두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향

Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

Abstract

This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

참고문헌 (18)

  1. Joyce KE, "A genetic algorithm for controlling an agent-based model of the functional human brain", Biomed Sci Instrum, 48, pp.210~217 (2012)
  2. Khotanlou H, "Segmentation of Multiple Sclerosis Lesions in Brain MR Images Using Spatially Constrained Possibilistic Fuzzy C-Means Classification", J Med Signals Sens, 1, pp.149~155 (2011)
  3. Kim HJ, "Radiologic Findings of Acute Spontaneous Subdural Hematomas", The Journal of the Korean Radiological Society, 38(3), pp.391~396 (1988)
  4. 이상목, "자발성 소뇌출혈의 임상 양상 및 예후: 치료 방법의 결정", 대한신경과학회지, 22(4), pp.290~294 (2004), 대한신경과학회
  5. Lee YB, "Skull Fracture and Traumaric Intracranial Lesions", Dong-guk Medicine, 4, pp.63~70 (1977)
  6. Lee JK, "Evaluation of maxillary sinuses and adjacent tissues on panoramic photographs according to head position", The American Academy of Oral and Maxillofacial Radiology, 22(2), pp.315~327 (1992)
  7. Ballinger PW, "MERRILL’S ATLAS OF RADIOGRAPHIC POSITIONS and RADIOLOGIC PROCEDURES", pp.12~ (1955), Mosby-Year Book
  8. 신정섭, "종합병원 영상의학과의 감염관리 대한 분석", 한국방사선학회논문지, 6(5), pp.335~341 (2012), 한국방사선학회[DOI]
  9. "7th Human Body Index Report" (2015)[URL]
  10. 김종석, "흉부 전・후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향", 방사선기술과학, 44(4), pp.295~300 (2021), 대한방사선과학회
  11. 김정민, "CR X선 영상의 복합잡음 감소에 관한 연구", 방사선기술과학, 30(1), pp.1~6 (2007), 대한방사선과학회
  12. Ann KH, "Medical-related infection control of diagnostic radiation generator using silver nano antibacterial material", master, pp.2019
  13. Department of Health and Human Services, "Guidelines", ~ (2005)
  14. Kim YH, "Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography", Journal of Korean Society of Radiological Technology, 21(1), pp.52~58 (1988)
  15. 주영철, "늑골 방사선검사 시 X선관 초점-영상수신체간 거리에 따른 환자선량과 화질의 연관성 평가", 방사선기술과학, 41(5), pp.391~396 (2018), 대한방사선과학회[DOI]
  16. Park YS, "An Experiment on Scattered-ray Content Ratio and Skin Dose according to the Exposure Condition for Chest Radiography", Journal of Korean Society of Radiological Technology, 15(2), pp.3~9 (1992)
  17. Park YW, "A study on the proper examination distance of a digital X-ray imaging device for diagnosis", master, pp.2014
  18. 권순무, "Digital Chest Radiography에서 방사선량에 대한Source to Image-Receptor Distance (SID)의 영향", 한국방사선학회논문지, 8(4), pp.203~210 (2014), 한국방사선학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (7건)