019)
  9. Feine JS, "The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients", Gerodontology, 19, pp.3~4 (2002)
  10. Thomason JM, "Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York Consensus Statement", Br Dent J, 207, pp.185~186 (2009)
  11. Preoteasa E, "A 3-year follow-up study of overdentures retained by mini-dental implants", Int J Oral Maxillofac Implants, 29, pp.1170~1176 (2014)
  12. Kanazawa M, "Clinical guidelines and procedures for provision of mandibular overdentures on 4 mini-dental implants", J Prosthet Dent, 117, pp.22~27 (2017)
  13. Aunmeungtong W, "Comparative clinical study of conventional dental implants and mini dental implants for mandibular overdentures: a randomized clinical trial", Clin Implant Dent Relat Res, 19, pp.328~340 (2017)
  14. Morneburg TR, "Success rates of microimplants in edentulous patients with residual ridge resorption", Int J Oral Maxillofac Implants, 23, pp.270~276 (2008)
  15. Albrektsson T, "The long-term efficacy of currently used dental implants : a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
  16. Qian J, "Reasons for marginal bone loss around oral implants", Clin Implant Dent Relat Res, 14, pp.792~807 (2012)
  17. Papaspyridakos P, "Success criteria in implant dentistry : a systematic review", J Dent Res, 91, pp.242~248 (2012)
  18. Saaby M, "Factors influencing severity of peri-implantitis", Clin Oral Implants Res, 27, pp.7~12 (2016)
  19. Spies BC, "Does oral implant design affect marginal bone loss? Results of a parallel-group randomized controlled equivalence trial", Biomed Res Int, 2018, pp.8436437~ (2018)
  20. Mundt T, "Changes in bone levels around mini-implants in edentulous arches", Int J Oral Maxillofac Implants, 30, pp.1149~1155 (2015)
  21. Ozgur GO, "Risk factors associated with implant marginal bone loss : a retrospective 6-year follow-up study", Implant Dent, 25, pp.122~127 (2016)
  22. Saravi BE, "Marginal bone loss around oral implants supporting fixed versus removable prostheses : a systematic review", Int J Implant Dent, 6, pp.20~ (2020)
  23. Jawad S, "Survival of mini dental implants used to retain mandibular complete overdentures : systematic review", Int J Oral Maxillofac Implants, 34, pp.343~356 (2019)
  24. Galindo-Moreno P, "Marginal bone loss as success criterion in implant dentistry : beyond 2 mm", Clin Oral Implants Res, 26, pp.e28~e34 (2015)
  25. Linetskiy I, "Impact of annual bone loss and different bone quality on dental implant success-a finite element study", Comput Biol Med, 91, pp.318~325 (2017)
  26. Leitão-Almeida B, "Effect of crown to implant ratio and implantoplasty on the fracture resistance of narrow dental implants with marginal bone loss : an in vitro study", BMC Oral Health, 20, pp.329~ (2020)
  27. Isidor F, "Influence of forces on peri-implant bone", Clin Oral Implants Res, 17, pp.8~18 (2006)
  28. Oh TJ, "The causes of early implant bone loss : myth or science", J Periodontol, 73, pp.322~333 (2002)
  29. Reilly DT, "The elastic and ultimate properties of compact bone tissue", J Biomech, 8, pp.393~405 (1975)
  30. Yoon KH, "3D finite element analysis of changes in stress levels and distributions for an osseointegrated implant after vertical bone loss", Implant Dent, 20, pp.354~359 (2011)
  31. Romeed SA, "Marginal bone loss influence on the biomechanics of single implant crowns", J Craniofac Surg, 24, pp.1459~1465 (2013)
  32. Unsal GS, "Evaluation of stress distribution on mandibular implant-supported overdentures with different bone heights and attachment types : a 3D finite element analysis", J Oral Implantol, 45, pp.363~370 (2019)
  33. Kono K, "In vitro assessment of mandibular single", two implant-retained overdentures using stress-breaking attachments, 2014, pp.23, 456~462
  34. Sato H, "Oral mucosa pressure caused by mandibular implant overdenture with different types of attachments", J Prosthodont Res, 64, pp.145~151 (2020)
  35. 임한울, "A study on the changes in attractive force of magnetic attachments for overdenture", The Journal of Advanced of Prosthodontics, 8(1), pp.9~15 (2016), 대한치과보철학회[DOI]
  36. 이은지, "The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture", The Journal of Advanced of Prosthodontics, 9(1), pp.14~21 (2017), 대한치과보철학회[DOI]
  37. Takeshita S, "Stress analysis of mandibular two-implant overdenture with different attachment systems", Dent Mater J, 30, pp.928~934 (2011)
  38. Takahashi T, "Effect of attachment type on implant strain in maxillary implant overdentures: Comparison of ball, locator, and magnet attachments. Part 2: Palateless dentures", Int J Oral Maxillofac Implants, 33, pp.357~364 (2018)
  39. Patil PG, "Biomechanical behavior of mandibular overdenture retained by two standard implants or 2 mini implants : A 3-dimensional finite element analysis", J Prosthet Dent, 125, pp.138~138.e1-8 (2021)
  40. Shahmiri R, "Strain distribution in a Kennedy Class I implant assisted removable partial denture under various loading conditions", Int J Dent, 2013, pp.351279~ (2013)

관련 논문AI추천

Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length권긍록, 노관태, 백장현, 유진숙, 이현종대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro studyAltug Cilingir, Ergun Bozdag, Hakan Bilhan, Onur Geckili, Selda Arat Bilhan대한구강악안면외과학회 · 대한구강악안면외과학회지2019 · 제45권 제4호The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture신수연, 이은지대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제1호Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element studyNurullah Turker, Ulviye Sebnem Buyukkaplan대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제6호Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element studyAngel Alvarez-Arenal, Aritza Brizuela-Velasco, Elena Martin-Fernandez, Hector deLlanos-Lanchares, Ignacio Gonzalez-Gonzalez, Joseba Ellacuria-Echebarria대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro studyAhmed Samir Khirallah, Fathi Abo Setta, Moustafa Abdou Elsyad대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제2호

이 간행물의 다른 논문 (6건)