본문 바로가기
KERD
논문KCI 등재

Evaluation of the effect of attachments on torque control of palatally positioned maxillary lateral teeth with clear aligners: Finite element analysis

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis. Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mmthick aligners and horizontal attachments, were integrated into the software. Six distinct simulations were generated: (1) attachment-free, (2) labial attachment placed gingivally, (3) labial attachment placed mid-crown, (4) labial attachment placed incisally, (5) palatal attachment, and (6) attachment placed labially and palatally. The evaluation was performed using a default aligner activation of 0.25 mm. Results: The crown of the lateral incisor demonstrated labial movement, while the root exhibited palatal movement in all models. Group 6 showed the lowest crown and root displacements on both axes, whereas the attachmentfree group exhibited the greatest crown movement. The aligner experienced maximum deformation at the incisal edge, with deformation progressively decreasing towards the gingival region. Group 6 demonstrated the least deformation of all groups. The Von Mises stresses in the periodontal ligament (PDL) were most pronounced at the gingival level, with higher values on the palatal side than on the labial side. Conclusions: The use of attachments, particularly the combination of labial and palatal attachments, enables a more precise labialization process, helping to reduce tipping. Increasing crown movement of the lateral incisor elevates stress within the PDL, with the highest stress observed in the palatal region at the gingival level.

Abstract

Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis. Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mmthick aligners and horizontal attachments, were integrated into the software. Six distinct simulations were generated: (1) attachment-free, (2) labial attachment placed gingivally, (3) labial attachment placed mid-crown, (4) labial attachment placed incisally, (5) palatal attachment, and (6) attachment placed labially and palatally. The evaluation was performed using a default aligner activation of 0.25 mm. Results: The crown of the lateral incisor demonstrated labial movement, while the root exhibited palatal movement in all models. Group 6 showed the lowest crown and root displacements on both axes, whereas the attachmentfree group exhibited the greatest crown movement. The aligner experienced maximum deformation at the incisal edge, with deformation progressively decreasing towards the gingival region. Group 6 demonstrated the least deformation of all groups. The Von Mises stresses in the periodontal ligament (PDL) were most pronounced at the gingival level, with higher values on the palatal side than on the labial side. Conclusions: The use of attachments, particularly the combination of labial and palatal attachments, enables a more precise labialization process, helping to reduce tipping. Increasing crown movement of the lateral incisor elevates stress within the PDL, with the highest stress observed in the palatal region at the gingival level.

관련 논문AI추천

Evaluation of the effects of the third molar on distalization and the effects of attachments on distalization and expansion with clear aligners: Three-dimensional finite element studyAslihan Kuguoglu, Bengisu Akarsu-Guven대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제1호Iterative finite element analysis of clear aligner-induced bodily canine movement under alveolar bone loss conditionsKiyean Kim, Seong-Sik Kim, Seung Eun Baek, Sung-Hun Kim, Yong-Il Kim, Youn-Kyung Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제6호Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study김용일, Choi Youn-Kyung, Kim Ki Beom, Kim Sung-Hun, Ko Ching-Chang, Oh Sewoong대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제6호Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation methodJong-Chan Baik, Ki Beom Kim, Seong-Sik Kim, Soo-Byung Park, Sung-Hun Kim, Yonghun Cho, Yong-Il Kim, Youn-Kyung Choi, Yunju Baek대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제6호Pattern of change in force and moment according to amounts of labial tipping and material types of clear aligner: In vitro experiment with a six-axis mechanical sensor apparatusIl-Hyung Yang, Keun-Chul Cho, Ki Beom Kim, Michael Lee, Seung-Hak Baek대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제4호En masse maxillary dentition distalization with clear aligners using infrazygomatic mini-implants: A finite element studyAllahyar Geramy, Joseph Bouserhal, Lina Medawar, Nayla Bassil Nassif, Nicolas Nassar, Patrick Sayegh, Roland Kmeid대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호

이 간행물의 다른 논문 (7건)