본문 바로가기
KERD
논문KCI 등재

Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.

Abstract

This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.

참고문헌 (34)

  1. Zilberman O, "Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models", Angle Orthod, 73, pp.301~306 (2003)
  2. Rheude B, "An evaluation of the use of digital study models in orthodontic diagnosis and treatment planning", Angle Orthod, 75, pp.300~304 (2005)
  3. Fleming PS, "Orthodontic measurements on digital study models compared with plaster models : a systematic review", Orthod Craniofac Res, 14, pp.1~16 (2011)
  4. Bosoni C, "Comparison between digital and conventional impression techniques in children on preference, time and comfort : A crossover randomized controlled trial", Orthod Craniofac Res, 26, pp.585~590 (2023)
  5. Dixit UB, "The use of interactive distraction technique to manage gagging during impression taking in children : a single-blind, randomised controlled trial", Eur Arch Paediatr Dent, 22, pp.219~225 (2021)
  6. Stevens DR, "Validity, reliability, and reproducibility of plaster vs digital study models : comparison of peer assessment rating and Bolton analysis and their constituent measurements", Am J Orthod Dentofacial Orthop, 129, pp.794~803 (2006)
  7. Naidu D, "The evidence supporting methods of tooth width measurement: Part II. Digital models and intra-oral scanners", Aust Orthod J, 29, pp.164~169 (2013)
  8. Rossini G, "Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes : A systematic review", Am J Orthod Dentofacial Orthop, 149, pp.161~170 (2016)
  9. Mangano A, "Conventional Vs Digital Impressions : Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients", Open Dent J, 12, pp.118~124 (2018)
  10. Burhardt L, "Treatment comfort, time perception, and preference for conventional and digital impression techniques : A comparative study in young patients", Am J Orthod Dentofacial Orthop, 150, pp.261~267 (2016)
  11. Naidu D, "The evidence supporting methods of tooth width measurement: Part I. Vernier calipers to stereophotogrammetry", Aust Orthod J, 29, pp.159~163 (2013)
  12. Singh S, "Estimation of the Intercanine Width, Intermolar Width, Arch Length, and Arch Perimeter and Its Comparison in 12-17-year-old Children of Faridabad", Int J Clin Pediatr Dent, 14, pp.369~375 (2021)
  13. Yilmaz H, "Digital versus conventional impression method in children : Comfort, preference and time", Int J Paediatr Dent, 29, pp.728~735 (2019)
  14. Kardach H, "A Comparison of Teeth Measurements on Plaster and Digital Models", J Clin Med, 12, pp.943~ (2023)
  15. Gierie WV, "Clear aligner therapy : An overview", J Clin Orthod, 52, pp.665~674 (2018)
  16. Hwang HH, "An overview of digital intraoral scanners : Past, present and future-from an orthodontic perspective", Taiwan J Orthodont, 30, pp.148~162 (2018)
  17. Shailendran A, "Accuracy and reliability of tooth widths and Bolton ratios measured by ClinCheck Pro", Am J Orthod Dentofacial Orthop, 161, pp.65~73 (2022)
  18. Adobes Martin M, "Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6. 0 Software on Digital Casts : A Cross-Sectional Study", Int J Environ Res Public Health, 19, pp.3581~ (2022)
  19. Soto-Álvarez C, "Reliability, reproducibility and validity of the conventional buccolingual and mesiodistal measurements on 3D dental digital models obtained from intra-oral 3D scanner", Arch Oral Biol, 109, pp.104575~ (2020)
  20. Rajshekar M, "The reliability and validity of measurements of human dental casts made by an intra-oral 3D scanner, with conventional hand-held digital callipers as the comparison measure", Forensic Sci Int, 278, pp.198~204 (2017)
  21. Rosseto MC, "Comparative study of dental arch width in plaster models, photocopies and digitized images", Braz Oral Res, 23, pp.190~195 (2009)
  22. Im J, "Comparison of virtual and manual tooth setups with digital and plaster models in extraction cases", Am J Orthod Dentofacial Orthop, 145, pp.434~442 (2014)
  23. Watanabe-Kanno GA, "Reproducibility, reliability and validity of measurements obtained from Cecile3digital models", Braz Oral Res, 23, pp.288~295 (2009)
  24. Quimby ML, "The accuracy and reliability of measurements made on computer-based digital models", Angle Orthod, 74, pp.298~303 (2004)
  25. Leifert MF, "Comparison of space analysis evaluations with digital models and plaster dental casts", Am J Orthod Dentofacial Orthop, 136, pp.16~ (2009)
  26. Goonewardene RW, "Accuracy and validity of space analysis and irregularity index measurements using digital models", Aust Orthod J, 24, pp.83~90 (2008)
  27. Mullen SR, "Accuracy of space analysis with emodels and plaster models", Am J Orthod Dentofacial Orthop, 132, pp.346~352 (2007)
  28. Redlich M, "A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor", Orthod Craniofac Res, 11, pp.90~95 (2008)
  29. Schirmer UR, "Manual and computer-aided space analysis : a comparative study", Am J Orthod Dentofacial Orthop, 112, pp.676~680 (1997)
  30. De Luca Canto G, "Intra-arch dimensional measurement validity of laser-scanned digital dental models compared with the original plaster models : a systematic review", Orthod Craniofac Res, 18, pp.65~76 (2015)
  31. Santoro M, "Mesiodistal crown dimensions and tooth size discrepancy of the permanent dentition of Dominican Americans", Angle Orthod, 70, pp.303~307 (2000)
  32. Uysal T, "Intermaxillary tooth size discrepancy and mesiodistal crown dimensions for a Turkish population", Am J Orthod Dentofacial Orthop, 128, pp.226~230 (2005)
  33. McNamara JA Jr, "Early intervention in the transverse dimension : is it worth the effort?", Am J Orthod Dentofacial Orthop, 121, pp.572~574 (2002)
  34. Grünheid T, "Accuracy, reproducibility, and time efficiency of dental measurements using different technologies", Am J Orthod Dentofacial Orthop, 145, pp.157~164 (2014)

관련 논문AI추천

Accuracy of inter-arch measurements performed on digital models generated using two types of intraoral scanners: Ex vivo study김성훈, 문철현, 유조광, Su-Jung Lee, Yoon-Koo Kang대한치과의사협회 · 대한치과의사협회지2020 · 제58권 제4호Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differencesChoi Won-joon, Lee Su-jung, Moon Cheol-Hyun대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제1호Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scannersAnne Marie Kuijpers-Jagtman, Edwin M. Ongkosuwito, E. Willemijn Penning, K. Hero Breuning, Leonardo T. Camardella, Oswaldo V. Vilella대한치과교정학회 · 대한치과교정학회지2020 · 제50권 제1호모델 스캐너와 구내 스캐너로 획득한 디지털 모형에서 시행한 공간 분석의 타당도, 신뢰도, 재현성 평가김종수, 박서현, 오소희대한소아치과학회 · 대한소아치과학회지2020 · 제47권 제2호Predictability of maxillary dentoalveolar expansion with clear aligners in patients with mixed dentitionAlessandro Bruni, Andrea Piero Deregibus, Georgios Litsas, Giovanni Cugliari, Simone Parrini, Tommaso Castroflorio, Vittorio Gallo대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제2호A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning directionJi-Man Park, Ji-won Anh, Miae Kim, Minji Kima, Youn-Sic Chun대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제1호

이 간행물의 다른 논문 (9건)