늑골 방사선검사 시 X선관 초점-영상수신체간 거리에 따른 환자선량과 화질의 연관성 평가
Evaluation of Relationship between Radiation Dose and Image Quality according to Source to Image Receptor Distance in Rib Series Radiography
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
The purpose of this study was to compare and analyze the patient dose according to the distance between the X-ray tube focus and the image receptor, and to propose a new method for quantitatively evaluating the image quality. Using this quantitative evaluation method, the optimal distance for increasing x-ray image quality with low radiation dose was estimated between source and image receptor in Rib series radiography. Phantom images were obtained by changing the distance between focus and image receptor (100 ㎝ and 180 ㎝). The patient radiation dose was estimated using entrance surface dose and dose area product. In order to evaluate image quality objectively, a non - reference image evaluation method was employed with paper and salt noise and Gaussian filter. As a result of this study, when the SID was changed from 100 ㎝ to 180 ㎝, the entrance surface dose decreased by 4 ~ 5 times and the dose area product decreased by 3 times. In addition, there is no significant difference in image quality between of SID 180 cm and SID 100 cm. In conclusion, it was demonstrated that performing the rib series radiography at SID 180 cm is an optimal method to reduce the exposure dose and improve the image quality.
Abstract
The purpose of this study was to compare and analyze the patient dose according to the distance between the X-ray tube focus and the image receptor, and to propose a new method for quantitatively evaluating the image quality. Using this quantitative evaluation method, the optimal distance for increasing x-ray image quality with low radiation dose was estimated between source and image receptor in Rib series radiography. Phantom images were obtained by changing the distance between focus and image receptor (100 ㎝ and 180 ㎝). The patient radiation dose was estimated using entrance surface dose and dose area product. In order to evaluate image quality objectively, a non - reference image evaluation method was employed with paper and salt noise and Gaussian filter. As a result of this study, when the SID was changed from 100 ㎝ to 180 ㎝, the entrance surface dose decreased by 4 ~ 5 times and the dose area product decreased by 3 times. In addition, there is no significant difference in image quality between of SID 180 cm and SID 100 cm. In conclusion, it was demonstrated that performing the rib series radiography at SID 180 cm is an optimal method to reduce the exposure dose and improve the image quality.
참고문헌 (15)
- Gabram SG, "Clinical management of blunt trauma patients unilateral rib fractures: a randomized trial", World J Surg, 19, pp.388~393 (1995)
- Buger EM, "Rib fractures in the eldely", J Trauma, 48, pp.1040~1047 (2000)
- Baker SP, "The injury severity score: a method for describing patients with multiple injuries and evaluating emergency care", J Trauma, 14, pp.187~196 (1974)
- 김한용, "늑골골절 환자 치료: 결과에 영향을 주는 위험인자 분석", Journal of Chest Surgery, 43(3), pp.285~291 (2010), 대한심장혈관흉부외과학회
- Martensen KM, "Rdiographic Image Analysis" (2011), EKSEVIER
- The Korean Society of Medical Imaging Technology, "TEXTBOOK of Radiographic Positioning and Clinical Diagnosis" (2008), CHUNG-GU
- Kim HS, "Radiographic Imaging" (2008), Daihaks
- Hoffstetter P, "Clinical Significance of Conventional Rib Series in Patients with Minor Thoracic Trauma", Forstschr RRntgenstr, 186, pp.876~880 (2014)
- Park JB, "Diagnostic accuracy of the inverted grayscale rib series for detection of rib fracture in minor chest trauma", American Journal of Emergency Medicine, 33, pp.548~552 (2015)
- Poole GV, "Morbidity and mortality rates in major blunt trauma to the upper chest", Ann Surg, 193, pp.70~75 (1981)
- Harris GJ, "Pediatric first rib fractures", J Trauma, 30, pp.343~345 (1990)
- 박하영, "급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사 : 예비 연구", 방사선기술과학, 39(4), pp.543~547 (2016), 대한방사선과학회[DOI]
- 편도영, "특이값 분해 기반 Dynamic PET 영상의 노이즈 제거 기법 : 예비 연구", 방사선기술과학, 39(2), pp.227~236 (2016), 대한방사선과학회[DOI]
- Mittal A, "No-Reference Image Quality Assessment in the Spatial Domain", IEEE Transactions on Image Processing, 21(12), pp.4695~4708 (2012)
- Mittal A, "Referenceless Image Spatial Quality Evaluation Engine", Presentation at the 45th Asilomar Conference on Signals, Systems and Computers (2011)