본문 바로가기
KERD
논문KCI 등재

Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation

5

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC- 85 clear aligners (CAs), with various margin designs, during premolar rotation. Methods: In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins. Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes. Results: The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles. Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners. Conclusions: Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Abstract

Objective: To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC- 85 clear aligners (CAs), with various margin designs, during premolar rotation. Methods: In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins. Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes. Results: The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles. Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners. Conclusions: Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

관련 논문AI추천

Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation methodJong-Chan Baik, Ki Beom Kim, Seong-Sik Kim, Soo-Byung Park, Sung-Hun Kim, Yonghun Cho, Yong-Il Kim, Youn-Kyung Choi, Yunju Baek대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제6호Pattern of change in force and moment according to amounts of labial tipping and material types of clear aligner: In vitro experiment with a six-axis mechanical sensor apparatusIl-Hyung Yang, Keun-Chul Cho, Ki Beom Kim, Michael Lee, Seung-Hak Baek대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제4호Accuracy of orthodontic movements with 3D printed aligners: A prospective observational pilot studyAlessandra Campobasso, Anna De Mari, Filippo Forin Valvecchi, Giorgio Gastaldi, Giovanni Battista, Marco Migliorati, Paolo Pesce, Sara Drago, Tommaso Castroflorio대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제3호Force changes associated with differential activation of en-masse retraction and/or intrusion with clear alignersShuo Li, Wei Hu, Ye Zhu대한치과교정학회 · 대한치과교정학회지2021 · 제51권 제1호Comparative mechanical performance of thermoplastic materials for clear aligners under simulated oral conditionsCe Bian, Jingyao Sun, Miao Liu, Ning Zhang, Xuan Qin, Yajie Wang, Yang Han, Yuxing Bai대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제5호Iterative finite element analysis of clear aligner-induced bodily canine movement under alveolar bone loss conditionsKiyean Kim, Seong-Sik Kim, Seung Eun Baek, Sung-Hun Kim, Yong-Il Kim, Youn-Kyung Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제6호

이 간행물의 다른 논문 (8건)