An evaluation of the stress effect of different occlusion concepts on hybrid abutment and implant supported monolithic zirconia fixed prosthesis: A finite element analysis
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA). MATERIALS AND METHODS. This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Threedimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15º and 30º under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis. RESULTS. Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force. CONCLUSION. The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.
Abstract
PURPOSE. The aim of this study is to evaluate the effects of canine guidance occlusion and group function occlusion on the degree of stress to the bone, implants, abutments, and crowns using finite element analysis (FEA). MATERIALS AND METHODS. This study included the implant-prosthesis system of a three-unit bridge made of monolithic zirconia and hybrid abutments. Threedimensional (3D) models of a bone-level implant system and a titanium base abutment were created using the original implant components. Two titanium implants, measuring 4 × 11 mm each, were selected. The loads were applied in two oblique directions of 15º and 30º under two occlusal movement conditions. In the canine guidance condition, loads (100 N) were applied to the canine crown only. In the group function condition, loads were applied to all three teeth. In this loading, a force of 100 N was applied to the canine, and 200-N forces were applied to each premolar. The stress distribution among all the components of the implant-bridge system was assessed using ANSYS SpaceClaim 2020 R2 software and finite element analysis. RESULTS. Maximum stress was found in the group function occlusion. The maximum stress increased with an increase in the angle of occlusal force. CONCLUSION. The canine guidance occlusion with monolithic zirconia crown materials is promising for implant-supported prostheses in the canine and premolar areas.
참고문헌 (41)
- Reddy MS, "Application of finite element model in implant dentistry : a systematic review", J Pharm Bioallied Sci, 11, pp.S85~S91 (2019)
- Datte CE, "Influence of different restorative materials on the stress distribution in dental implants", J Clin Exp Dent, 10, pp.e439~e444 (2018)
- Guess PC, "Zirconia in fixed implant prosthodontics", Clin Implant Dent Relat Res, 14, pp.633~645 (2012)
- Zhang Y, "Evaluating dental zirconia", Dent Mater, 35, pp.15~23 (2019)
- Lops D, "Influence of abutment material on peri-implant soft tissues in anterior areas with thin gingival biotype : a multicentric prospective study", Clin Oral Implants Res, 28, pp.1263~1268 (2017)
- Molina A, "The effect of one-time abutment placement on interproximal bone levels and peri-implant soft tissues : a prospective randomized clinical trial", Clin Oral Implants Res, 28, pp.443~452 (2017)
- Yildirim M, "In vivo fracture resistance of implant-supported all-ceramic restorations", J Prosthet Dent, 90, pp.325~331 (2003)
- Egilmez Ferhat, "Zirconia ceramics and their use in dental implantology", Cumhuriyet Dent J, 13, pp.72~80 (2010)
- Conejo J, "Performance of CAD", CAM monolithic ceramic Implant-supported restorations bonded to titanium inserts : a systematic review, 2017, pp.10, 139~146
- Swaminathan Y, "Implant protected occlusion", IOSR J Dent Med Sci, 11, pp.20~25 (2013)
- Tribst JPM, "Influence of implant connection on the stress distribution in restorations performed with hybrid abutments", J Osseointegration, 11, pp.507~512 (2019)
- Verma M, "Principles of occlusion in implant dentistry", J Int Clin Dent Res Organ, 7, pp.27~33 (2015)
- Delgado-Ruiz RA, "Ef-fects of occlusal forces on the peri-implant-bone interface stability", Periodontol 2000, 81, pp.179~193 (2019)
- Graves CV, "The role of occlusion in the dental implant and peri-implant condition : a review", Open Dent J, 10, pp.594~601 (2016)
- Sheridan RA, "The role of occlusion in implant therapy : a comprehensive updated review", Implant Dent, 25, pp.829~838 (2016)
- Chang Y, "Finite element analysis of dental implants with validation : to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process", Int J Implant Dent, 4, pp.7~ (2018)
- Stanley JN, "Wheeler’s dental anatomy, physiology and occlusion", pp.13~ (2019), Elsevier-Health Science
- Robati Anaraki M, "Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns : a finite element analysis", J Dent Res Dent Clin Dent Prospects, 13, pp.90~97 (2019)
- Gungor MA, "The effect of margin design on stress distribution on all-ceramic materials : a finite element", Ege Univ Faculty Dent J, 26, pp.145~153 (2005)
- de la Rosa Castolo G, "Mechanical strength and fracture point of a dental implant under certification conditions : a numerical approach by finite element analysis", J Prosthet Dent, 119, pp.611~619 (2018)
- Cattaneo PM, "The finite element method : a tool to study orthodontic tooth movement", J Dent Res, 84, pp.428~433 (2005)
- Göre E, "Assessment of the effect of two occlusal concepts for implant-supported fixed prostheses by finite element analysis in patients with bruxism", J Oral Implantol, 40, pp.68~75 (2014)
- Lin D, "Dental implant induced bone remodeling and associated algorithms", J Mech Behav Biomed Mater, 2, pp.410~432 (2009)
- Bankoğlu Güngör M, "Evaluation of stress distributions occurring on zirconia and titanium implant-supported prostheses : a three-dimensional finite element analysis", J Prosthet Dent, 116, pp.346~355 (2016)
- DeTolla DH, "Role of the finite element model in dental implants", J Oral Implantol, 26, pp.77~81 (2000)
- Geng JP, "Application of finite element analysis in implant dentistry : a review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)
- Srirekha A, "Infinite to finite : an overview of finite element analysis", Indian J Dent Res, 21, pp.425~432 (2010)
- Fanuscu MI, "Implant biomechanics in grafted sinus : a finite element analysis", J Oral Implantol, 30, pp.59~68 (2004)
- Pesqueira AA, "Use of stress analysis methods to evaluate the biomechanics of oral rehabilitation with implants", J Oral Implantol, 40, pp.217~228 (2014)
- Rezende CE, "Stress distribution in single dental implant system : three-dimensional finite element analysis based on an in vitro experimental model", J Craniofac Surg, 26, pp.2196~2200 (2015)
- Morneburg TR, "In vivo forces on implants influenced by occlusal scheme and food consistency", Int J Prosthodont, 16, pp.481~486 (2003)
- Wood MR, "A review of selected dental literature on evidence-based treatment planning for dental implants:report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics", J Prosthet Dent, 92, pp.447~462 (2004)
- Koyano K, "Occlusion on oral implants : current clinical guidelines", J Oral Rehabil, 42, pp.153~161 (2015)
- Engel E, "Effect of occlusal wear on bone loss and Periotest value of dental implants", Int J Prosthodont, 14, pp.444~450 (2001)
- Brägger U, "Biological and technical complications and failures with fixed partial dentures(FPD)on implants and teeth after four to five years of function", Clin Oral Implants Res, 12, pp.26~34 (2001)
- Kim Y, "Occlusal considerations in implant therapy : clinical guidelines with biomechanical rationale", Clin Oral Implants Res, 16, pp.26~35 (2005)
- Leja W, "Non-carious cervical lesions in relation to the occlusion type and the inclination of the individual guiding elements", Germany Dent J, 54, pp.412~414 (1999)
- Tokiwa O, "Relationship of tooth grinding pattern during sleep bruxism and dental status", Cranio, 26, pp.287~293 (2008)
- Misch CE, "Using implant positions : treatment planning canine and first molar rules", Dent Today, 28, pp.66~ (2009)
- Misch CE, "Dental implant prosthetics", pp.15~ (2005), Elsevier Mosby
- Christensen GJ, "Now is the time to observe and treat dental occlusion", J Am Dent Assoc, 132, pp.100~102 (2001)
