Purpose: The purpose of this study was to compare the biomechanical outcome in the mandibular posterior region between two different loading conditions by finite element analysis. Materials and Methods: The mandibular posterior teeth model and the implant model were generated for the study. And 2 different types of loading conditions were provided: Arbitrary occlusion and natural occlusion obtained from the digital occlusal analyzer, Accura (Accura, Dmetec Co. Ltd., Seoul, Korea). Total load of 100 N was evenly distributed over arbitrary occlusion points, and 100 N load was differentially distributed over natural occlusion points according to Accura data. The biomechanical outcome was evaluated by the finite element analysis software. Results: The result of finite element analysis showed considerable difference in both von Mises stress pattern and displacement under different loading conditions. Conclusion: In finite element analysis, it is recommended to simulate a realistic occlusal loading pattern that is based on accurate measurement. (J Dent Rehabil Appl Sci 2020;36(2):112-20)

Abstract

Purpose: The purpose of this study was to compare the biomechanical outcome in the mandibular posterior region between two different loading conditions by finite element analysis. Materials and Methods: The mandibular posterior teeth model and the implant model were generated for the study. And 2 different types of loading conditions were provided: Arbitrary occlusion and natural occlusion obtained from the digital occlusal analyzer, Accura (Accura, Dmetec Co. Ltd., Seoul, Korea). Total load of 100 N was evenly distributed over arbitrary occlusion points, and 100 N load was differentially distributed over natural occlusion points according to Accura data. The biomechanical outcome was evaluated by the finite element analysis software. Results: The result of finite element analysis showed considerable difference in both von Mises stress pattern and displacement under different loading conditions. Conclusion: In finite element analysis, it is recommended to simulate a realistic occlusal loading pattern that is based on accurate measurement. (J Dent Rehabil Appl Sci 2020;36(2):112-20)

참고문헌 (39)

  1. Geng JP, "Application of finite element analysis in implant dentistry : a review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)
  2. DeTolla DH, "Role of the finite element model in dental implants", J Oral Implantol, 26, pp.77~81 (2000)
  3. Trivedi S, "Finite element analysis : a boon to dentistry", J Oral Biol Craniofac Res, 4, pp.200~203 (2014)
  4. Shetty P, "Finite element method-an effective research tool for dentistry", J Clin Pediatr Dent, 34, pp.281~285 (2010)
  5. Eskitascioglu G, "The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone : a three-dimensional finite element study", J Prosthet Dent, 91, pp.144~150 (2004)
  6. Hernández-Vázquez RA, "Numerical analysis of masticatory forces on a lower first molar considering the contact between dental tissues", Appl Bionic Biomech, 2018, pp.4196343~ (2018)
  7. Benazzi S, "Comparison of occlusal loading conditions in a lower second premolar using three-dimensional finite element analysis", Clin Oral Investig, 18, pp.369~375 (2014)
  8. Brune A, "The effect of different occlusal contact situations on peri-implant bone stress-a contact finite element analysis of indirect axial loading", Mater Sci Eng C Mater Biol Appl, 99, pp.367~373 (2019)
  9. Röehrle O, "Occlusal loading during biting from an experimental and simulation point of view", Dent Mater, 34, pp.58~68 (2018)
  10. Chang Y, "Finite element analysis of dental implants with validation : to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process", Int J Implant Dent, 4, pp.7~ (2018)
  11. De Jager N, "The influence of different core material on the FEA-determined stress distribution in dental crowns", Dent Mater, 22, pp.234~242 (2006)
  12. Kondo T, "Influence of molar support loss on stress and strain in premolar periodontium : a patient-specific FEM study", J Dent, 37, pp.541~548 (2009)
  13. Rand A, "The effect of direct and indirect force transmission on peri-implant bone stress-a contact finite element analysis", Comput Methods Biomech Biomed Engin, 20, pp.1132~1139 (2017)
  14. Cailleteau JG, "A comparison of intracanal stresses in a post-restored tooth utilizing the finite element method", J Endodont, 18, pp.540~544 (1992)
  15. Papavasiliou G, "Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support prosthesis type and loading during function", J Prosthet Dent, 76, pp.633~640 (1996)
  16. Ausiello P, "Effect of adhesive layer properties on stress distribution in composite restorations-a 3D finite element analysis", Dent Mater, 18, pp.295~303 (2002)
  17. Eskitascioglu G, "The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone : a three-dimensional finite element study", J Prosthet Dent, 91, pp.144~150 (2004)
  18. Lanza A, "3D FEA of cemented steel glass and carbon posts in a maxillary incisor", Dent Mater, 21, pp.709~715 (2005)
  19. Mozayek RS, "Efficacy of adding a supporting implant in stress distribution of long-span fixed partial dentures : a 3D finite element analysis", J Dent Res Dent Clin Dent Prospects, 10, pp.81~86 (2016)
  20. 정민영, "Comparison of two computerized occlusal analysis systems for indicating occlusal contacts", The Journal of Advanced of Prosthodontics, 12(2), pp.49~54 (2020), 대한치과보철학회[DOI]
  21. Coolidge ED, "The thickness of the human periodontal membrane", J Am Dent Assoc, 24, pp.1260~1270 (1937)
  22. Yoshida N, "In vivo measurement of the elastic modulus of the human periodontal ligament", Med Eng Phy, 23, pp.567~572 (2001)
  23. Cattaneo PM, "The finite element method : a tool to study orthodontic tooth movement", J Dent Res, 84, pp.428~433 (2005)
  24. Moroi HH, "Numeric approach to the biomechanical analysis of thermal effects in coated implants", Int J Prosthodont, 6, pp.564~572 (1993)
  25. Sano H, "Tensile properties of mineralized and demineralized human and bovine dentin", J Dent Res, 73, pp.1205~1211 (1994)
  26. Farah JW, "Finite element analysis of three-and four-unit bridges", J Oral Rehabil, 16, pp.603~611 (1989)
  27. Jones ML, "A validated finite element method study of orthodontic tooth movement in the human subject", J Orthod, 28, pp.29~38 (2001)
  28. Tanne K, "An evaluation of the biomechanical response of the tooth and periodontium to orthodontic forces in adolescent and adult subjects", Br J Orthod, 25, pp.109~115 (1998)
  29. Toms SR, "A nonlinear finite element analysis of the periodontal ligament under orthodontic tooth loading", Am J Orthod Dentofacial Orthop, 123, pp.657~665 (2003)
  30. Jung WK, "Effects of abutment screw preload in two implant connection systems : a 3D finite element study", J Prosthet Dent, 122, pp.474.e1~474.e8 (2019)
  31. Silva GC, "Biomechanical evaluation of screw-and cement-retained implant-supported prostheses : a nonlinear finite element analysis", J Prosthet Dent, 112, pp.1479~1488 (2014)
  32. Quaresma SET, "A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone", J Oral Implantol, 34, pp.1~6 (2008)
  33. Wataha JC, "Alloys for prosthodontic restorations", J Prosthet Dent, 87, pp.351~363 (2002)
  34. Jörn D, "Influence of lubricant on screw preload and stresses in a finite element model for a dental implant", J Prosthet Dent, 112, pp.340~348 (2014)
  35. Inzana JA, "Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems", J Biomech, 49, pp.1836~1844 (2016)
  36. Hsu ML, "Influence of off-axis loading of an anterior maxillary implant : a 3-dimensional finite element analysis", Int J Oral Maxillofac Implants, 22, pp.301~309 (2007)
  37. Chang CL, "Finite element analysis of the dental implant using a topology optimization method", Med Eng Phys, 34, pp.999~1008 (2012)
  38. Martin WC, "Implant abutment screw rotations and preloads for four different screw materials and surfaces", J Prosthet Dent, 86, pp.24~32 (2011)
  39. Lang LA, "Finite element analysis to determine implant preload", J Prosthet Dent, 90, pp.539~546 (2003)

관련 논문AI추천

Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis박찬, 박상원, 양홍서, 윤귀덕, 임현필, 정현주대한턱관절교합학회 · 구강회복응용과학지2020 · 제36권 제3호Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis studyParamba Hitendrabhai Acharya, Sareen Subhash Duseja, Vilas Valjibhai Patel, Vishal Rajendrabhai Chauhan대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element studyAngel Alvarez-Arenal, Aritza Brizuela-Velasco, Elena Martin-Fernandez, Hector deLlanos-Lanchares, Ignacio Gonzalez-Gonzalez, Joseba Ellacuria-Echebarria대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysisAli Riza Tuncdemir, Nilgün Gulbahce Yesilyurt대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제4호Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses곽재영, 김성균, 손병섭, 이수영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호하악 구치부에서 임플란트 고정체와 지대주의 협설 기울기에 따른 응력분포에 관한 삼차원 유한요소 분석김명래, 김선종, 김예미, 김지연, 이현숙대한턱관절교합학회 · 구강회복응용과학지2011 · 제27권 제4호

이 간행물의 다른 논문 (9건)