Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: Clix®, Dalbo-Plus® and Locator®. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37°C. The abutments were placed at angulations of 0°, 10° and 20°. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F (2.48) = 343619, P<.05) and the type of attachment (F (7.48) = 23.220, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

Abstract

PURPOSE. This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: Clix®, Dalbo-Plus® and Locator®. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37°C. The abutments were placed at angulations of 0°, 10° and 20°. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F (2.48) = 343619, P<.05) and the type of attachment (F (7.48) = 23.220, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

참고문헌 (33)

  1. Feine JS, "The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002", Int J Oral Maxillofac Implants, 17, pp.601~602 (2002)
  2. British Society for the Study of Prosthetic Dentistry, "The York consensus statement on implant-supported overdentures", Eur J Prosthodont Restor Dent, 17, pp.164~165 (2009)
  3. Tallgren A, "The continuing reduction of the residual alveolar ridges in complete denture wearers: a mixed-longitudinal study covering 25 years", J Prosthet Dent, 89, pp.427~435 (2003)
  4. de Jong MH, "Posterior mandibular residual ridge resorption in patients with overdentures supported by two or four endosseous implants in a 10-year prospective comparative study", Int J Oral Maxillofac Implants, 25, pp.1168~1174 (2010)
  5. Kobayashi M, "Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems", Clin Oral Implants Res, 25, pp.426~434 (2014)
  6. Tabatabaian F, "The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supportedoverdentures", J Dent (Tehran), 11, pp.506~515 (2014)
  7. Antonio Sergio Silva, "The influence of saliva pH value on the retention and durability of barclip attachments", The Journal of Advanced of Prosthodontics, 7(1), pp.32~38 (2015), 대한치과보철학회[DOI]
  8. Faul F, "G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences", Behav Res Methods, 39, pp.175~191 (2007)
  9. Branchi R, "Resistance to wear of four matrices with ball attachments for implant overdentures:a fatigue study", J Prosthodont, 19, pp.614~619 (2010)
  10. Botega DM, "Retention force and fatigue strength of overdenture attachment systems", J Oral Rehabil, 31, pp.884~889 (2004)
  11. Queiroz GM, "Electrochemical behavior and pH stability of artificial salivas for corrosion tests", Braz Oral Res, 21, pp.209~215 (2007)
  12. Stüttgen U, "Effect of saliva smears in experimental wear studies on precious and non-precious metal casting alloys", Zahntechnik (Zur), 43, pp.466~468 (1985)
  13. Caldwell RC, "Adhesion of foods to teeth", J Dent Res, 41, pp.821~832 (1962)
  14. Setz I, "Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study", J Prosthet Dent, 80, pp.323~329 (1998)
  15. Walmsley AD, "Magnetic retention in prosthetic dentistry", Dent Update, 29, pp.428~433 (2002)
  16. Walmsley AD, "Implant supported overdenturesthe Birmingham experience", J Dent, 25, pp.S43~S47 (1997)
  17. Cohen BI, "Comparative study of two precision overdenture attachment designs", J Prosthet Dent, 76, pp.145~152 (1996)
  18. Trakas T, "Attachment systems for implant retained overdentures: a literature review", Implant Dent, 15, pp.24~34 (2006)
  19. Ortegón SM, "Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures:an in vitro study", J Prosthet Dent, 101, pp.231~238 (2009)
  20. Bayer S, "Comparative study of four retentive anchor systems for implant supported overdentures-retention force changes", Gerodontology, 26, pp.268~272 (2009)
  21. Fakhry A, "Methodology for measuring the in vitro seating and unseating forces of prefabricated attachment systems used to retain implant overdentures", J Prosthodont, 19, pp.87~94 (2010)
  22. Rutkunas V, "Wear simulation effects on overdenture stud attachments", Dent Mater J, 30, pp.845~853 (2011)
  23. Chen IC, "Freedom of rotation of selected overdenture attachments: an in vitro study", J Prosthet Dent, 106, pp.78~86 (2011)
  24. Al-Ghafli SA, "The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system", J Prosthet Dent, 102, pp.140~147 (2009)
  25. Kleis WK, "A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report", Clin Implant Dent Relat Res, 12, pp.209~218 (2010)
  26. Alsabeeha N, "Attachment systems for mandibular single-implant overdentures: an in vitro retention force investigation on different designs", Int J Prosthodont, 23, pp.160~166 (2010)
  27. Lehmann KM, "Studies on the retention capability of push-button attachments", SSO Schweiz Monatsschr Zahnheilkd, 86, pp.521~530 (1976)
  28. Petropoulos VC, "Comparison of retention and strain energies of stud attachments for implant overdentures", J Prosthodont, 20, pp.286~293 (2011)
  29. Petropoulos VC, "Current concepts and techniques in complete denture final impression procedures", J Prosthodont, 12, pp.280~287 (2003)
  30. Petropoulos VC, "Maximum dislodging forces of implant overdenture stud attachments", Int J Oral Maxillofac Implants, 17, pp.526~535 (2002)
  31. Petropoulos VC, "Comparison of retention and release periods for implant overdenture attachments", Int J Oral Maxillofac Implants, 12, pp.176~185 (1997)
  32. Uludag B, "Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures", Int J Oral Maxillofac Implants, 29, pp.1053~1057 (2014)
  33. Türk PE, "In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures", Int J Oral Maxillofac Implants, 29, pp.1106~1113 (2014)

관련 논문AI추천

Comparison of changes in retentive force of three stud attachments for implant overdentures김수민, 윤미정, 이소현, 전영찬, 정창모, 최재원, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제4호Performance of attachments used in implantsupported overdentures: review of trends in the literatureDamian J. Lee대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제1호Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro studyAhmed Samir Khirallah, Fathi Abo Setta, Moustafa Abdou Elsyad대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제2호Effects of type of magnet attachment and implant angulation in two implant overdenture models강경환, 송소연, 신상완, 이정열대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제1호Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length권긍록, 노관태, 백장현, 유진숙, 이현종대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar배강호, 배은빈, 배지현, 조원탁, 채성기, 최재원, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제1호

이 간행물의 다른 논문 (9건)