Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

PURPOSE. The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. MATERIALS AND METHODS. Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured. RESULTS. Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force. CONCLUSION. To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

Abstract

PURPOSE. The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. MATERIALS AND METHODS. Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured. RESULTS. Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force. CONCLUSION. To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

참고문헌 (22)

  1. Doundoulakis JH, "The implant-supported overdenture as an alternative to the complete mandibular denture", J Am Dent Assoc, 134, pp.1455~1458 (2003)
  2. Feine JS, "The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients", Gerodontology, 19, pp.3~4 (2002)
  3. Burns DR, "Mandibular implant overdenture treatment: consensus and controversy", J Prosthodont, 9, pp.37~46 (2000)
  4. Jemt T, "In vivo load measurements on osseointegrated implants supporting fixed or removable prostheses: a comparative pilot study", Int J Oral Maxillofac Implants, 6, pp.413~417 (1991)
  5. Naert I, "Overdentures supported by osseointegrated fixtures for the edentulous mandible: a 2.5-year report", Int J Oral Maxillofac Implants, 3, pp.191~196 (1988)
  6. Mericske-Stern R, "Threedimensional force measurements on mandibular implants supporting overdentures", Int J Oral Maxillofac Implants, 7, pp.185~194 (1992)
  7. Setz J, "Complete dentures fixed on dental implants: chewing patterns and implant stress", Int J Oral Maxillofac Implants, 4, pp.107~111 (1989)
  8. Rangert B, "Forces and moments on Branemark implants", Int J Oral Maxillofac Implants, 4, pp.241~247 (1989)
  9. Tokuhisa M, "In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability", Int J Prosthodont, 16, pp.128~134 (2003)
  10. el-Sheikh AM, "Force transmission in bar-retained implant-stabilised mandibular over-dentures: an in-vitro study", Eur J Prosthodont Restor Dent, 10, pp.173~178 (2002)
  11. Porter JA Jr, "Comparison of load distribution for implant overdenture attachments", Int J Oral Maxillofac Implants, 17, pp.651~662 (2002)
  12. Heckmann SM, "Overdenture attachment selection and the loading of implant and denture-bearing area. Part 1: In vivo verification of stereolithographic model", Clin Oral Implants Res, 12, pp.617~623 (2001)
  13. Meijer HJ, "Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible", J Prosthet Dent, 68, pp.96~102 (1992)
  14. Rosa LB, "Bite force and masticatory efficiency in individuals with different oral rehabilitations", Open J Stomatol, 2, pp.21~26 (2012)
  15. Federick DR, "Effects of overdenture retention designs and implant orientations on load transfer characteristics", J Prosthet Dent, 76, pp.624~632 (1996)
  16. Menicucci G, "Mandibular implant-retained overdenture: finite element analysis of two anchorage systems", Int J Oral Maxillofac Implants, 13, pp.369~376 (1998)
  17. Meijer HJ, "A three-dimensional, finite-element analysis of bone around dental implants in an edentulous human mandible", Arch Oral Biol, 38, pp.491~496 (1993)
  18. Meijer HJ, "A three-dimensional finite element study on two versus four implants in an edentulous mandible", Int J Prosthodont, 7, pp.271~279 (1994)
  19. Menicucci G, "Mandibular implant-retained overdenture: a clinical trial of two anchorage systems", Int J Oral Maxillofac Implants, 13, pp.851~856 (1998)
  20. Duyck J, "In vivo forces on oral implants supporting a mandibular overdenture: the influence of attachment system", Clin Oral Investig, 3, pp.201~207 (1999)
  21. Sadowsky SJ, "Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures", J Prosthet Dent, 84, pp.327~334 (2000)
  22. Trakas T, "Attachment systems for implant retained overdentures: a literature review", Implant Dent, 15, pp.24~34 (2006)

관련 논문AI추천

Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element studyAngel Alvarez-Arenal, Aritza Brizuela-Velasco, Elena Martin-Fernandez, Hector deLlanos-Lanchares, Ignacio Gonzalez-Gonzalez, Joseba Ellacuria-Echebarria대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro studyAhmed Samir Khirallah, Fathi Abo Setta, Moustafa Abdou Elsyad대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제2호Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysisMostafa Omran Hussein대한치과보철학회 · The Journal of Advanced of Prosthodontics2013 · 제5권 제3호Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage김민정, 홍성옥대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제2호Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element studyNurullah Turker, Ulviye Sebnem Buyukkaplan대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제6호Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro studyAltug Cilingir, Ergun Bozdag, Hakan Bilhan, Onur Geckili, Selda Arat Bilhan대한구강악안면외과학회 · 대한구강악안면외과학회지2019 · 제45권 제4호

이 간행물의 다른 논문 (13건)