Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective: This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC). Methods: The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width. The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C. Results: The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency. Conclusions: Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
Abstract
Objective: This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC). Methods: The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width. The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C. Results: The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency. Conclusions: Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
참고문헌 (27)
- Meade MJ, "A survey of orthodontic clear aligner practices among orthodontists", Am J Orthod Dentofacial Orthop, 162, pp.e302~e311 (2022)[DOI]
- Galan-Lopez L, "A systematic review of the accuracy and efficiency of dental movements with Invisalign®", Korean J Orthod, 49, pp.140~149 (2019)[DOI]
- Rossini G, "Efficacy of clear aligners in controlling orthodontic tooth movement : a systematic review", Angle Orthod, 85, pp.881~889 (2015)[DOI]
- Haouili N, "Has Invisalign improved? A prospective follow-up study on the efficacy of tooth movement with Invisalign", Am J Orthod Dentofacial Orthop, 158, pp.420~425 (2020)[DOI]
- Meng X, "Effects of different designs of orthodontic clear aligners on the maxillary central incisors in the tooth extraction cases : a biomechanical study", BMC Oral Health, 23, pp.416~ (2023)[DOI]
- Cheng Y, "The three-dimensional displacement tendency of teeth depending on incisor torque compensation with clear aligners of different thicknesses in cases of extraction : a finite element study", BMC Oral Health, 22, pp.499~ (2022)[DOI]
- Grant J, "Forces and moments generated by 3D direct printed clear aligners of varying labial and lingual thicknesses during lingual movement of maxillary central incisor : an in vitro study", Prog Orthod, 24, pp.23~ (2023)[DOI]
- Jiang T, "Clear aligners for maxillary anterior en masse retraction : a 3D finite element study", Sci Rep, 10, pp.10156~ (2020)[DOI]
- Cai Y, "Finite element method analysis of the periodontal ligament in mandibular canine movement with transparent tooth correction treatment", BMC Oral Health, 15, pp.106~ (2015)[DOI]
- Yokoi Y, "Effects of attachment of plastic aligner in closing of diastema of maxillary dentition by finite element method", J Healthc Eng, 2019, pp.1075097~ (2019)[DOI]
- Johal A, "The reliability of thermoform retainers : a laboratory-based comparative study", Eur J Orthod, 37, pp.503~507 (2015)[DOI]
- Min S, "The effect of thickness and deflection of orthodontic thermoplastic materials on its mechanical properties", Korean J Orthod, 40, pp.16~26 (2010)[DOI]
- Ryokawa H, "The mechanical properties of dental thermoplastic materials in a simulated intraoral environment", Orthod Waves, 65, pp.64~72 (2006)[DOI]
- Lee SY, "Thermo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners", Sci Rep, 12, pp.6246~ (2022)[DOI]
- Tartaglia GM, "Direct 3D printing of clear orthodontic aligners : current state and future possibilities", Materials(Basel), 14, pp.1799~ (2021)[DOI]
- Savignano R, "Biomechanical effects of different auxiliary-aligner designs for the extrusion of an upper central incisor : a finite element analysis", J Healthc Eng, 2019, pp.9687127~ (2019)[DOI]
- Kassas W, "Assessment of Invisalign treatment outcomes using the ABO model grading system", J World Fed of Orthod, 2, pp.e61~e64 (2013)[DOI]
- 2.0.co;2,
- Rossini G, "Incisors extrusion with clear aligners technique : a finite element analysis study", Appl Sci, 11, pp.1167~ (2021)[DOI]
- Karras T, "Efficacy of Invisalign attachments : a retrospective study", Am J Orthod Dentofacial Orthop, 160, pp.250~258 (2021)[DOI]
- Kim WH, "Optimal position of attachment for removable thermoplastic aligner on the lower canine using finite element analysis", Materials(Basel), 13, pp.3369~ (2020)[DOI]
- Yao S, "Improvements of tooth movement efficiency and torque control in expanding the arch with clear aligners : a finite element analysis", Front Bioeng Biotechnol, 11, pp.1120535~ (2023)[DOI]
- Elkholy F, "Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation", J Orofac Orthop, 76, pp.460~475 (2015)[DOI]
- Wheeler TT, "Orthodontic clear aligner treatment", Semin Orthod, 23, pp.83~89 (2017)[DOI]
- Phan X, "Clinical limitations of Invisalign", J Can Dent Assoc, 73, pp.263~266 (2007)
- Seo JH, "Comparative analysis of stress in the periodontal ligament and center of rotation in the tooth after orthodontic treatment depending on clear aligner thickness-finite element analysis study", Materials(Basel), 14, pp.324~ (2021)[DOI]
- McKay A, "Forces and moments generated during extrusion of a maxillary central incisor with clear aligners : an in vitro study", BMC Oral Health, 23, pp.495~ (2023)[DOI]
