본문 바로가기
KERD
논문KCI 등재

머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구

A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town’s examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37∘ in the cathode direction and 30∘ and 37∘ in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30∘ and 37∘ The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

Abstract

The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town’s examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37∘ in the cathode direction and 30∘ and 37∘ in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30∘ and 37∘ The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

참고문헌 (16)

  1. 황수련, "일차 의료기관에서 일반촬영 검사의 피폭선량 연구", 한국방사선학회논문지, 5(5), pp.245~253 (2011), 한국방사선학회
  2. 신성규, "X-선관 각도 변경에 따른 Anode Heel Effect", 한국방사선학회논문지, 10(6), pp.435~442 (2016), 한국방사선학회[DOI]
  3. Radiation Instruments Research Society, "Radiation equipment" (2019), Cheong-Ku Munhwasa
  4. Kim HJ, "Medical imaging informatics" (2020), Cheong-Ku Munhwasa
  5. Kang SS, "Textbook of radiographic positioning and clinical diagnosis" (2013), Cheong-Ku Munhwasa
  6. Standard imaging technique in radiology examination (general imaging), "Wang JH", Korea Centers for Disease Control and Prevention, ~ (2014)
  7. 박정호, "경추 사방향 검사에서 전후면과 후전면 자세에 따른 갑상선 표면선량 비교", 방사선기술과학, 40(4), pp.543~548 (2017), 대한방사선과학회[DOI]
  8. Kang SS, "Radiation biology" (2019), Cheong-Ku Munhwasa
  9. Park YS, "Radioblology" (2019), Jeong-Mun Kag
  10. 장근조, "양극의 경사각 효과에 따른 조사야 Xㅡ선 강도 분포", 한국방사선학회논문지, 5(5), pp.223~229 (2011), 한국방사선학회
  11. Ko SK, "Radiation equipment" (1998), Dae-Hak Seolim
  12. Kim SH, "Evaluation of dose and image quality according to heel effect of diagnostic radiation generator", master’s, Department of Radiological Science, pp.2020
  13. Shin JW, "Study on research for reducing radiation dose of head and neck for cephalometric radiography system", Journal of The Korean Society of Radiology, 9(2), pp.133~136 (2015)
  14. Kang MH, "A study for dose difference of anode and cathode by the size of radiation field in normal chest X-ray examination", Journal of The Korean Society of Radiology, 8(1), pp.113~115 (2014)
  15. 김계홍, "Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target", 의학물리, 27(4), pp.272~276 (2016), 한국의학물리학회[DOI]
  16. 최우철, "방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가", 방사선기술과학, 44(1), pp.53~58 (2021), 대한방사선과학회

관련 논문AI추천

두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향김동환, 김은혜, 김한용, 주영철대한방사선과학회 · Journal of Radiological Science and Technology2022 · 제45권 제6호유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가정홍량대한방사선과학회 · Journal of Radiological Science and Technology2021 · 제44권 제5호진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구김은혜, 김정수, 박혜민, 윤용수, 정회원대한방사선과학회 · Journal of Radiological Science and Technology2021 · 제44권 제6호A Study on the Evaluation of Exposure Dose and Image Quality as a Function of Exposure Conditions in Head Radiography for Children공창기, 박용순, 최성현(사)한국방사선산업학회 · 방사선산업학회지2020 · 제14권 제3호두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구이윤, 김기원, 민정환, 오주영, 이상선, 이영봉, 임경환대한방사선과학회 · Journal of Radiological Science and Technology2023 · 제46권 제2호자동노출조절장치를 이용한 흉부 방사선검사 시 갑상샘 장기선량 최소화를 위한 새로운 차폐 방법에 관한 연구주영철, 한범희, 홍동희대한방사선과학회 · Journal of Radiological Science and Technology2020 · 제43권 제5호

이 간행물의 다른 논문 (13건)